Research of the composition of oxide layer and corn of the klystron cathodes with different degree of development

In accordance with the work program for the restoration of klystrons, a cycle of studies was carried out, which includes X-ray fluorescence analysis of the composition of the emitter layer and core of oxide cathodes with different degrees of operating time. Studies have been conducted to assess the...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2019
Автори: Vangha, S.O., Dronov, R.M., Mats, V.O., Medvediev, O.V., Tytov, V.Yu., Tur, Yu.D., Chayka, I.O., Yaroshenko, E.A.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2019
Назва видання:Вопросы атомной науки и техники
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/195233
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Research of the composition of oxide layer and corn of the klystron cathodes with different degree of development / S.O. Vangha, R.M. Dronov, V.O. Mats, O.V. Medvediev, V.Yu. Tytov, Yu.D. Tur, I.O. Chayka, E.A. Yaroshenko // Problems of atomic science and technology. — 2019. — № 6. — С. 27-31. — Бібліогр.: 4 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Опис
Резюме:In accordance with the work program for the restoration of klystrons, a cycle of studies was carried out, which includes X-ray fluorescence analysis of the composition of the emitter layer and core of oxide cathodes with different degrees of operating time. Studies have been conducted to assess the possibility of using and predicting the resource, both restored and used cathodes. Studies were conducted to assess the possibility of using and predicting the resource, both restored and used cathodes. The analysis was performed using a Bruker S8 TIGER WDXRF spectrometer (X-ray tube power 4 kW, Rh-cathode, current up to 170 mA, voltage up to 60 kV), with Spectra Plus software package. Comparative analysis of the data obtained for emitters with different degrees of development can provide a fairly reliable estimate of the efficiency and resource of the cathodes.