Development of a portable gamma probe for registration and localization of radiation source, including medical application

Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Tes...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2023
Автори: Kapliy, O.A., Kiprich, S.K., Kovalenko, G.D., Ovchinnik, V.D., Shirokopetlev, F.O., Shlyakhov, I.M., Shulika, M.Yu., Vasiliev, G.P., Yalovenko, V.I.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2023
Назва видання:Problems of Atomic Science and Technology
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/196139
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-196139
record_format dspace
spelling irk-123456789-1961392023-12-10T18:52:28Z Development of a portable gamma probe for registration and localization of radiation source, including medical application Kapliy, O.A. Kiprich, S.K. Kovalenko, G.D. Ovchinnik, V.D. Shirokopetlev, F.O. Shlyakhov, I.M. Shulika, M.Yu. Vasiliev, G.P. Yalovenko, V.I. Detectors and nuclear radiation detection Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Test stand was developed for determining the angular resolution of the gamma probe. На базі кремнієвого планарного неохолоджуваного детектора і сцинтилятора СsI(Tl) розроблений портативний гамма-зонд з автономним живленням. Прилад розрахований на інтероперативний та екстраоперативний пошуки відмінностей у концентрації радіофармацевтичних препаратів у енергетичному діапазоні 100 до 360 кеВ. Розроблено тестовий стенд для визначення кутового розподілу гамма-зонда. 2023 Article Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ. 1562-6016 PACS: 07.85.Nc, 07.05.Hd DOI: https://doi.org/10.46813/2023-145-056 http://dspace.nbuv.gov.ua/handle/123456789/196139 en Problems of Atomic Science and Technology Національний науковий центр «Харківський фізико-технічний інститут» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Detectors and nuclear radiation detection
Detectors and nuclear radiation detection
spellingShingle Detectors and nuclear radiation detection
Detectors and nuclear radiation detection
Kapliy, O.A.
Kiprich, S.K.
Kovalenko, G.D.
Ovchinnik, V.D.
Shirokopetlev, F.O.
Shlyakhov, I.M.
Shulika, M.Yu.
Vasiliev, G.P.
Yalovenko, V.I.
Development of a portable gamma probe for registration and localization of radiation source, including medical application
Problems of Atomic Science and Technology
description Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Test stand was developed for determining the angular resolution of the gamma probe.
format Article
author Kapliy, O.A.
Kiprich, S.K.
Kovalenko, G.D.
Ovchinnik, V.D.
Shirokopetlev, F.O.
Shlyakhov, I.M.
Shulika, M.Yu.
Vasiliev, G.P.
Yalovenko, V.I.
author_facet Kapliy, O.A.
Kiprich, S.K.
Kovalenko, G.D.
Ovchinnik, V.D.
Shirokopetlev, F.O.
Shlyakhov, I.M.
Shulika, M.Yu.
Vasiliev, G.P.
Yalovenko, V.I.
author_sort Kapliy, O.A.
title Development of a portable gamma probe for registration and localization of radiation source, including medical application
title_short Development of a portable gamma probe for registration and localization of radiation source, including medical application
title_full Development of a portable gamma probe for registration and localization of radiation source, including medical application
title_fullStr Development of a portable gamma probe for registration and localization of radiation source, including medical application
title_full_unstemmed Development of a portable gamma probe for registration and localization of radiation source, including medical application
title_sort development of a portable gamma probe for registration and localization of radiation source, including medical application
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2023
topic_facet Detectors and nuclear radiation detection
url http://dspace.nbuv.gov.ua/handle/123456789/196139
citation_txt Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ.
series Problems of Atomic Science and Technology
work_keys_str_mv AT kapliyoa developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT kiprichsk developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT kovalenkogd developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT ovchinnikvd developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT shirokopetlevfo developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT shlyakhovim developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT shulikamyu developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT vasilievgp developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
AT yalovenkovi developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication
first_indexed 2024-03-31T09:18:54Z
last_indexed 2024-03-31T09:18:54Z
_version_ 1796158129213276160