Development of a portable gamma probe for registration and localization of radiation source, including medical application
Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Tes...
Збережено в:
Дата: | 2023 |
---|---|
Автори: | , , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2023
|
Назва видання: | Problems of Atomic Science and Technology |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/196139 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-196139 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-1961392023-12-10T18:52:28Z Development of a portable gamma probe for registration and localization of radiation source, including medical application Kapliy, O.A. Kiprich, S.K. Kovalenko, G.D. Ovchinnik, V.D. Shirokopetlev, F.O. Shlyakhov, I.M. Shulika, M.Yu. Vasiliev, G.P. Yalovenko, V.I. Detectors and nuclear radiation detection Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Test stand was developed for determining the angular resolution of the gamma probe. На базі кремнієвого планарного неохолоджуваного детектора і сцинтилятора СsI(Tl) розроблений портативний гамма-зонд з автономним живленням. Прилад розрахований на інтероперативний та екстраоперативний пошуки відмінностей у концентрації радіофармацевтичних препаратів у енергетичному діапазоні 100 до 360 кеВ. Розроблено тестовий стенд для визначення кутового розподілу гамма-зонда. 2023 Article Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ. 1562-6016 PACS: 07.85.Nc, 07.05.Hd DOI: https://doi.org/10.46813/2023-145-056 http://dspace.nbuv.gov.ua/handle/123456789/196139 en Problems of Atomic Science and Technology Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
topic |
Detectors and nuclear radiation detection Detectors and nuclear radiation detection |
spellingShingle |
Detectors and nuclear radiation detection Detectors and nuclear radiation detection Kapliy, O.A. Kiprich, S.K. Kovalenko, G.D. Ovchinnik, V.D. Shirokopetlev, F.O. Shlyakhov, I.M. Shulika, M.Yu. Vasiliev, G.P. Yalovenko, V.I. Development of a portable gamma probe for registration and localization of radiation source, including medical application Problems of Atomic Science and Technology |
description |
Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Test stand was developed for determining the angular resolution of the gamma probe. |
format |
Article |
author |
Kapliy, O.A. Kiprich, S.K. Kovalenko, G.D. Ovchinnik, V.D. Shirokopetlev, F.O. Shlyakhov, I.M. Shulika, M.Yu. Vasiliev, G.P. Yalovenko, V.I. |
author_facet |
Kapliy, O.A. Kiprich, S.K. Kovalenko, G.D. Ovchinnik, V.D. Shirokopetlev, F.O. Shlyakhov, I.M. Shulika, M.Yu. Vasiliev, G.P. Yalovenko, V.I. |
author_sort |
Kapliy, O.A. |
title |
Development of a portable gamma probe for registration and localization of radiation source, including medical application |
title_short |
Development of a portable gamma probe for registration and localization of radiation source, including medical application |
title_full |
Development of a portable gamma probe for registration and localization of radiation source, including medical application |
title_fullStr |
Development of a portable gamma probe for registration and localization of radiation source, including medical application |
title_full_unstemmed |
Development of a portable gamma probe for registration and localization of radiation source, including medical application |
title_sort |
development of a portable gamma probe for registration and localization of radiation source, including medical application |
publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
publishDate |
2023 |
topic_facet |
Detectors and nuclear radiation detection |
url |
http://dspace.nbuv.gov.ua/handle/123456789/196139 |
citation_txt |
Development of a portable gamma probe for registration and localization of radiation source, including medical application / O.A. Kapliy, S.K. Kiprich, G.D. Kovalenko, V.D. Ovchinnik, F.O. Shirokopetlev, I.M. Shlyakhov, M.Yu. Shulika, G.P. Vasiliev, V.I. Yalovenko // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 56-58. — Бібліогр.: 9 назв. — англ. |
series |
Problems of Atomic Science and Technology |
work_keys_str_mv |
AT kapliyoa developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT kiprichsk developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT kovalenkogd developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT ovchinnikvd developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT shirokopetlevfo developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT shlyakhovim developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT shulikamyu developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT vasilievgp developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication AT yalovenkovi developmentofaportablegammaprobeforregistrationandlocalizationofradiationsourceincludingmedicalapplication |
first_indexed |
2024-03-31T09:18:54Z |
last_indexed |
2024-03-31T09:18:54Z |
_version_ |
1796158129213276160 |