On a possibility of nondisturbing monitoring of electron-radiation absorbed dose in radiation-technological processes
Great deals of present-day radiation technologies that use electron accelerators involve the procedure of transporting the products under treatment across the irradiation zone normally to the beam scanning plane. The main controlled characteristic of the process is the electron radiation dose abso...
Збережено в:
Дата: | 2006 |
---|---|
Автори: | , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/78851 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | On a possibility of nondisturbing monitoring of electron-radiation absorbed dose in radiation-technological processes / S.P. Karasyov, V.I. Nikiforov, R.I. Pomatsalyuk, A.Eh. Tenishev, V.L. Uvarov, V.A. Shevchenko, I.N. Shlyakhov, E.B. Malets // Вопросы атомной науки и техники. — 2006. — № 2. — С. 201-203. — Бібліогр.: 3 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of UkraineРезюме: | Great deals of present-day radiation technologies that use electron accelerators involve the procedure of transporting
the products under treatment across the irradiation zone normally to the beam scanning plane. The main controlled
characteristic of the process is the electron radiation dose absorbed in the object under treatment. The present
paper offers the method of nonperturbing real-time dose and electron energy monitoring. The method is based on
the analysis of distribution of currents from the plates of a sectionalized beam charge absorber. The absorber is
placed behind the conveyor and is periodically shut off from the beam by the object under irradiation. The method
was preliminarily analyzed through computer simulation. |
---|