An electron miniaccelerator on the basis of Tesla transformer for nondestructive testing of charged particle beams
An electron miniaccelerator on the basis of Tesla-transformer for nondestructive testing of charged particle beams with operating voltage 120…200 kV, half-wave duration 4 mks and diagnostic beam current within few mA is described. The primary circuit is switched by IGBT. The gun control and filame...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
Series: | Вопросы атомной науки и техники |
Subjects: | |
Online Access: | http://dspace.nbuv.gov.ua/handle/123456789/78856 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An electron miniaccelerator on the basis of Tesla-transformer for nondestructive testing of charged particle
beams with operating voltage 120…200 kV, half-wave duration 4 mks and diagnostic beam current within few mA
is described. The primary circuit is switched by IGBT. The gun control and filament circuit power supply (impregnated
cathode with 1.2 mm diameter) are realized through high frequency isolated transformer. The accelerating
tube is made of sectional welded metal ceramics insulator (ceramics 22HS with diameter 95/85 mm).The accelerator
test results are presented. |
---|