Beam forming system modernization at the MMF linac proton injector
The isolation improvements of the beam forming system (BFS) of the ММF linac proton injector ion source are reported. The mean beam current and, accordingly, BFS electrode heating were increased when the ММF linac has began to operate regularly in long beam sessions with 50 Hz pulse repetition rate....
Збережено в:
Дата: | 2001 |
---|---|
Автори: | , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2001
|
Назва видання: | Вопросы атомной науки и техники |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/79020 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Beam forming system modernization at the MMF linac proton injector / V.I. Derbilov, S.K. Esin, E.S. Nikulin, O.T. Frolov, V.P. Yakushev // Вопросы атомной науки и техники. — 2001. — № 5. — С. 131-133. — Бібліогр.: 6 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-79020 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-790202015-03-25T03:02:28Z Beam forming system modernization at the MMF linac proton injector Derbilov, V.I. Esin, S.K. Nikulin, E.S. Frolov, O.T. Yakushev, V.P. The isolation improvements of the beam forming system (BFS) of the ММF linac proton injector ion source are reported. The mean beam current and, accordingly, BFS electrode heating were increased when the ММF linac has began to operate regularly in long beam sessions with 50 Hz pulse repetition rate. That is why the BFS electrode high-voltage isolation that was made previously as two consequently and rigidly glued solid cylinder insulators has lost mechanical and electric durability. The substitution of large (160 mm) diameter cylinder insulator for four small diameter (20 mm) tubular rods has improved vacuum conditions in the space of beam forming and has allowed to operate without failures when beam currents being up to 250 mA and extraction and focusing voltage being up to 25 and 40 kV respectively. Moreover, the construction provides the opportunity of electrode axial move. The insulators are free from electrode thermal expansion mechanical efforts in a transverse direction. 2001 Article Beam forming system modernization at the MMF linac proton injector / V.I. Derbilov, S.K. Esin, E.S. Nikulin, O.T. Frolov, V.P. Yakushev // Вопросы атомной науки и техники. — 2001. — № 5. — С. 131-133. — Бібліогр.: 6 назв. — англ. 1562-6016 PACS number: 29.17.+w http://dspace.nbuv.gov.ua/handle/123456789/79020 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
description |
The isolation improvements of the beam forming system (BFS) of the ММF linac proton injector ion source are reported. The mean beam current and, accordingly, BFS electrode heating were increased when the ММF linac has began to operate regularly in long beam sessions with 50 Hz pulse repetition rate. That is why the BFS electrode high-voltage isolation that was made previously as two consequently and rigidly glued solid cylinder insulators has lost mechanical and electric durability. The substitution of large (160 mm) diameter cylinder insulator for four small diameter (20 mm) tubular rods has improved vacuum conditions in the space of beam forming and has allowed to operate without failures when beam currents being up to 250 mA and extraction and focusing voltage being up to 25 and 40 kV respectively. Moreover, the construction provides the opportunity of electrode axial move. The insulators are free from electrode thermal expansion mechanical efforts in a transverse direction. |
format |
Article |
author |
Derbilov, V.I. Esin, S.K. Nikulin, E.S. Frolov, O.T. Yakushev, V.P. |
spellingShingle |
Derbilov, V.I. Esin, S.K. Nikulin, E.S. Frolov, O.T. Yakushev, V.P. Beam forming system modernization at the MMF linac proton injector Вопросы атомной науки и техники |
author_facet |
Derbilov, V.I. Esin, S.K. Nikulin, E.S. Frolov, O.T. Yakushev, V.P. |
author_sort |
Derbilov, V.I. |
title |
Beam forming system modernization at the MMF linac proton injector |
title_short |
Beam forming system modernization at the MMF linac proton injector |
title_full |
Beam forming system modernization at the MMF linac proton injector |
title_fullStr |
Beam forming system modernization at the MMF linac proton injector |
title_full_unstemmed |
Beam forming system modernization at the MMF linac proton injector |
title_sort |
beam forming system modernization at the mmf linac proton injector |
publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
publishDate |
2001 |
url |
http://dspace.nbuv.gov.ua/handle/123456789/79020 |
citation_txt |
Beam forming system modernization at the MMF linac proton injector / V.I. Derbilov, S.K. Esin, E.S. Nikulin, O.T. Frolov, V.P. Yakushev // Вопросы атомной науки и техники. — 2001. — № 5. — С. 131-133. — Бібліогр.: 6 назв. — англ. |
series |
Вопросы атомной науки и техники |
work_keys_str_mv |
AT derbilovvi beamformingsystemmodernizationatthemmflinacprotoninjector AT esinsk beamformingsystemmodernizationatthemmflinacprotoninjector AT nikulines beamformingsystemmodernizationatthemmflinacprotoninjector AT frolovot beamformingsystemmodernizationatthemmflinacprotoninjector AT yakushevvp beamformingsystemmodernizationatthemmflinacprotoninjector |
first_indexed |
2023-10-18T19:17:45Z |
last_indexed |
2023-10-18T19:17:45Z |
_version_ |
1796146528731004928 |