Target unit for radiation test of materials under bremsstrahlung of electron accelerator

There is a necessity to provide an immobilization of the long-lived radioactive waste into radiation-resistant structure (a cement matrix, container capsule, geological disposal environment and so on) for it safely disposal. The material of the every of these barriers should have resistance correspo...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2001
Автори: Yeran, L.V., Karasyov, S.P., Pomatsalyuk, R.I., Sayenko, S.Yu., Shevchenko, V.A., Shlyakhov, I.N., Tenishev, A.Eh., Uvarov, V.L.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2001
Назва видання:Вопросы атомной науки и техники
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/79031
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Target unit for radiation test of materials under bremsstrahlung of electron accelerator / L.V. Yeran, S.P. Karasyov, R.I. Pomatsalyuk, S.Yu. Sayenko, V.A. Shevchenko, I.N. Shlyakhov, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2001. — № 5. — С. 206-208. — Бібліогр.: 5 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Опис
Резюме:There is a necessity to provide an immobilization of the long-lived radioactive waste into radiation-resistant structure (a cement matrix, container capsule, geological disposal environment and so on) for it safely disposal. The material of the every of these barriers should have resistance corresponding to the absorbed dose value up to 10⁸ Gy for the period of time up to 1000 years. The method of imitation exposure of the materials under bremsstrahlung of the high-current Linac was developed for prediction behavior and material selection. For realization of this method in a wide range of exposure conditions (by temperature, humidity, rate and amount of the doze) the special target unit was designed. It has a modular construction and includes two chambers for samples (one for exposure in liquid and another one – in the atmosphere) that are placed along the irradiation axis and integrated together spatially. Also, the target unit has plane-parallel ionization chamber for continuous monitoring of the photon flux intensity and absorbed doze. The copper thermistor is used as a temperature probe. The structure and characteristics of measurement channels are described as well.