New 15 MeV electron accelerator for non-destructive testing

A 15 MeV accelerator with the dose rate from 80 to 120 Gy/min at 1m from the target has been designed and manufactured in NPK LUTS, the D.V.Efremov Institute, NIIEFA. The accelerator is intended for nondestructive testing (radiography, introscopy, tomography) of large scale products. Under tests an...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2001
Автори: Vorogushin, M.F., Gavrish, Yu.N., Nikolaev, V.M., Muratov, A.V., Klinov, A.P., Ryabtsov, A.V.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2001
Назва видання:Вопросы атомной науки и техники
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/79215
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:New 15 MeV electron accelerator for non-destructive testing / M.F. Vorogushin, Yu.N. Gavrish, V.M. Nikolaev, A.V. Muratov, A.P. Klinov, A.V. Ryabtsov // Вопросы атомной науки и техники. — 2001. — № 3. — С. 16-17. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-79215
record_format dspace
spelling irk-123456789-792152015-03-31T03:01:10Z New 15 MeV electron accelerator for non-destructive testing Vorogushin, M.F. Gavrish, Yu.N. Nikolaev, V.M. Muratov, A.V. Klinov, A.P. Ryabtsov, A.V. A 15 MeV accelerator with the dose rate from 80 to 120 Gy/min at 1m from the target has been designed and manufactured in NPK LUTS, the D.V.Efremov Institute, NIIEFA. The accelerator is intended for nondestructive testing (radiography, introscopy, tomography) of large scale products. Under tests an X-ray beam with the boundary energy of 15-16 MeV and dose rate of 100 Gy/min has been produced. When operating with longer pulse lengths of the accelerated electron current, the beam power was up to 140 Gy/min; with lower currents the 18 MeV energy was attained at a dose rate of 40-50 Gy/min. Biperiodic accelerating structure with axial coupling cells is applied in the accelerator. The accelerating structure buncher provides RF-focusing of the electron beam, therefore there is no need for focusing the solenoid. The focus spot diameter is no more than 2mm. To provide the electron beam stability, the accelerator is equipped with a system for automatic frequency tuning (AFT). The AFT system ensures both coarse tuning of the driver frequency against the temperature of the accelerating structure and fine tuning - against the minimum reflected power. The anode voltage of the klystron amplifier is stabilized by using a de-Q-ing system. A charging choke and pulse forming network (PFN) are located inside the irradiator unit to increase the distance between the modulator and irradiator up to 100m and to reduce losses when high-voltage high-current pulses are transmitted. The low-voltage klystron (anode voltage up to 55 kV) applied in the accelerator allows reducing the machine weight and dimensions (1100 kg and 2040x880x920mm). The accelerator is equipped with a PC-based automatic control system. In the accelerator intended for the radiographic inspection there is an external collimator with movable diaphragm jaws for testing small fragments of an inspected product. 2001 Article New 15 MeV electron accelerator for non-destructive testing / M.F. Vorogushin, Yu.N. Gavrish, V.M. Nikolaev, A.V. Muratov, A.P. Klinov, A.V. Ryabtsov // Вопросы атомной науки и техники. — 2001. — № 3. — С. 16-17. — англ. 1562-6016 PACS numbers: 29.17.+w http://dspace.nbuv.gov.ua/handle/123456789/79215 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
description A 15 MeV accelerator with the dose rate from 80 to 120 Gy/min at 1m from the target has been designed and manufactured in NPK LUTS, the D.V.Efremov Institute, NIIEFA. The accelerator is intended for nondestructive testing (radiography, introscopy, tomography) of large scale products. Under tests an X-ray beam with the boundary energy of 15-16 MeV and dose rate of 100 Gy/min has been produced. When operating with longer pulse lengths of the accelerated electron current, the beam power was up to 140 Gy/min; with lower currents the 18 MeV energy was attained at a dose rate of 40-50 Gy/min. Biperiodic accelerating structure with axial coupling cells is applied in the accelerator. The accelerating structure buncher provides RF-focusing of the electron beam, therefore there is no need for focusing the solenoid. The focus spot diameter is no more than 2mm. To provide the electron beam stability, the accelerator is equipped with a system for automatic frequency tuning (AFT). The AFT system ensures both coarse tuning of the driver frequency against the temperature of the accelerating structure and fine tuning - against the minimum reflected power. The anode voltage of the klystron amplifier is stabilized by using a de-Q-ing system. A charging choke and pulse forming network (PFN) are located inside the irradiator unit to increase the distance between the modulator and irradiator up to 100m and to reduce losses when high-voltage high-current pulses are transmitted. The low-voltage klystron (anode voltage up to 55 kV) applied in the accelerator allows reducing the machine weight and dimensions (1100 kg and 2040x880x920mm). The accelerator is equipped with a PC-based automatic control system. In the accelerator intended for the radiographic inspection there is an external collimator with movable diaphragm jaws for testing small fragments of an inspected product.
format Article
author Vorogushin, M.F.
Gavrish, Yu.N.
Nikolaev, V.M.
Muratov, A.V.
Klinov, A.P.
Ryabtsov, A.V.
spellingShingle Vorogushin, M.F.
Gavrish, Yu.N.
Nikolaev, V.M.
Muratov, A.V.
Klinov, A.P.
Ryabtsov, A.V.
New 15 MeV electron accelerator for non-destructive testing
Вопросы атомной науки и техники
author_facet Vorogushin, M.F.
Gavrish, Yu.N.
Nikolaev, V.M.
Muratov, A.V.
Klinov, A.P.
Ryabtsov, A.V.
author_sort Vorogushin, M.F.
title New 15 MeV electron accelerator for non-destructive testing
title_short New 15 MeV electron accelerator for non-destructive testing
title_full New 15 MeV electron accelerator for non-destructive testing
title_fullStr New 15 MeV electron accelerator for non-destructive testing
title_full_unstemmed New 15 MeV electron accelerator for non-destructive testing
title_sort new 15 mev electron accelerator for non-destructive testing
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2001
url http://dspace.nbuv.gov.ua/handle/123456789/79215
citation_txt New 15 MeV electron accelerator for non-destructive testing / M.F. Vorogushin, Yu.N. Gavrish, V.M. Nikolaev, A.V. Muratov, A.P. Klinov, A.V. Ryabtsov // Вопросы атомной науки и техники. — 2001. — № 3. — С. 16-17. — англ.
series Вопросы атомной науки и техники
work_keys_str_mv AT vorogushinmf new15mevelectronacceleratorfornondestructivetesting
AT gavrishyun new15mevelectronacceleratorfornondestructivetesting
AT nikolaevvm new15mevelectronacceleratorfornondestructivetesting
AT muratovav new15mevelectronacceleratorfornondestructivetesting
AT klinovap new15mevelectronacceleratorfornondestructivetesting
AT ryabtsovav new15mevelectronacceleratorfornondestructivetesting
first_indexed 2023-10-18T19:18:11Z
last_indexed 2023-10-18T19:18:11Z
_version_ 1796146548539654144