The VEPP-5 injection complex modulator revision and operational experience
For the VEPP-5 injection complex klystrons (5045, SLAC Lab., USA) power supply the four modulators producing a pulse voltage of 23.5 kV, a current of 6.3 kA, a pulse-top-duration of 3.7 µs are used. The modulator scheme designed over ten years ago has proved its reliability and let us to find out a...
Збережено в:
Дата: | 2004 |
---|---|
Автори: | , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2004
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/79357 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | The VEPP-5 injection complex modulator revision and operational experience / A.V. Akimov, P.A. Bak, E.A. Gusev, I.V. Kazarezov, N.H. Kot, A.G. Chupyra, S.P. Petrov, V.D. Yudin // Вопросы атомной науки и техники. — 2004. — № 2. — С. 99-101. — Бібліогр.: 4 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of UkraineРезюме: | For the VEPP-5 injection complex klystrons (5045, SLAC Lab., USA) power supply the four modulators producing a pulse voltage of 23.5 kV, a current of 6.3 kA, a pulse-top-duration of 3.7 µs are used. The modulator
scheme designed over ten years ago has proved its reliability and let us to find out and study the weak spots of the
modulators. The output voltage stability and pulse-to-pulse time jitter improvements are made. The results of the
thyratrons TGI1-2500/50 and TGI1-5000/50A long-term exploitation in the VEPP-5 injection complex modulators
are presented. The test results of the thyratron TGI1-2500/50 operating in the mode of more then twice pulse current
overload at the nominal mode of modulator operation are also presented. |
---|