Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the electron and X-ray radiation dose rate are developed. The conditions of c...
Збережено в:
Дата: | 2014 |
---|---|
Автори: | , , , , , , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2014
|
Назва видання: | Вопросы атомной науки и техники |
Теми: | |
Онлайн доступ: | http://dspace.nbuv.gov.ua/handle/123456789/80276 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
Цитувати: | Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko, I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ. |
Репозитарії
Digital Library of Periodicals of National Academy of Sciences of Ukraineid |
irk-123456789-80276 |
---|---|
record_format |
dspace |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
topic |
Применение ускорителей в радиационных технологиях Применение ускорителей в радиационных технологиях |
spellingShingle |
Применение ускорителей в радиационных технологиях Применение ускорителей в радиационных технологиях Kutny, V.E. Nikiforov, V.I. Opalev, O.A. Rogov, Yu.V. Rybka, A.V. Shevchenko, V.A. Shlyakhov, I.N. Strelnitsky, V.E. Tenishev, A.Eh. Uvarov, V.L. Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields Вопросы атомной науки и техники |
description |
Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond
film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the
electron and X-ray radiation dose rate are developed. The conditions of calibration were studied by means of computer
simulation. For determination of detector sensitivity to electron radiation, it was placed inside of a standard
polystyrene phantom. An additional filter of electrons was used at measurement in the X-ray field. Every time detector
irradiation was carried out together with the Harwell Red Perpex 4034 dosimeters, which registrations provided
the calibration data. The measurements, executed at the LU-10, EPOS and LU-40 linacs of NSC KIPT, have demonstrated,
that the values of detector sensitivity against each type of radiation are close and conform to ones obtained
earlier for the low-intensity radiation fields. Considering significant radiation durability of the CVD-diamond, it
enables its application in technological dosimetry. |
format |
Article |
author |
Kutny, V.E. Nikiforov, V.I. Opalev, O.A. Rogov, Yu.V. Rybka, A.V. Shevchenko, V.A. Shlyakhov, I.N. Strelnitsky, V.E. Tenishev, A.Eh. Uvarov, V.L. |
author_facet |
Kutny, V.E. Nikiforov, V.I. Opalev, O.A. Rogov, Yu.V. Rybka, A.V. Shevchenko, V.A. Shlyakhov, I.N. Strelnitsky, V.E. Tenishev, A.Eh. Uvarov, V.L. |
author_sort |
Kutny, V.E. |
title |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields |
title_short |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields |
title_full |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields |
title_fullStr |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields |
title_full_unstemmed |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields |
title_sort |
calibration of cvd-diamond based dosimeter in high-power electron and x-ray radiation fields |
publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
publishDate |
2014 |
topic_facet |
Применение ускорителей в радиационных технологиях |
url |
http://dspace.nbuv.gov.ua/handle/123456789/80276 |
citation_txt |
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko,
I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ. |
series |
Вопросы атомной науки и техники |
work_keys_str_mv |
AT kutnyve calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT nikiforovvi calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT opalevoa calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT rogovyuv calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT rybkaav calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT shevchenkova calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT shlyakhovin calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT strelnitskyve calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT tenishevaeh calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields AT uvarovvl calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields |
first_indexed |
2023-10-18T19:20:36Z |
last_indexed |
2023-10-18T19:20:36Z |
_version_ |
1796146658319269888 |
spelling |
irk-123456789-802762015-04-15T03:02:29Z Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields Kutny, V.E. Nikiforov, V.I. Opalev, O.A. Rogov, Yu.V. Rybka, A.V. Shevchenko, V.A. Shlyakhov, I.N. Strelnitsky, V.E. Tenishev, A.Eh. Uvarov, V.L. Применение ускорителей в радиационных технологиях Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the electron and X-ray radiation dose rate are developed. The conditions of calibration were studied by means of computer simulation. For determination of detector sensitivity to electron radiation, it was placed inside of a standard polystyrene phantom. An additional filter of electrons was used at measurement in the X-ray field. Every time detector irradiation was carried out together with the Harwell Red Perpex 4034 dosimeters, which registrations provided the calibration data. The measurements, executed at the LU-10, EPOS and LU-40 linacs of NSC KIPT, have demonstrated, that the values of detector sensitivity against each type of radiation are close and conform to ones obtained earlier for the low-intensity radiation fields. Considering significant radiation durability of the CVD-diamond, it enables its application in technological dosimetry. Описаны результаты исследования дозиметрических характеристик изготовленного в ННЦ ХФТИ опытного образца детектора на основе поликристаллической алмазной пленки (CVD-алмаз). Разработаны методики калибровки детекторов по мощности поглощенной дозы электронного и тормозного излучений. Условия калибровки исследованы методом компьютерного моделирования. Для определения чувствительности детектора к электронному излучению его помещали внутри фантома из полистирола. При измерениях в поле тормозного излучения использовался дополнительный фильтр электронов. В каждом случае облучение детектора выполнялось совместно с дозиметрами Harwell Red Perspex 4034, по показаниям которых производилась калибровка. Проведенные на ускорителях ЛУ-10, ЭПОС и ЛУ-40 ННЦ ХФТИ измерения показали, что значения чувствительности детектора для каждого вида излучения близки и согласуются с полученными ранее в условиях полей излучения низкой интенсивности. Учитывая высокую радиационную стойкость CVD-алмаза, это обеспечивает возможность его применения в технологической дозиметрии. Описанo результати дослідження дозиметричних характеристик виготовленого в ННЦ ХФТІ дослідного зразка детектора на основі полікристалічної алмазної плівки (CVD-алмаз). Розроблено методики калібрування детекторів за потужністю поглинутої дози електронного та гальмівного випромінювань. Методом комп'ютерного моделювання досліджені умови калібрувань. Для визначення чутливості детектора до електронного випромінювання його розміщували усередині стандартного фантома з полістиролу. При вимірюваннях у полі гальмівного випромінювання використовувався додатковий фільтр електронів. У кожному випадку опромінювання детектора виконувалося спільно з дозиметрами Harwell Red Perpex 4034, за показаннями яких проводилося калібрування. Проведені на прискорювачах ЛУ-10, ЕПОС та ЛУ-40 ННЦ ХФТІ вимірювання показали, що значення чутливості детектора для кожного виду випромінювання є близькі і узгоджуються з такими, що одержані раніше в умовах полів випромінювання низької інтенсивності. Зважаючи на значну радіаційну стійкість CVD-алмазу, це забезпечує можливість його застосування в технологічній дозиметрії. 2014 Article Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko, I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ. 1562-6016 PACS: 07.57.Kp, 29.40.-n, 85.25.Pb, 81.05.ug http://dspace.nbuv.gov.ua/handle/123456789/80276 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України |