Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields

Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the electron and X-ray radiation dose rate are developed. The conditions of c...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2014
Автори: Kutny, V.E., Nikiforov, V.I., Opalev, O.A., Rogov, Yu.V., Rybka, A.V., Shevchenko, V.A., Shlyakhov, I.N., Strelnitsky, V.E., Tenishev, A.Eh., Uvarov, V.L.
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2014
Назва видання:Вопросы атомной науки и техники
Теми:
Онлайн доступ:http://dspace.nbuv.gov.ua/handle/123456789/80276
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko, I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id irk-123456789-80276
record_format dspace
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Применение ускорителей в радиационных технологиях
Применение ускорителей в радиационных технологиях
spellingShingle Применение ускорителей в радиационных технологиях
Применение ускорителей в радиационных технологиях
Kutny, V.E.
Nikiforov, V.I.
Opalev, O.A.
Rogov, Yu.V.
Rybka, A.V.
Shevchenko, V.A.
Shlyakhov, I.N.
Strelnitsky, V.E.
Tenishev, A.Eh.
Uvarov, V.L.
Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
Вопросы атомной науки и техники
description Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the electron and X-ray radiation dose rate are developed. The conditions of calibration were studied by means of computer simulation. For determination of detector sensitivity to electron radiation, it was placed inside of a standard polystyrene phantom. An additional filter of electrons was used at measurement in the X-ray field. Every time detector irradiation was carried out together with the Harwell Red Perpex 4034 dosimeters, which registrations provided the calibration data. The measurements, executed at the LU-10, EPOS and LU-40 linacs of NSC KIPT, have demonstrated, that the values of detector sensitivity against each type of radiation are close and conform to ones obtained earlier for the low-intensity radiation fields. Considering significant radiation durability of the CVD-diamond, it enables its application in technological dosimetry.
format Article
author Kutny, V.E.
Nikiforov, V.I.
Opalev, O.A.
Rogov, Yu.V.
Rybka, A.V.
Shevchenko, V.A.
Shlyakhov, I.N.
Strelnitsky, V.E.
Tenishev, A.Eh.
Uvarov, V.L.
author_facet Kutny, V.E.
Nikiforov, V.I.
Opalev, O.A.
Rogov, Yu.V.
Rybka, A.V.
Shevchenko, V.A.
Shlyakhov, I.N.
Strelnitsky, V.E.
Tenishev, A.Eh.
Uvarov, V.L.
author_sort Kutny, V.E.
title Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
title_short Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
title_full Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
title_fullStr Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
title_full_unstemmed Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields
title_sort calibration of cvd-diamond based dosimeter in high-power electron and x-ray radiation fields
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2014
topic_facet Применение ускорителей в радиационных технологиях
url http://dspace.nbuv.gov.ua/handle/123456789/80276
citation_txt Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko, I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ.
series Вопросы атомной науки и техники
work_keys_str_mv AT kutnyve calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT nikiforovvi calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT opalevoa calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT rogovyuv calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT rybkaav calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT shevchenkova calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT shlyakhovin calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT strelnitskyve calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT tenishevaeh calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
AT uvarovvl calibrationofcvddiamondbaseddosimeterinhighpowerelectronandxrayradiationfields
first_indexed 2023-10-18T19:20:36Z
last_indexed 2023-10-18T19:20:36Z
_version_ 1796146658319269888
spelling irk-123456789-802762015-04-15T03:02:29Z Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields Kutny, V.E. Nikiforov, V.I. Opalev, O.A. Rogov, Yu.V. Rybka, A.V. Shevchenko, V.A. Shlyakhov, I.N. Strelnitsky, V.E. Tenishev, A.Eh. Uvarov, V.L. Применение ускорителей в радиационных технологиях Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against the electron and X-ray radiation dose rate are developed. The conditions of calibration were studied by means of computer simulation. For determination of detector sensitivity to electron radiation, it was placed inside of a standard polystyrene phantom. An additional filter of electrons was used at measurement in the X-ray field. Every time detector irradiation was carried out together with the Harwell Red Perpex 4034 dosimeters, which registrations provided the calibration data. The measurements, executed at the LU-10, EPOS and LU-40 linacs of NSC KIPT, have demonstrated, that the values of detector sensitivity against each type of radiation are close and conform to ones obtained earlier for the low-intensity radiation fields. Considering significant radiation durability of the CVD-diamond, it enables its application in technological dosimetry. Описаны результаты исследования дозиметрических характеристик изготовленного в ННЦ ХФТИ опытного образца детектора на основе поликристаллической алмазной пленки (CVD-алмаз). Разработаны методики калибровки детекторов по мощности поглощенной дозы электронного и тормозного излучений. Условия калибровки исследованы методом компьютерного моделирования. Для определения чувствительности детектора к электронному излучению его помещали внутри фантома из полистирола. При измерениях в поле тормозного излучения использовался дополнительный фильтр электронов. В каждом случае облучение детектора выполнялось совместно с дозиметрами Harwell Red Perspex 4034, по показаниям которых производилась калибровка. Проведенные на ускорителях ЛУ-10, ЭПОС и ЛУ-40 ННЦ ХФТИ измерения показали, что значения чувствительности детектора для каждого вида излучения близки и согласуются с полученными ранее в условиях полей излучения низкой интенсивности. Учитывая высокую радиационную стойкость CVD-алмаза, это обеспечивает возможность его применения в технологической дозиметрии. Описанo результати дослідження дозиметричних характеристик виготовленого в ННЦ ХФТІ дослідного зразка детектора на основі полікристалічної алмазної плівки (CVD-алмаз). Розроблено методики калібрування детекторів за потужністю поглинутої дози електронного та гальмівного випромінювань. Методом комп'ютерного моделювання досліджені умови калібрувань. Для визначення чутливості детектора до електронного випромінювання його розміщували усередині стандартного фантома з полістиролу. При вимірюваннях у полі гальмівного випромінювання використовувався додатковий фільтр електронів. У кожному випадку опромінювання детектора виконувалося спільно з дозиметрами Harwell Red Perpex 4034, за показаннями яких проводилося калібрування. Проведені на прискорювачах ЛУ-10, ЕПОС та ЛУ-40 ННЦ ХФТІ вимірювання показали, що значення чутливості детектора для кожного виду випромінювання є близькі і узгоджуються з такими, що одержані раніше в умовах полів випромінювання низької інтенсивності. Зважаючи на значну радіаційну стійкість CVD-алмазу, це забезпечує можливість його застосування в технологічній дозиметрії. 2014 Article Calibration of CVD-diamond based dosimeter in high-power electron and X-ray radiation fields / V.E. Kutny, V.I. Nikiforov, O.A. Opalev, Yu.V. Rogov, A.V. Rybka, V.A. Shevchenko, I.N. Shlyakhov, V.E. Strelnitsky, A.Eh. Tenishev, V.L. Uvarov // Вопросы атомной науки и техники. — 2014. — № 3. — С. 162-165. — Бібліогр.: 12 назв. — англ. 1562-6016 PACS: 07.57.Kp, 29.40.-n, 85.25.Pb, 81.05.ug http://dspace.nbuv.gov.ua/handle/123456789/80276 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України