Beam position monitoring in pulsed high-current electron linear accelerators
The paper presents design and test results for the channel measuring the position (relative to the accelerator axis) of the center of the electron beam with a pulse length of 4 ms, a pulse current up to 1000 mA, a pulse frequency of 150(300) Hz and energy up to 30 MeV. The measurement error was 0.5...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2000
|
Series: | Вопросы атомной науки и техники |
Subjects: | |
Online Access: | http://dspace.nbuv.gov.ua/handle/123456789/82263 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
irk-123456789-82263 |
---|---|
record_format |
dspace |
spelling |
irk-123456789-822632015-05-31T22:41:03Z Beam position monitoring in pulsed high-current electron linear accelerators Boriskin, V.N. Gurin, V.A. Dovbnya, A.N. Reprintsev, L.V. Savchenko, A.N. Tatanov, V.I. Shendrik, V.A. Тheory and technics of particle acceleration The paper presents design and test results for the channel measuring the position (relative to the accelerator axis) of the center of the electron beam with a pulse length of 4 ms, a pulse current up to 1000 mA, a pulse frequency of 150(300) Hz and energy up to 30 MeV. The measurement error was 0.5 mm for a 42 mm aperture. A magneto-inductive- type four-winding monitor was used. The signals from the monitor could be computer-processed in two ways: either by the signal peak or by the integral value of the signal. The procedure of averaging the results was provided. Two measuring channels ensuring safe beam guiding were created in the two-section electron linac “EPOS”. A three-year operation with the beam has demonstrated their reliability and convenience in service. 2000 Article Beam position monitoring in pulsed high-current electron linear accelerators / V.N. Boriskin, V.A. Gurin, A.N. Dovbnya, L.V. Reprintsev, A.N. Savchenko, V.I. Tatanov, V.A. Shendrik // Вопросы атомной науки и техники. — 2000. — № 2. — С. 91-93. — Бібліогр.: 15 назв. — англ. 1562-6016 PACS: 29.17.+w, 29.27.eg http://dspace.nbuv.gov.ua/handle/123456789/82263 en Вопросы атомной науки и техники Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
collection |
DSpace DC |
language |
English |
topic |
Тheory and technics of particle acceleration Тheory and technics of particle acceleration |
spellingShingle |
Тheory and technics of particle acceleration Тheory and technics of particle acceleration Boriskin, V.N. Gurin, V.A. Dovbnya, A.N. Reprintsev, L.V. Savchenko, A.N. Tatanov, V.I. Shendrik, V.A. Beam position monitoring in pulsed high-current electron linear accelerators Вопросы атомной науки и техники |
description |
The paper presents design and test results for the channel measuring the position (relative to the accelerator axis) of the center of the electron beam with a pulse length of 4 ms, a pulse current up to 1000 mA, a pulse frequency of 150(300) Hz and energy up to 30 MeV. The measurement error was 0.5 mm for a 42 mm aperture. A magneto-inductive- type four-winding monitor was used. The signals from the monitor could be computer-processed in two ways: either by the signal peak or by the integral value of the signal. The procedure of averaging the results was provided. Two measuring channels ensuring safe beam guiding were created in the two-section electron linac “EPOS”. A three-year operation with the beam has demonstrated their reliability and convenience in service. |
format |
Article |
author |
Boriskin, V.N. Gurin, V.A. Dovbnya, A.N. Reprintsev, L.V. Savchenko, A.N. Tatanov, V.I. Shendrik, V.A. |
author_facet |
Boriskin, V.N. Gurin, V.A. Dovbnya, A.N. Reprintsev, L.V. Savchenko, A.N. Tatanov, V.I. Shendrik, V.A. |
author_sort |
Boriskin, V.N. |
title |
Beam position monitoring in pulsed high-current electron linear accelerators |
title_short |
Beam position monitoring in pulsed high-current electron linear accelerators |
title_full |
Beam position monitoring in pulsed high-current electron linear accelerators |
title_fullStr |
Beam position monitoring in pulsed high-current electron linear accelerators |
title_full_unstemmed |
Beam position monitoring in pulsed high-current electron linear accelerators |
title_sort |
beam position monitoring in pulsed high-current electron linear accelerators |
publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
publishDate |
2000 |
topic_facet |
Тheory and technics of particle acceleration |
url |
http://dspace.nbuv.gov.ua/handle/123456789/82263 |
citation_txt |
Beam position monitoring in pulsed high-current electron linear accelerators / V.N. Boriskin, V.A. Gurin, A.N. Dovbnya, L.V. Reprintsev, A.N. Savchenko, V.I. Tatanov, V.A. Shendrik // Вопросы атомной науки и техники. — 2000. — № 2. — С. 91-93. — Бібліогр.: 15 назв. — англ. |
series |
Вопросы атомной науки и техники |
work_keys_str_mv |
AT boriskinvn beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT gurinva beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT dovbnyaan beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT reprintsevlv beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT savchenkoan beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT tatanovvi beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators AT shendrikva beampositionmonitoringinpulsedhighcurrentelectronlinearaccelerators |
first_indexed |
2024-03-30T08:18:10Z |
last_indexed |
2024-03-30T08:18:10Z |
_version_ |
1796146861272203264 |