2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: Query fl=%2A&wt=json&json.nl=arrarr&q=id%3A%22journalsuranua-geofizicheskiy-article-117578%22&qt=morelikethis&rows=5
2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: => GET http://localhost:8983/solr/biblio/select?fl=%2A&wt=json&json.nl=arrarr&q=id%3A%22journalsuranua-geofizicheskiy-article-117578%22&qt=morelikethis&rows=5
2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: <= 200 OK
2025-02-23T10:56:03-05:00 DEBUG: Deserialized SOLR response
Mathematical model of the electric field of the cathode protection system of the main pipeline
In calculations of cathode protection parameters for the main pipelines the value of transitional resistance of anti-corrosion coating is used. Specific resistance of the loading without defects is valuated by numbers from hundreds of kiloOhm/m2 to tenths of megOhm/m2, while the value of transitiona...
Saved in:
Main Author: | Lukovich, V. V. |
---|---|
Format: | Article |
Language: | rus |
Published: |
Subbotin Institute of Geophysics of the NAS of Ukraine
2010
|
Online Access: | https://journals.uran.ua/geofizicheskiy/article/view/117578 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: Query fl=%2A&rows=40&rows=5&wt=json&json.nl=arrarr&q=id%3A%22journalsuranua-geofizicheskiy-article-117578%22&qt=morelikethis
2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: => GET http://localhost:8983/solr/biblio/select?fl=%2A&rows=40&rows=5&wt=json&json.nl=arrarr&q=id%3A%22journalsuranua-geofizicheskiy-article-117578%22&qt=morelikethis
2025-02-23T10:56:03-05:00 DEBUG: VuFindSearch\Backend\Solr\Connector: <= 200 OK
2025-02-23T10:56:03-05:00 DEBUG: Deserialized SOLR response
Similar Items
-
Mathematic model of electric field for the system of cathode protection of main pipeline
by: V. V. Lukovych, et al.
Published: (2010) -
Mathematical model of electric field in the zone of insulation peeling off the pipe surface under cathodic polarization
by: Lukovich, V. V., et al.
Published: (2013) -
O polarization potential of the main pipeline
by: Lukovich, V. V., et al.
Published: (2010) -
The electric field in the vicinity of the damage to the pipeline's anticorrosive cover
by: Lukovich, V. V.
Published: (2011) -
Calculation of the damage area in anticorrosion coating of the pipeline section according to the data of electric measurements
by: Lukovich, V. V., et al.
Published: (2012)