Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield
The interpretation of the 3D model of the Kocheriv structure of the Ukrainian shield, based on the data of experimental observations of the low-frequency electromagnetic field of the Earth in a wide range of periods, was carried out by S.I. Subbotin Institute of Geophysics of the National Academy of...
Збережено в:
| Дата: | 2024 |
|---|---|
| Автори: | , , |
| Формат: | Стаття |
| Мова: | Українська |
| Опубліковано: |
S. Subbotin Institute of Geophysics of the NAS of Ukraine
2024
|
| Теми: | |
| Онлайн доступ: | https://journals.uran.ua/geofizicheskiy/article/view/304895 |
| Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
| Назва журналу: | Geofizicheskiy Zhurnal |
Репозитарії
Geofizicheskiy Zhurnal| _version_ | 1856543605120827392 |
|---|---|
| author | Ilienko, Volodymyr Burakhovych, Tatiana Kushnir, Anton |
| author_facet | Ilienko, Volodymyr Burakhovych, Tatiana Kushnir, Anton |
| author_sort | Ilienko, Volodymyr |
| baseUrl_str | |
| collection | OJS |
| datestamp_date | 2024-09-02T12:40:28Z |
| description | The interpretation of the 3D model of the Kocheriv structure of the Ukrainian shield, based on the data of experimental observations of the low-frequency electromagnetic field of the Earth in a wide range of periods, was carried out by S.I. Subbotin Institute of Geophysics of the National Academy of Sciences of Ukraine. The main result of the geological-geoelectrical interpretation is that the Kocherivsynclinorium within its geological limits did not appear as a solid conductive structure; new anomalies of low resistance were discovered in the near-surface part of the crust (from the surface to 0.5—2 km), which correspond to structural and metallogenic features,extend along the Vilensky and Kocheriv faults, which belong to the Zvizdal-Zaliska fault zone and the Vilshansky (Brusyliv fault zone) and their intersection with the Central fault zone; an abnormally heterogeneous distribution of resistivity in the crust at depths from 15 to 30 km west of the Ukrainian shield was confirmed. The resistivity of the host rocks is on average 10,000 Ω·m, it extends over almost the entire thickness of the crust up to 50 km, which spatially agrees well with the massifs of granites of the Zhytomyr and Fastiv complexes of the Volyn and Ros’ Domain. The nature of the electrical conductivity anomaly may be the result of transport of ore components together with fluids from the crust and mantle during tectonic-magmatic activation, which allows predicting areas promising for endogenous mineralization as projections of deep anomalies to the day surface.
A connection between endogenous mineralization within the Kocheriv structure and low- resistivity anomalies was established. Zones of deep faults, to which low-resistivity anomalies are confined, require further study, such as the sublatitude anomaly along the Masheryn fault. Anomalies in the north of the Kocheriv structure at the intersection of the Kocheriv and Glukhiv faults and further south within the deepest (up to 2 km from the surface) near-surface sub-latitudinal conductor, which spatially coincides with the Komariv sub-latitudinal fault zone, stand out as promising for mineral exploration that meets geoelectrical criteria. |
| first_indexed | 2025-07-17T11:14:17Z |
| format | Article |
| id | journalsuranua-geofizicheskiy-article-304895 |
| institution | Geofizicheskiy Zhurnal |
| language | Ukrainian |
| last_indexed | 2025-07-17T11:14:17Z |
| publishDate | 2024 |
| publisher | S. Subbotin Institute of Geophysics of the NAS of Ukraine |
| record_format | ojs |
| spelling | journalsuranua-geofizicheskiy-article-3048952024-09-02T12:40:28Z Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield Інтерпретація 3D геоелектричної моделі Кочерівської структури заходу Українського щита Ilienko, Volodymyr Burakhovych, Tatiana Kushnir, Anton geoelectromagnetic methods interpretation of a three-dimensional model electrical conductivity anomalies ore occurrences of minerals Ukrainian shield Kocheriv structure fault zone геоелектромагнітні методи інтерпретація тривимірної моделі аномалії електропровідності рудопрояви корисних копалин Український щит Кочерівська структура зона розломів The interpretation of the 3D model of the Kocheriv structure of the Ukrainian shield, based on the data of experimental observations of the low-frequency electromagnetic field of the Earth in a wide range of periods, was carried out by S.I. Subbotin Institute of Geophysics of the National Academy of Sciences of Ukraine. The main result of the geological-geoelectrical interpretation is that the Kocherivsynclinorium within its geological limits did not appear as a solid conductive structure; new anomalies of low resistance were discovered in the near-surface part of the crust (from the surface to 0.5—2 km), which correspond to structural and metallogenic features,extend along the Vilensky and Kocheriv faults, which belong to the Zvizdal-Zaliska fault zone and the Vilshansky (Brusyliv fault zone) and their intersection with the Central fault zone; an abnormally heterogeneous distribution of resistivity in the crust at depths from 15 to 30 km west of the Ukrainian shield was confirmed. The resistivity of the host rocks is on average 10,000 Ω·m, it extends over almost the entire thickness of the crust up to 50 km, which spatially agrees well with the massifs of granites of the Zhytomyr and Fastiv complexes of the Volyn and Ros’ Domain. The nature of the electrical conductivity anomaly may be the result of transport of ore components together with fluids from the crust and mantle during tectonic-magmatic activation, which allows predicting areas promising for endogenous mineralization as projections of deep anomalies to the day surface. A connection between endogenous mineralization within the Kocheriv structure and low- resistivity anomalies was established. Zones of deep faults, to which low-resistivity anomalies are confined, require further study, such as the sublatitude anomaly along the Masheryn fault. Anomalies in the north of the Kocheriv structure at the intersection of the Kocheriv and Glukhiv faults and further south within the deepest (up to 2 km from the surface) near-surface sub-latitudinal conductor, which spatially coincides with the Komariv sub-latitudinal fault zone, stand out as promising for mineral exploration that meets geoelectrical criteria. Зроблено інтерпретацію 3D моделі Кочерівської структури заходу Українського щита, що побудована за даними експериментальних спостережень низькочастотного електромагнітного поля Землі в широкому діапазоні періодів, які було проведено Інститутом геофізики ім. С.І.Суботіна Національної академії наук України. Основним результатом геолого-геоелектричної інтерпретації є те, що Кочерівський синклінорій у його геологічних межах не проявився як суцільна електропровідна структура; виявлено нові аномалії низького опору у приповерхневій частині земної кори (від поверхні до 0.5-2 км), які відповідають структурним й металогенічним особливостям, та простягаються вздовж розломів та їх перетинів, таких як, Віленський, Кочерівський, Центральний та Вільшанський; підтверджено аномально неоднорідний розподіл питомого опору у земній корі на глибинах від 15 до 30 км заходу Українського щита. Опір вміщуючих порід становить в середньому 10000 Ом·м, розповсюджується майже на всю потужність земної кори до 50 км, що просторово добре узгоджуються з масивами гранітів житомирського та фастівського комплексів Волинського та Росинського мегаблоків. Природа аномалії електропровідності може бути результатом транспортування рудних компонентів разом з флюїдами із кори та мантії під час тектоно-магматичної активізації, що дозволяє прогнозувати ділянки, перспективні на ендогенне зруденіння як проекції глибинних аномалій на денну поверхню. Встановлено зв'язок між ендогенними зруденіннями, що знаходяться у межах Кочерівської структури, і низькоомними аномаліями. Зони глибинних розломів, до яких приурочені низькоомні аномалії, потребують подальшого вивчення, наприклад, субширотна аномалія вздовж Машеринського розлому. Як перспективну для пошуку корисних копалин, яка відповідає геоелектричним критеріям, виділяються аномалії на півночі Кочерівської структури в вузлі перетину Кочерівського та Глухівського розломів та південніше в межах найглибшого (від поверхні до 2 км) приповерхневого субширотного провідника, який просторово співпадає з Комарівською субширотною зоною розломів. S. Subbotin Institute of Geophysics of the NAS of Ukraine 2024-09-02 Article Article application/pdf https://journals.uran.ua/geofizicheskiy/article/view/304895 10.24028/gj.v46i4.304895 Geofizicheskiy Zhurnal; Vol. 46 No. 4 (2024) Геофизический журнал; Том 46 № 4 (2024) Геофізичний журнал; Том 46 № 4 (2024) 2524-1052 0203-3100 uk https://journals.uran.ua/geofizicheskiy/article/view/304895/302158 Copyright (c) 2024 Tatiana Burakhovych, Volodymyr, Anton https://creativecommons.org/licenses/by-nc-sa/4.0 |
| spellingShingle | geoelectromagnetic methods interpretation of a three-dimensional model electrical conductivity anomalies ore occurrences of minerals Ukrainian shield Kocheriv structure fault zone Ilienko, Volodymyr Burakhovych, Tatiana Kushnir, Anton Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title | Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title_alt | Інтерпретація 3D геоелектричної моделі Кочерівської структури заходу Українського щита |
| title_full | Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title_fullStr | Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title_full_unstemmed | Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title_short | Interpretation of the 3D geoelectrical model of the Kocheriv structure of the Western Ukrainian Shield |
| title_sort | interpretation of the 3d geoelectrical model of the kocheriv structure of the western ukrainian shield |
| topic | geoelectromagnetic methods interpretation of a three-dimensional model electrical conductivity anomalies ore occurrences of minerals Ukrainian shield Kocheriv structure fault zone |
| topic_facet | geoelectromagnetic methods interpretation of a three-dimensional model electrical conductivity anomalies ore occurrences of minerals Ukrainian shield Kocheriv structure fault zone геоелектромагнітні методи інтерпретація тривимірної моделі аномалії електропровідності рудопрояви корисних копалин Український щит Кочерівська структура зона розломів |
| url | https://journals.uran.ua/geofizicheskiy/article/view/304895 |
| work_keys_str_mv | AT ilienkovolodymyr interpretationofthe3dgeoelectricalmodelofthekocherivstructureofthewesternukrainianshield AT burakhovychtatiana interpretationofthe3dgeoelectricalmodelofthekocherivstructureofthewesternukrainianshield AT kushniranton interpretationofthe3dgeoelectricalmodelofthekocherivstructureofthewesternukrainianshield AT ilienkovolodymyr ínterpretacíâ3dgeoelektričnoímodelíkočerívsʹkoístrukturizahoduukraínsʹkogoŝita AT burakhovychtatiana ínterpretacíâ3dgeoelektričnoímodelíkočerívsʹkoístrukturizahoduukraínsʹkogoŝita AT kushniranton ínterpretacíâ3dgeoelektričnoímodelíkočerívsʹkoístrukturizahoduukraínsʹkogoŝita |