The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences

The generalized dependences for the analysis of energy efficiency of a supercritical R744 cycle refrigeration mechine and heat pumps are developed. The influence of regime parameters of a supercritical cycle and effects of their interaction on the coefficient of performance is examined. The expedien...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2016
Автори: Мацевитый, Ю. М., Братута, Э. Г., Харлампиди, Д. Х.
Формат: Стаття
Мова:Russian
Опубліковано: Journal of Mechanical Engineering 2016
Теми:
Онлайн доступ:https://journals.uran.ua/jme/article/view/70042
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Journal of Mechanical Engineering

Репозитарії

Journal of Mechanical Engineering
id journalsuranuajme-article-70042
record_format ojs
spelling journalsuranuajme-article-700422016-05-30T14:59:41Z The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences Обобщенные зависимости для анализа сверхкритических циклов холодильных машин и тепловых насосов Мацевитый, Ю. М. Братута, Э. Г. Харлампиди, Д. Х. УДК 621.564 621.577 УДК 621.564 621.577 УДК 621.564 621.577 The generalized dependences for the analysis of energy efficiency of a supercritical R744 cycle refrigeration mechine and heat pumps are developed. The influence of regime parameters of a supercritical cycle and effects of their interaction on the coefficient of performance is examined. The expediency of application of regeneration in the supercritical cycles, and also uses expender is estimated Получены обобщенные зависимости для анализа энергетической эффективности холодильных машин и тепловых насосов, работающих по сверхкритическому циклу с хладагентом R744. Проведен анализ взаимного влияния режимных параметров сверхкритического цикла на холодильный коэффициент. Дана оценка целесообразности применения регенерации в сверхкритических циклах и использования детандера Отримано узагальнені залежності для аналізу енергетичної ефективності холодильних машин та теплових насосів, що працюють за надкритичним циклом з холодоагентом R744. Проведено аналіз взаємного впливу режимних параметрів надкритичного циклу на холодильний коефіцієнт. Надано оцінку доцільності застосування регенерації у надкритичних циклах, а також використання детандера Journal of Mechanical Engineering Проблемы машиностроения Проблеми машинобудування 2016-05-30 Article Article application/pdf https://journals.uran.ua/jme/article/view/70042 Journal of Mechanical Engineering; Vol. 14 No. 1 (2011); 13-22 Проблемы машиностроения; Том 14 № 1 (2011); 13-22 Проблеми машинобудування; Том 14 № 1 (2011); 13-22 2709-2992 2709-2984 ru https://journals.uran.ua/jme/article/view/70042/65304 Copyright (c) 2016 Ю. М. Мацевитый, Э. Г. Братута, Д. Х. Харлампиди https://creativecommons.org/licenses/by-nd/4.0
institution Journal of Mechanical Engineering
collection OJS
language Russian
topic УДК 621.564
621.577
УДК 621.564
621.577
УДК 621.564
621.577
spellingShingle УДК 621.564
621.577
УДК 621.564
621.577
УДК 621.564
621.577
Мацевитый, Ю. М.
Братута, Э. Г.
Харлампиди, Д. Х.
The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
topic_facet УДК 621.564
621.577
УДК 621.564
621.577
УДК 621.564
621.577
format Article
author Мацевитый, Ю. М.
Братута, Э. Г.
Харлампиди, Д. Х.
author_facet Мацевитый, Ю. М.
Братута, Э. Г.
Харлампиди, Д. Х.
author_sort Мацевитый, Ю. М.
title The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_short The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_full The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_fullStr The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_full_unstemmed The analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_sort analysis of the supercritical cycles of refrigeration machines and heat pumps by means of the generalized dependences
title_alt Обобщенные зависимости для анализа сверхкритических циклов холодильных машин и тепловых насосов
description The generalized dependences for the analysis of energy efficiency of a supercritical R744 cycle refrigeration mechine and heat pumps are developed. The influence of regime parameters of a supercritical cycle and effects of their interaction on the coefficient of performance is examined. The expediency of application of regeneration in the supercritical cycles, and also uses expender is estimated
publisher Journal of Mechanical Engineering
publishDate 2016
url https://journals.uran.ua/jme/article/view/70042
work_keys_str_mv AT macevityjûm theanalysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
AT bratutaég theanalysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
AT harlampididh theanalysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
AT macevityjûm obobŝennyezavisimostidlâanalizasverhkritičeskihciklovholodilʹnyhmašiniteplovyhnasosov
AT bratutaég obobŝennyezavisimostidlâanalizasverhkritičeskihciklovholodilʹnyhmašiniteplovyhnasosov
AT harlampididh obobŝennyezavisimostidlâanalizasverhkritičeskihciklovholodilʹnyhmašiniteplovyhnasosov
AT macevityjûm analysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
AT bratutaég analysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
AT harlampididh analysisofthesupercriticalcyclesofrefrigerationmachinesandheatpumpsbymeansofthegeneralizeddependences
first_indexed 2024-06-01T14:43:18Z
last_indexed 2024-06-01T14:43:18Z
_version_ 1800670280467611648