PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)

This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units...

Повний опис

Збережено в:
Бібліографічні деталі
Видавець:Kamianets-Podilskyi National Ivan Ohiienko University
Дата:2016
Автори: Ali Zada, Parviz, Tuncay, Nejar, Ozturk, Salih Baris, Mamedov, Havar, Abdullaev, S.
Формат: Стаття
Мова:English
Опубліковано: Kamianets-Podilskyi National Ivan Ohiienko University 2016
Онлайн доступ:http://mcm-tech.kpnu.edu.ua/article/view/81958
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!

Репозиторії

Mathematical and computer modelling. Series: Technical sciences
id mcmtechkpnueduua-article-81958
record_format ojs
spelling mcmtechkpnueduua-article-819582019-03-06T10:39:37Z PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) Ali Zada, Parviz Tuncay, Nejar Ozturk, Salih Baris Mamedov, Havar Abdullaev, S. This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units of onboard complexesin ground-based air navigation when preflight ground check-service is made. The transport management at thousands of small provincial airports in the former country is still unfortunate. The same situation is in Northern and central Central Asia, Northern Caucasian and Trans-Caucasian Mountains, oriented to small civil and agricultural services airports, etc. Everywhere the phaseand line voltage amplitude unbalance can reach between 10-15% at the settlement’s power tiny transformer or generator and there are thousands and thousands of such local «airports» [1, 6]. This paperhas been editing by a native speaker, Ms. Rachel Alcorn — our sincere thanks. Kamianets-Podilskyi National Ivan Ohiienko University 2016-04-20 Article Article application/pdf http://mcm-tech.kpnu.edu.ua/article/view/81958 10.32626/2308-5916.2016-13.5-16 Mathematical and computer modelling. Series: Technical sciences; 2016: Mathematical and computer modelling. Series: Technical sciences. Issue 13; 5-16 Математичне та комп'ютерне моделювання. Серія: Технічні науки ; 2016: Математичне та комп'ютерне моделювання. Серія: Технічні науки. Випуск 13; 5-16 2308-5916 10.32626/2308-5916.2016-13 en http://mcm-tech.kpnu.edu.ua/article/view/81958/77612 Авторське право (c) 2021 Математичне та комп'ютерне моделювання. Серія: Технічні науки
institution Mathematical and computer modelling. Series: Technical sciences
collection OJS
language English
format Article
author Ali Zada, Parviz
Tuncay, Nejar
Ozturk, Salih Baris
Mamedov, Havar
Abdullaev, S.
spellingShingle Ali Zada, Parviz
Tuncay, Nejar
Ozturk, Salih Baris
Mamedov, Havar
Abdullaev, S.
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
author_facet Ali Zada, Parviz
Tuncay, Nejar
Ozturk, Salih Baris
Mamedov, Havar
Abdullaev, S.
author_sort Ali Zada, Parviz
title PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
title_short PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
title_full PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
title_fullStr PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
title_full_unstemmed PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
title_sort parametrical method of low-frequency harmonics suppression in rectifier’s output voltage under supply voltage unbalances (mathematical model, study and industrial application)
description This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units of onboard complexesin ground-based air navigation when preflight ground check-service is made. The transport management at thousands of small provincial airports in the former country is still unfortunate. The same situation is in Northern and central Central Asia, Northern Caucasian and Trans-Caucasian Mountains, oriented to small civil and agricultural services airports, etc. Everywhere the phaseand line voltage amplitude unbalance can reach between 10-15% at the settlement’s power tiny transformer or generator and there are thousands and thousands of such local «airports» [1, 6]. This paperhas been editing by a native speaker, Ms. Rachel Alcorn — our sincere thanks.
publisher Kamianets-Podilskyi National Ivan Ohiienko University
publishDate 2016
url http://mcm-tech.kpnu.edu.ua/article/view/81958
work_keys_str_mv AT alizadaparviz parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication
AT tuncaynejar parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication
AT ozturksalihbaris parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication
AT mamedovhavar parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication
AT abdullaevs parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication
first_indexed 2024-04-08T14:58:32Z
last_indexed 2024-04-08T14:58:32Z
_version_ 1795779002768556032