PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION)
This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units...
Збережено в:
Видавець: | Kamianets-Podilskyi National Ivan Ohiienko University |
---|---|
Дата: | 2016 |
Автори: | , , , , |
Формат: | Стаття |
Мова: | English |
Опубліковано: |
Kamianets-Podilskyi National Ivan Ohiienko University
2016
|
Онлайн доступ: | http://mcm-tech.kpnu.edu.ua/article/view/81958 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Репозиторії
Mathematical and computer modelling. Series: Technical sciencesid |
mcmtechkpnueduua-article-81958 |
---|---|
record_format |
ojs |
spelling |
mcmtechkpnueduua-article-819582019-03-06T10:39:37Z PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) Ali Zada, Parviz Tuncay, Nejar Ozturk, Salih Baris Mamedov, Havar Abdullaev, S. This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units of onboard complexesin ground-based air navigation when preflight ground check-service is made. The transport management at thousands of small provincial airports in the former country is still unfortunate. The same situation is in Northern and central Central Asia, Northern Caucasian and Trans-Caucasian Mountains, oriented to small civil and agricultural services airports, etc. Everywhere the phaseand line voltage amplitude unbalance can reach between 10-15% at the settlement’s power tiny transformer or generator and there are thousands and thousands of such local «airports» [1, 6]. This paperhas been editing by a native speaker, Ms. Rachel Alcorn — our sincere thanks. Kamianets-Podilskyi National Ivan Ohiienko University 2016-04-20 Article Article application/pdf http://mcm-tech.kpnu.edu.ua/article/view/81958 10.32626/2308-5916.2016-13.5-16 Mathematical and computer modelling. Series: Technical sciences; 2016: Mathematical and computer modelling. Series: Technical sciences. Issue 13; 5-16 Математичне та комп'ютерне моделювання. Серія: Технічні науки ; 2016: Математичне та комп'ютерне моделювання. Серія: Технічні науки. Випуск 13; 5-16 2308-5916 10.32626/2308-5916.2016-13 en http://mcm-tech.kpnu.edu.ua/article/view/81958/77612 Авторське право (c) 2021 Математичне та комп'ютерне моделювання. Серія: Технічні науки |
institution |
Mathematical and computer modelling. Series: Technical sciences |
collection |
OJS |
language |
English |
format |
Article |
author |
Ali Zada, Parviz Tuncay, Nejar Ozturk, Salih Baris Mamedov, Havar Abdullaev, S. |
spellingShingle |
Ali Zada, Parviz Tuncay, Nejar Ozturk, Salih Baris Mamedov, Havar Abdullaev, S. PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
author_facet |
Ali Zada, Parviz Tuncay, Nejar Ozturk, Salih Baris Mamedov, Havar Abdullaev, S. |
author_sort |
Ali Zada, Parviz |
title |
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
title_short |
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
title_full |
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
title_fullStr |
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
title_full_unstemmed |
PARAMETRICAL METHOD OF LOW-FREQUENCY HARMONICS SUPPRESSION IN RECTIFIER’S OUTPUT VOLTAGE UNDER SUPPLY VOLTAGE UNBALANCES (MATHEMATICAL MODEL, STUDY AND INDUSTRIAL APPLICATION) |
title_sort |
parametrical method of low-frequency harmonics suppression in rectifier’s output voltage under supply voltage unbalances (mathematical model, study and industrial application) |
description |
This paper deals with using an original and pure electronic method for low-frequency harmonic suppression with wide industrial realization and application, in place of the usually heavy inductive, low-frequency harmonic filters. One of the main applications was made for small land power supply units of onboard complexesin ground-based air navigation when preflight ground check-service is made. The transport management at thousands of small provincial airports in the former country is still unfortunate. The same situation is in Northern and central Central Asia, Northern Caucasian and Trans-Caucasian Mountains, oriented to small civil and agricultural services airports, etc. Everywhere the phaseand line voltage amplitude unbalance can reach between 10-15% at the settlement’s power tiny transformer or generator and there are thousands and thousands of such local «airports» [1, 6]. This paperhas been editing by a native speaker, Ms. Rachel Alcorn — our sincere thanks. |
publisher |
Kamianets-Podilskyi National Ivan Ohiienko University |
publishDate |
2016 |
url |
http://mcm-tech.kpnu.edu.ua/article/view/81958 |
work_keys_str_mv |
AT alizadaparviz parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication AT tuncaynejar parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication AT ozturksalihbaris parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication AT mamedovhavar parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication AT abdullaevs parametricalmethodoflowfrequencyharmonicssuppressioninrectifiersoutputvoltageundersupplyvoltageunbalancesmathematicalmodelstudyandindustrialapplication |
first_indexed |
2024-04-08T14:58:32Z |
last_indexed |
2024-04-08T14:58:32Z |
_version_ |
1795779002768556032 |