Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak

Tokamak plasma modes were analyzed using the Fast Fourier Transform (FFT) in presence of hot limiter biasing system in the IR-T1 Tokamak. Fourier analysis is reliable technique for mode detection in tokamaks. For this purpose we used a poloidal array of Mirnov coils and hot limiter biasing system. A...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2013
Main Authors: Ghoranneviss, M., Salar Elahi, A., van Oost, G., Arvin, R., Mohammadi, S.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2013
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/109257
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak / M. Ghoranneviss, A. Salar Elahi, G. van Oost, R. Arvin, S. Mohammadi // Вопросы атомной науки и техники. — 2013. — № 1. — С. 8-11. — Бібліогр.: 7 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-109257
record_format dspace
spelling Ghoranneviss, M.
Salar Elahi, A.
van Oost, G.
Arvin, R.
Mohammadi, S.
2016-11-21T21:44:19Z
2016-11-21T21:44:19Z
2013
2013
Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak / M. Ghoranneviss, A. Salar Elahi, G. van Oost, R. Arvin, S. Mohammadi // Вопросы атомной науки и техники. — 2013. — № 1. — С. 8-11. — Бібліогр.: 7 назв. — англ.
1562-6016
PACS: 52.55.Fa
https://nasplib.isofts.kiev.ua/handle/123456789/109257
Tokamak plasma modes were analyzed using the Fast Fourier Transform (FFT) in presence of hot limiter biasing system in the IR-T1 Tokamak. Fourier analysis is reliable technique for mode detection in tokamaks. For this purpose we used a poloidal array of Mirnov coils and hot limiter biasing system. After Fourier analysis of Mirnov coils data in presence of hot biased limiter, Power Spectral Density (PSD) diagram was plotted. PSD describes how the power of a signal is distributed with frequency. In this contribution we also determined edge safety factor and safety factor from Fourier based derived mode numbers q = m/n. We obtained the maximum MHD activity using power spectrum at the frequency 33 kHz. Also the edge safety factor was determined less than 3, and the values of obtained safety factor from the mode numbers are between 2 ≤ q ≤ 5. Results show that hot limiter biasing can be used for increasing the plasma safety factor.
Моды плазмы токамака анализировались с использованием быстрого преобразования Фурье (БПФ) при наличии системы подачи напряжения на горячий лимитер в токамаке IR-T1. Использовалась полоидальная схема расположения катушек Мирнова. С помощью Фурье-анализа данных катушек Мирнова была построена диаграмма спектральной плотности мощности (СПМ), описывающая распределение мощности сигнала с частотой. Были определены величины q на краю плазмы и по данным Фурье-анализа (как отношение мод: q=m/n). Максимум активности МГД оказался на частоте 33 кГц; на краю величина q≤ 3, а найденная из номеров гармоник − 2 ≤ q ≤ 5. Результаты показали, что подача напряжения на лимитер может использоваться для увеличения плазменного коэффициента надежности.
Моди плазми токамака аналізувалися з використанням швидкого перетворення Фур'є (ШПФ) за наявності системи подачі напруги на гарячий лімітер у токамаці IR-T1. Використовувалась полоїдальна схема розміщення котушок Мірнова. За допомогою Фур'є-аналізу даних з котушок Мірнова була побудована діаграма спектральної щільності потужності (СЩП), яка описує розподіл потужності сигналу з частотою. Були визначені величини q на краю плазми і по даним Фур'є-аналізу (як відношення мод: q = m/n). Максимум активності МГД виявився на частоті 33 кГц; на краю величина q ≤ 3, а знайдена з номерів гармонік – 2 ≤ q ≤ 5. Результати показали, що подача напруги на лімітер може використовуватися для збільшення плазмового коефіцієнта надійності.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Магнитное удержание
Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
Управление модами пристеночной плазмы при подаче напряжения на лимитер в токамаке IR-T1
Управління модами крайової плазми за допомогою подачі напруги на лімітер у токамаці IR-T1
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
spellingShingle Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
Ghoranneviss, M.
Salar Elahi, A.
van Oost, G.
Arvin, R.
Mohammadi, S.
Магнитное удержание
title_short Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
title_full Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
title_fullStr Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
title_full_unstemmed Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak
title_sort control of the edge plasma modes by hot limiter biasing in the ir-t1 tokamak
author Ghoranneviss, M.
Salar Elahi, A.
van Oost, G.
Arvin, R.
Mohammadi, S.
author_facet Ghoranneviss, M.
Salar Elahi, A.
van Oost, G.
Arvin, R.
Mohammadi, S.
topic Магнитное удержание
topic_facet Магнитное удержание
publishDate 2013
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Управление модами пристеночной плазмы при подаче напряжения на лимитер в токамаке IR-T1
Управління модами крайової плазми за допомогою подачі напруги на лімітер у токамаці IR-T1
description Tokamak plasma modes were analyzed using the Fast Fourier Transform (FFT) in presence of hot limiter biasing system in the IR-T1 Tokamak. Fourier analysis is reliable technique for mode detection in tokamaks. For this purpose we used a poloidal array of Mirnov coils and hot limiter biasing system. After Fourier analysis of Mirnov coils data in presence of hot biased limiter, Power Spectral Density (PSD) diagram was plotted. PSD describes how the power of a signal is distributed with frequency. In this contribution we also determined edge safety factor and safety factor from Fourier based derived mode numbers q = m/n. We obtained the maximum MHD activity using power spectrum at the frequency 33 kHz. Also the edge safety factor was determined less than 3, and the values of obtained safety factor from the mode numbers are between 2 ≤ q ≤ 5. Results show that hot limiter biasing can be used for increasing the plasma safety factor. Моды плазмы токамака анализировались с использованием быстрого преобразования Фурье (БПФ) при наличии системы подачи напряжения на горячий лимитер в токамаке IR-T1. Использовалась полоидальная схема расположения катушек Мирнова. С помощью Фурье-анализа данных катушек Мирнова была построена диаграмма спектральной плотности мощности (СПМ), описывающая распределение мощности сигнала с частотой. Были определены величины q на краю плазмы и по данным Фурье-анализа (как отношение мод: q=m/n). Максимум активности МГД оказался на частоте 33 кГц; на краю величина q≤ 3, а найденная из номеров гармоник − 2 ≤ q ≤ 5. Результаты показали, что подача напряжения на лимитер может использоваться для увеличения плазменного коэффициента надежности. Моди плазми токамака аналізувалися з використанням швидкого перетворення Фур'є (ШПФ) за наявності системи подачі напруги на гарячий лімітер у токамаці IR-T1. Використовувалась полоїдальна схема розміщення котушок Мірнова. За допомогою Фур'є-аналізу даних з котушок Мірнова була побудована діаграма спектральної щільності потужності (СЩП), яка описує розподіл потужності сигналу з частотою. Були визначені величини q на краю плазми і по даним Фур'є-аналізу (як відношення мод: q = m/n). Максимум активності МГД виявився на частоті 33 кГц; на краю величина q ≤ 3, а знайдена з номерів гармонік – 2 ≤ q ≤ 5. Результати показали, що подача напруги на лімітер може використовуватися для збільшення плазмового коефіцієнта надійності.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/109257
citation_txt Control of the edge plasma modes by hot limiter biasing in the IR-T1 tokamak / M. Ghoranneviss, A. Salar Elahi, G. van Oost, R. Arvin, S. Mohammadi // Вопросы атомной науки и техники. — 2013. — № 1. — С. 8-11. — Бібліогр.: 7 назв. — англ.
work_keys_str_mv AT ghorannevissm controloftheedgeplasmamodesbyhotlimiterbiasingintheirt1tokamak
AT salarelahia controloftheedgeplasmamodesbyhotlimiterbiasingintheirt1tokamak
AT vanoostg controloftheedgeplasmamodesbyhotlimiterbiasingintheirt1tokamak
AT arvinr controloftheedgeplasmamodesbyhotlimiterbiasingintheirt1tokamak
AT mohammadis controloftheedgeplasmamodesbyhotlimiterbiasingintheirt1tokamak
AT ghorannevissm upravleniemodamipristenočnoiplazmypripodačenaprâženiânalimitervtokamakeirt1
AT salarelahia upravleniemodamipristenočnoiplazmypripodačenaprâženiânalimitervtokamakeirt1
AT vanoostg upravleniemodamipristenočnoiplazmypripodačenaprâženiânalimitervtokamakeirt1
AT arvinr upravleniemodamipristenočnoiplazmypripodačenaprâženiânalimitervtokamakeirt1
AT mohammadis upravleniemodamipristenočnoiplazmypripodačenaprâženiânalimitervtokamakeirt1
AT ghorannevissm upravlínnâmodamikraiovoíplazmizadopomogoûpodačínapruginalímíterutokamacíirt1
AT salarelahia upravlínnâmodamikraiovoíplazmizadopomogoûpodačínapruginalímíterutokamacíirt1
AT vanoostg upravlínnâmodamikraiovoíplazmizadopomogoûpodačínapruginalímíterutokamacíirt1
AT arvinr upravlínnâmodamikraiovoíplazmizadopomogoûpodačínapruginalímíterutokamacíirt1
AT mohammadis upravlínnâmodamikraiovoíplazmizadopomogoûpodačínapruginalímíterutokamacíirt1
first_indexed 2025-12-02T11:54:18Z
last_indexed 2025-12-02T11:54:18Z
_version_ 1850862437834686464