The Langmuir probe modeling in ion-beam plasma

The mathematical model of single cylindrical Langmuir probe describing dependence of ion current gathered by the probe on the basic parameters of ion-beam plasma, such as probe potential, cold and beam ion densities, relation between ion and electron tempe­ra­tures is built. The model covers wide pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2003
Hauptverfasser: Antonova, T.N., Dudin, S.V., Farenik, V.I.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2003
Schriftenreihe:Вопросы атомной науки и техники
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/110614
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:The Langmuir probe modeling in ion-beam plasma / T.N. Antonova, S.V. Dudin, V.I. Farenik // Вопросы атомной науки и техники. — 2003. — № 1. — С. 147-149. — Бібліогр.: 12 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:The mathematical model of single cylindrical Langmuir probe describing dependence of ion current gathered by the probe on the basic parameters of ion-beam plasma, such as probe potential, cold and beam ion densities, relation between ion and electron tempe­ra­tures is built. The model covers wide parameters range of the ion-beam plasma, particularly the whole range typical for technological ion-beam systems. The results of numerical calculations are presented for the probe current versus probe dimensions and potential as well as the plasma parameters. The analytical expression for the ion current (modification of the Bohm formula) is derived for the large probe limit. For the numerical results the approximation formula is constructed, simplifying practical usage of the results.