X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra

Primary and Compton scattered radiation spectra from radioactive source ²⁴¹Am were measured in various geometry and for various targets. Spectral lines intensity of characteristic X-ray radiation (CXR), Compton and Rayleigh scattering are defined. The back scattering peak for a line 59.54 keV was ex...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2011
Main Authors: Bochek, G.L., Deiev, O.S., Maslov, N.I., Voloshyn, V.K.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2011
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/111134
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra / G.L.Bochek, O.S.Deiev, N.I.Maslov, V.K.Voloshyn // Вопросы атомной науки и техники. — 2011. — № 3. — С. 42-49. — Бібліогр.: 12 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-111134
record_format dspace
spelling Bochek, G.L.
Deiev, O.S.
Maslov, N.I.
Voloshyn, V.K.
2017-01-08T15:05:56Z
2017-01-08T15:05:56Z
2011
X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra / G.L.Bochek, O.S.Deiev, N.I.Maslov, V.K.Voloshyn // Вопросы атомной науки и техники. — 2011. — № 3. — С. 42-49. — Бібліогр.: 12 назв. — англ.
1562-6016
PACS: 07.85.Fv, 61.80.Cb
https://nasplib.isofts.kiev.ua/handle/123456789/111134
Primary and Compton scattered radiation spectra from radioactive source ²⁴¹Am were measured in various geometry and for various targets. Spectral lines intensity of characteristic X-ray radiation (CXR), Compton and Rayleigh scattering are defined. The back scattering peak for a line 59.54 keV was explored. X-ray quanta were registered by the packaged Si detector 300mm and input Al foil 10mm thicknesses. Radiation interaction with targets and detector atoms was simulated in software code GEANT 4 (LE). Simulated spectra, quanta registration efficiency and secondary calculated radiation spectra at 90º...160º are compared with experimentally measured energy distributions.
Виміряні прямі і комптонівськи розсіяні спектри від радіоактивного джерела ²⁴¹Am в різній геометрії для різних мішеней. Визначені інтенсивності рентгенівських ліній характеристичного рентгенівського випромінювання (ХРІ), комптонівського і релеєвського розсіяння в розсіяних спектрах. Вивчався пік зворотнього розсіювання для лінії 59.54 кeВ. Рентгенівські кванти реєструвалися корпусованим Si - детектором товщиною 300 мкм і вхідною фольгою Al товщиною 10 мкм. У програмному коді GEANT 4 (LE) моделювалася взаємодія випромінювання з атомами мішені і детектора. Розраховані спектри випромінювання ²⁴¹Am, ефективність реєстрації квантів, спектри вторинного випромінювання, розсіяного під кутами 90º...160º, порівнюються з первинними енергетичними розподілами.
Измерены прямые и комптоновски рассеянные спектры излучения от радиоактивного источника ²⁴¹Am в различной геометрии для различных мишеней. Определены интенсивности рентгеновских линий характеристического рентгеновского излучения (ХРИ), комптоновского и рэлеевского рассеяния в рассеянных спектрах. Изучался пик обратного рассеяния для линии 59.54 кэВ. Рентгеновские кванты регистрировались корпусированным Si - детектором толщиной 300 мкм и входной Al фольгой толщиной 10 мкм. В программном коде GEANT 4 (LE) моделировалось взаимодействие излучения с атомами мишени и детектора. Расчетные спектры излучения ²⁴¹Am, эффективность регистрации квантов и спектры вторичного излучения, рассеянного под углами 90º...160º, сравниваются с экспериментально измеренными энергетическими распределениями.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Ядернo-физические методы и обработка данных
X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
Вiдноснi iнтенсивностi лiнiй рентгенiвського випромiнювання в залежностi вiд ефективностi детектора, товщин фольг i корпусiв для первинних та розсiяних спектрiв
Относительные интенсивности линий рентгеновского излучения в зависимости от эффективности детектора, толщин фольг и корпусов для первичных и рассеянных спектров
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
spellingShingle X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
Bochek, G.L.
Deiev, O.S.
Maslov, N.I.
Voloshyn, V.K.
Ядернo-физические методы и обработка данных
title_short X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
title_full X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
title_fullStr X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
title_full_unstemmed X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
title_sort x-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra
author Bochek, G.L.
Deiev, O.S.
Maslov, N.I.
Voloshyn, V.K.
author_facet Bochek, G.L.
Deiev, O.S.
Maslov, N.I.
Voloshyn, V.K.
topic Ядернo-физические методы и обработка данных
topic_facet Ядернo-физические методы и обработка данных
publishDate 2011
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Вiдноснi iнтенсивностi лiнiй рентгенiвського випромiнювання в залежностi вiд ефективностi детектора, товщин фольг i корпусiв для первинних та розсiяних спектрiв
Относительные интенсивности линий рентгеновского излучения в зависимости от эффективности детектора, толщин фольг и корпусов для первичных и рассеянных спектров
description Primary and Compton scattered radiation spectra from radioactive source ²⁴¹Am were measured in various geometry and for various targets. Spectral lines intensity of characteristic X-ray radiation (CXR), Compton and Rayleigh scattering are defined. The back scattering peak for a line 59.54 keV was explored. X-ray quanta were registered by the packaged Si detector 300mm and input Al foil 10mm thicknesses. Radiation interaction with targets and detector atoms was simulated in software code GEANT 4 (LE). Simulated spectra, quanta registration efficiency and secondary calculated radiation spectra at 90º...160º are compared with experimentally measured energy distributions. Виміряні прямі і комптонівськи розсіяні спектри від радіоактивного джерела ²⁴¹Am в різній геометрії для різних мішеней. Визначені інтенсивності рентгенівських ліній характеристичного рентгенівського випромінювання (ХРІ), комптонівського і релеєвського розсіяння в розсіяних спектрах. Вивчався пік зворотнього розсіювання для лінії 59.54 кeВ. Рентгенівські кванти реєструвалися корпусованим Si - детектором товщиною 300 мкм і вхідною фольгою Al товщиною 10 мкм. У програмному коді GEANT 4 (LE) моделювалася взаємодія випромінювання з атомами мішені і детектора. Розраховані спектри випромінювання ²⁴¹Am, ефективність реєстрації квантів, спектри вторинного випромінювання, розсіяного під кутами 90º...160º, порівнюються з первинними енергетичними розподілами. Измерены прямые и комптоновски рассеянные спектры излучения от радиоактивного источника ²⁴¹Am в различной геометрии для различных мишеней. Определены интенсивности рентгеновских линий характеристического рентгеновского излучения (ХРИ), комптоновского и рэлеевского рассеяния в рассеянных спектрах. Изучался пик обратного рассеяния для линии 59.54 кэВ. Рентгеновские кванты регистрировались корпусированным Si - детектором толщиной 300 мкм и входной Al фольгой толщиной 10 мкм. В программном коде GEANT 4 (LE) моделировалось взаимодействие излучения с атомами мишени и детектора. Расчетные спектры излучения ²⁴¹Am, эффективность регистрации квантов и спектры вторичного излучения, рассеянного под углами 90º...160º, сравниваются с экспериментально измеренными энергетическими распределениями.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/111134
citation_txt X-ray lines relative intensity depending on detector efficiency, foils and cases thickness for primary and scattered spectra / G.L.Bochek, O.S.Deiev, N.I.Maslov, V.K.Voloshyn // Вопросы атомной науки и техники. — 2011. — № 3. — С. 42-49. — Бібліогр.: 12 назв. — англ.
work_keys_str_mv AT bochekgl xraylinesrelativeintensitydependingondetectorefficiencyfoilsandcasesthicknessforprimaryandscatteredspectra
AT deievos xraylinesrelativeintensitydependingondetectorefficiencyfoilsandcasesthicknessforprimaryandscatteredspectra
AT maslovni xraylinesrelativeintensitydependingondetectorefficiencyfoilsandcasesthicknessforprimaryandscatteredspectra
AT voloshynvk xraylinesrelativeintensitydependingondetectorefficiencyfoilsandcasesthicknessforprimaryandscatteredspectra
AT bochekgl vidnosniintensivnostiliniirentgenivsʹkogoviprominûvannâvzaležnostividefektivnostidetektoratovŝinfolʹgikorpusivdlâpervinnihtarozsiânihspektriv
AT deievos vidnosniintensivnostiliniirentgenivsʹkogoviprominûvannâvzaležnostividefektivnostidetektoratovŝinfolʹgikorpusivdlâpervinnihtarozsiânihspektriv
AT maslovni vidnosniintensivnostiliniirentgenivsʹkogoviprominûvannâvzaležnostividefektivnostidetektoratovŝinfolʹgikorpusivdlâpervinnihtarozsiânihspektriv
AT voloshynvk vidnosniintensivnostiliniirentgenivsʹkogoviprominûvannâvzaležnostividefektivnostidetektoratovŝinfolʹgikorpusivdlâpervinnihtarozsiânihspektriv
AT bochekgl otnositelʹnyeintensivnostiliniirentgenovskogoizlučeniâvzavisimostiotéffektivnostidetektoratolŝinfolʹgikorpusovdlâpervičnyhirasseânnyhspektrov
AT deievos otnositelʹnyeintensivnostiliniirentgenovskogoizlučeniâvzavisimostiotéffektivnostidetektoratolŝinfolʹgikorpusovdlâpervičnyhirasseânnyhspektrov
AT maslovni otnositelʹnyeintensivnostiliniirentgenovskogoizlučeniâvzavisimostiotéffektivnostidetektoratolŝinfolʹgikorpusovdlâpervičnyhirasseânnyhspektrov
AT voloshynvk otnositelʹnyeintensivnostiliniirentgenovskogoizlučeniâvzavisimostiotéffektivnostidetektoratolŝinfolʹgikorpusovdlâpervičnyhirasseânnyhspektrov
first_indexed 2025-11-30T20:46:11Z
last_indexed 2025-11-30T20:46:11Z
_version_ 1850858479034564608