X-ray source with variable photons energy for medicine applications

The prospect of creation of the X-ray source with tunable wavelength on the base of a middle energy accelerator and mosaic crystals are analyzed. It is proved, that due to the contribution of diffracted bremsstrahlung, the mosaic crystals provide the essentially greater yield of hard radiation (w ≥...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2009
Main Authors: Shatokhin, R.A., Vnukov, I.E., Zhandarmov, Yu.V.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2009
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/111267
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:X-ray source with variable photons energy for medicine applications / R.A. Shatokhin, I.E. Vnukov, Yu.V. Zhandarmov // Вопросы атомной науки и техники. — 2009. — № 3. — С. 113-119. — Бібліогр.: 23 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862721426310561792
author Shatokhin, R.A.
Vnukov, I.E.
Zhandarmov, Yu.V.
author_facet Shatokhin, R.A.
Vnukov, I.E.
Zhandarmov, Yu.V.
citation_txt X-ray source with variable photons energy for medicine applications / R.A. Shatokhin, I.E. Vnukov, Yu.V. Zhandarmov // Вопросы атомной науки и техники. — 2009. — № 3. — С. 113-119. — Бібліогр.: 23 назв. — англ.
collection DSpace DC
container_title Вопросы атомной науки и техники
description The prospect of creation of the X-ray source with tunable wavelength on the base of a middle energy accelerator and mosaic crystals are analyzed. It is proved, that due to the contribution of diffracted bremsstrahlung, the mosaic crystals provide the essentially greater yield of hard radiation (w ≥ 20 keV), than perfect crystals. It is shown, that using a traditional scheme with one crystal for X-ray generation isn't acceptable for medicine applications. Double-crystal scheme is offered and analyzed, in which one crystal is located on the electrons beam, and another is used for monochromatization and parallel moving of the X-ray beam. It provides suppression of background bremsstrahlung, and there is no need to move the object when change the photons energy. Проведено аналіз перспективи створення джерела рентгенівського випромінювання зі змінюваною єнергією на основі електронного прискорювача середніх енергій та мозаїчних кристалів. Доведено, що мозаїчні кристали забезпечують більший вихід жорсткого випромінювання, порівнянно з ідеальними. Показано, що схема генерації випромінювання з одним кристалом неприйнятна із-за фону гальмового випромінювання. Запропонована та проаналізована схема з двома кристалами, де один розміщений під пучком електронів, а другий використовується для монохроматизації та паралельного переносу, чим забезпечується зменшення фону та відсутність необхідності переміщення об'єкта опромінювання при зміні енергії фотонів. Анализируются перспективы создания источника рентгеновского излучения с перестраиваемой энергией на основе электронного ускорителя средних энергий и мозаичных кристаллов. Доказано, что мозаичные кристаллы обеспечивают больший выход жёсткого излучения, чем совершенные. Показано, что однокристальная схема генерации излучения не применима для использования в медицине из-за фона тормозного излучения. Предложена и анализируется двухкристальная схема, где один из кристаллов установлен на пучке электронов, а другой используется для монохроматизации излучения и параллельного переноса, что обеспечивает подавление фона и отсутствие необходимости перемещения объекта облучения при изменении энергии фотонов.
first_indexed 2025-12-07T18:30:59Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-111267
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-12-07T18:30:59Z
publishDate 2009
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Shatokhin, R.A.
Vnukov, I.E.
Zhandarmov, Yu.V.
2017-01-09T10:52:17Z
2017-01-09T10:52:17Z
2009
X-ray source with variable photons energy for medicine applications / R.A. Shatokhin, I.E. Vnukov, Yu.V. Zhandarmov // Вопросы атомной науки и техники. — 2009. — № 3. — С. 113-119. — Бібліогр.: 23 назв. — англ.
1562-6016
PACS: 07.85.Fv
https://nasplib.isofts.kiev.ua/handle/123456789/111267
The prospect of creation of the X-ray source with tunable wavelength on the base of a middle energy accelerator and mosaic crystals are analyzed. It is proved, that due to the contribution of diffracted bremsstrahlung, the mosaic crystals provide the essentially greater yield of hard radiation (w ≥ 20 keV), than perfect crystals. It is shown, that using a traditional scheme with one crystal for X-ray generation isn't acceptable for medicine applications. Double-crystal scheme is offered and analyzed, in which one crystal is located on the electrons beam, and another is used for monochromatization and parallel moving of the X-ray beam. It provides suppression of background bremsstrahlung, and there is no need to move the object when change the photons energy.
Проведено аналіз перспективи створення джерела рентгенівського випромінювання зі змінюваною єнергією на основі електронного прискорювача середніх енергій та мозаїчних кристалів. Доведено, що мозаїчні кристали забезпечують більший вихід жорсткого випромінювання, порівнянно з ідеальними. Показано, що схема генерації випромінювання з одним кристалом неприйнятна із-за фону гальмового випромінювання. Запропонована та проаналізована схема з двома кристалами, де один розміщений під пучком електронів, а другий використовується для монохроматизації та паралельного переносу, чим забезпечується зменшення фону та відсутність необхідності переміщення об'єкта опромінювання при зміні енергії фотонів.
Анализируются перспективы создания источника рентгеновского излучения с перестраиваемой энергией на основе электронного ускорителя средних энергий и мозаичных кристаллов. Доказано, что мозаичные кристаллы обеспечивают больший выход жёсткого излучения, чем совершенные. Показано, что однокристальная схема генерации излучения не применима для использования в медицине из-за фона тормозного излучения. Предложена и анализируется двухкристальная схема, где один из кристаллов установлен на пучке электронов, а другой используется для монохроматизации излучения и параллельного переноса, что обеспечивает подавление фона и отсутствие необходимости перемещения объекта облучения при изменении энергии фотонов.
The work is fulfilled with partial support of RFBR
 (grants 05-02-17648 and 08-02-00816a) and the programme
 of inner grants of BelSU.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Электродинамика
X-ray source with variable photons energy for medicine applications
Джерело рентгенівського випромінювання зі змінюваною єнергією для потреб медицини
Источник рентгеновского излучения с перестраиваемой энергией для медицинских целей
Article
published earlier
spellingShingle X-ray source with variable photons energy for medicine applications
Shatokhin, R.A.
Vnukov, I.E.
Zhandarmov, Yu.V.
Электродинамика
title X-ray source with variable photons energy for medicine applications
title_alt Джерело рентгенівського випромінювання зі змінюваною єнергією для потреб медицини
Источник рентгеновского излучения с перестраиваемой энергией для медицинских целей
title_full X-ray source with variable photons energy for medicine applications
title_fullStr X-ray source with variable photons energy for medicine applications
title_full_unstemmed X-ray source with variable photons energy for medicine applications
title_short X-ray source with variable photons energy for medicine applications
title_sort x-ray source with variable photons energy for medicine applications
topic Электродинамика
topic_facet Электродинамика
url https://nasplib.isofts.kiev.ua/handle/123456789/111267
work_keys_str_mv AT shatokhinra xraysourcewithvariablephotonsenergyformedicineapplications
AT vnukovie xraysourcewithvariablephotonsenergyformedicineapplications
AT zhandarmovyuv xraysourcewithvariablephotonsenergyformedicineapplications
AT shatokhinra džerelorentgenívsʹkogovipromínûvannâzízmínûvanoûênergíêûdlâpotrebmedicini
AT vnukovie džerelorentgenívsʹkogovipromínûvannâzízmínûvanoûênergíêûdlâpotrebmedicini
AT zhandarmovyuv džerelorentgenívsʹkogovipromínûvannâzízmínûvanoûênergíêûdlâpotrebmedicini
AT shatokhinra istočnikrentgenovskogoizlučeniâsperestraivaemoiénergieidlâmedicinskihcelei
AT vnukovie istočnikrentgenovskogoizlučeniâsperestraivaemoiénergieidlâmedicinskihcelei
AT zhandarmovyuv istočnikrentgenovskogoizlučeniâsperestraivaemoiénergieidlâmedicinskihcelei