Measurements of LET spectra of the JINR phasotron radiotherapy proton beam

Biological action of ionizing radiation can be described using the quantity called the Linear Energy Transfer (LET). The LET belongs to one of most important radiobiological quantities. In our paper, we focused on measurement of the LET spectra in the clinical proton beam of the Laboratory of Nuclea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2013
Hauptverfasser: Kubančák, J., Molokanov, A.G.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2013
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/111791
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Measurements of LET spectra of the JINR phasotron radiotherapy proton beam / J. Kubančák, A.G. Molokanov // Вопросы атомной науки и техники. — 2013. — № 6. — С. 90-92. — Бібліогр.: 5 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-111791
record_format dspace
spelling Kubančák, J.
Molokanov, A.G.
2017-01-14T19:50:47Z
2017-01-14T19:50:47Z
2013
Measurements of LET spectra of the JINR phasotron radiotherapy proton beam / J. Kubančák, A.G. Molokanov // Вопросы атомной науки и техники. — 2013. — № 6. — С. 90-92. — Бібліогр.: 5 назв. — англ.
1562-6016
PACS: 61.80.-x; 61.80.Jh
https://nasplib.isofts.kiev.ua/handle/123456789/111791
Biological action of ionizing radiation can be described using the quantity called the Linear Energy Transfer (LET). The LET belongs to one of most important radiobiological quantities. In our paper, we focused on measurement of the LET spectra in the clinical proton beam of the Laboratory of Nuclear Problems (LNP) of the Joint Institute for Nuclear Research (JINR). The LET was calculated on the base of measurement with the Liulin-4C silicon semiconductor energy deposits spectrometer in several points along the depth-dose curve for different beam setups. Results can be used mainly for obtaining more detailed information about the radiation quality during the radiobiological experiments.
Біологічний вплив іонізуючого випромінювання визначається величиною лінійної передачі енергії (ЛПЕ). Від величини ЛПЕ залежить механізм взаємодії клітин з випромінюванням. Представлено результати вимірювань спектрів ЛПЕ радіотерапевтичного пучка протонів фазотрона ЛЯП ОІЯД. ЛПЕ розраховувалися на основі вимірів кремнієвим напівпровідниковим спектрометром LIULIN-4C у різних точках глибинного дозного розподілу. Результати можуть бути використані для отримання більш детальної інформації про якість випромінювання протонного пучка при радіобіологічних дослідженнях.
Биологическое воздействие ионизирующего излучения определяется величиной линейной передачи энергии (ЛПЭ). От величины ЛПЭ зависит механизм взаимодействия клеток с излучением. Представлены результаты измерений спектров ЛПЭ радиотерапевтического пучка протонов фазотрона ЛЯП ОИЯИ. ЛПЭ рассчитывались на основе измерений кремниевым полупроводниковым спектрометром LIULIN-4C в различных точках глубинного дозного распределения. Результаты могут быть использованы для получения более детальной информации о качестве излучения протонного пучка при радиобиологических исследованиях.
This work was partially supported with the internal grant of the Czech Technical University number SGS12/200/OHK4/3T/14 and with the INGO II project of the Ministry of Education, Youth and Sports.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Элементы ускорителей
Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
Вимір спектрів ЛПЕ радіотерапевтичного протонного пучка фазотрона ЛЯП ОІЯД
Измерение спектров ЛПЭ радиотерапевтического протонного пучка фазотрона ЛЯП ОИЯИ
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
spellingShingle Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
Kubančák, J.
Molokanov, A.G.
Элементы ускорителей
title_short Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
title_full Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
title_fullStr Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
title_full_unstemmed Measurements of LET spectra of the JINR phasotron radiotherapy proton beam
title_sort measurements of let spectra of the jinr phasotron radiotherapy proton beam
author Kubančák, J.
Molokanov, A.G.
author_facet Kubančák, J.
Molokanov, A.G.
topic Элементы ускорителей
topic_facet Элементы ускорителей
publishDate 2013
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Вимір спектрів ЛПЕ радіотерапевтичного протонного пучка фазотрона ЛЯП ОІЯД
Измерение спектров ЛПЭ радиотерапевтического протонного пучка фазотрона ЛЯП ОИЯИ
description Biological action of ionizing radiation can be described using the quantity called the Linear Energy Transfer (LET). The LET belongs to one of most important radiobiological quantities. In our paper, we focused on measurement of the LET spectra in the clinical proton beam of the Laboratory of Nuclear Problems (LNP) of the Joint Institute for Nuclear Research (JINR). The LET was calculated on the base of measurement with the Liulin-4C silicon semiconductor energy deposits spectrometer in several points along the depth-dose curve for different beam setups. Results can be used mainly for obtaining more detailed information about the radiation quality during the radiobiological experiments. Біологічний вплив іонізуючого випромінювання визначається величиною лінійної передачі енергії (ЛПЕ). Від величини ЛПЕ залежить механізм взаємодії клітин з випромінюванням. Представлено результати вимірювань спектрів ЛПЕ радіотерапевтичного пучка протонів фазотрона ЛЯП ОІЯД. ЛПЕ розраховувалися на основі вимірів кремнієвим напівпровідниковим спектрометром LIULIN-4C у різних точках глибинного дозного розподілу. Результати можуть бути використані для отримання більш детальної інформації про якість випромінювання протонного пучка при радіобіологічних дослідженнях. Биологическое воздействие ионизирующего излучения определяется величиной линейной передачи энергии (ЛПЭ). От величины ЛПЭ зависит механизм взаимодействия клеток с излучением. Представлены результаты измерений спектров ЛПЭ радиотерапевтического пучка протонов фазотрона ЛЯП ОИЯИ. ЛПЭ рассчитывались на основе измерений кремниевым полупроводниковым спектрометром LIULIN-4C в различных точках глубинного дозного распределения. Результаты могут быть использованы для получения более детальной информации о качестве излучения протонного пучка при радиобиологических исследованиях.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/111791
citation_txt Measurements of LET spectra of the JINR phasotron radiotherapy proton beam / J. Kubančák, A.G. Molokanov // Вопросы атомной науки и техники. — 2013. — № 6. — С. 90-92. — Бібліогр.: 5 назв. — англ.
work_keys_str_mv AT kubancakj measurementsofletspectraofthejinrphasotronradiotherapyprotonbeam
AT molokanovag measurementsofletspectraofthejinrphasotronradiotherapyprotonbeam
AT kubancakj vimírspektrívlperadíoterapevtičnogoprotonnogopučkafazotronalâpoíâd
AT molokanovag vimírspektrívlperadíoterapevtičnogoprotonnogopučkafazotronalâpoíâd
AT kubancakj izmereniespektrovlpéradioterapevtičeskogoprotonnogopučkafazotronalâpoiâi
AT molokanovag izmereniespektrovlpéradioterapevtičeskogoprotonnogopučkafazotronalâpoiâi
first_indexed 2025-12-07T15:16:55Z
last_indexed 2025-12-07T15:16:55Z
_version_ 1850863114596122624