Experimental Investigation on the Tensile Strength of Composite Laminates Containing Open and Filled Holes
An experimental study is performed to evaluate the effects of clamping pressure, friction, and washer size on the static performance of composite laminates with open and bolt-filled holes. The static tensile strength and failure behavior of composite laminates with an open hole and a bolt-fill...
Saved in:
| Date: | 2014 |
|---|---|
| Main Authors: | , , |
| Format: | Article |
| Language: | English |
| Published: |
Інститут проблем міцності ім. Г.С. Писаренко НАН України
2014
|
| Series: | Проблемы прочности |
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/112718 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Experimental Investigation on the Tensile Strength of Composite Laminates Containing Open and Filled Holes / X.L. Fan, W.J. Qin, T. Suo // Проблемы прочности. — 2014. — № 2. — С. 141-146. — Бібліогр.: 13 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| Summary: | An experimental study is performed to evaluate
the effects of clamping pressure, friction, and
washer size on the static performance of composite
laminates with open and bolt-filled holes.
The static tensile strength and failure behavior
of composite laminates with an open hole and a
bolt-filled hole are analyzed and compared. Experimental
results show that the static tensile
strength of composite laminates is sensitive to
pre-existing damage of both open- or filled-hole
laminates. In contrast, a comparison between
the experimental results of open- and filled-hole
specimens proved that whether the hole is open
or filled has a feeble influence on the tensile-tensile
fatigue strength of studied composite laminates.
In comparison, however, it is found that
the inserted washer size, bolt clamping force,
and friction force strongly affect the tensile
strength of open- and filled-hole composite laminates.
Moreover, application of thicker washers
and hi-lock bolt will significantly increase
the static strength and fatigue life of composite
laminates with a bolt-filled hole. |
|---|