Recent developments in the ISTTOK heavy ion beam diagnostic

The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma e...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2016
Main Authors: Nedzelskiy, I.S., Malaquias, A., Henriques, R.B., Sharma, R.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2016
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/115467
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862529151965069312
author Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
author_facet Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
citation_txt Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ.
collection DSpace DC
container_title Вопросы атомной науки и техники
description The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma electrons and separated from the primaries due to the confining magnetic field of the plasma device. The resulting secondary ions are collected outside the plasma. The plasma parameters that can be measured by the HIBD are: the plasma electron density and temperature, and the electric and magnetic potentials. On the small tokamak ISTTOK (R = 0.46 m, a = 0.085 m, B = 0.5 T, Ip = 4…6 kA, = 5 × 10¹⁸ m ⁻³ , Te = 120 eV), the HIBD is based on a 20 keV Xe⁺ (or Cs⁺ ) beam injector and a multiple cell array detector (MCAD) collecting a fan of secondary Xe²⁺ (or Cs²⁺) ions emerging from the plasma along the primary beam trajectory. This paper describes the recent developments and improvements in the ISTTOK HIBD secondary beam detection. The capabilities of new detection system are illustrated by recent results of ISTTOK plasma MHD activity and electrode biasing studies. The on going developments of the multichannel multi-slit 90o cylindrical energy analyzer for the plasma potential and its fluctuations measurements and a novel approach of the HIBD use in real-time vertical plasma position control are also considered. Диагностика пучком тяжёлых ионов (ДПТИ) является мощным инструментом в исследованиях горячей плазмы в термоядерных установках с магнитным удержанием. Инжектируемый в плазму первичный пучок однозарядных положительных ионов ионизируется в двухзарядное состояние в столкновениях с электронами плазмы. В магнитном поле плазменной установки результирующие вторичные ионы отделяются от первичного пучка и детектируются вне плазмы. Измеряемые ДПТИ параметры плазмы включают плотность, температуру электронов, электрический и магнитный потенциалы. На малом токамаке ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5 × 10¹⁸ м ⁻³, Te = 120 эВ) ДПТИ состоит из 20 кэВ инжектора Xe ⁺ (или Cs⁺) пучка и мультиколлекторного детектора (МКД) вторичных Хе²⁺ (или Cs²⁺ионов, выходящих из плазмы вдоль траектории первичного пучка. Описываются изменения и улучшения детекторной системы ДПТИ на токамаке ISTTOK. Возможности новой детекторной системы иллюстрируются недавними результатами исследований МГД-активности и поляризации плазмы. Рассматриваются также разработка многоканального мультищелевого 90o цилиндрического анализатора энергии для измерений потенциала плазмы и его флуктуаций и новый подход использования ДПТИ для контроля вертикального положения плазмы в режиме реального времени. Діагностика пучком важких іонів (ДПВІ) є потужним інструментом у дослідженнях гарячої плазми в термоядерних установках з магнітним утриманням. Iнжектований в плазму первинний пучок однозарядних позитивних іонів іонізується в двозарядний стан у зіткненнях з електронами плазми. У магнітному полі плазмової установки результуючі вторинні іони відокремлюються від первинного пучка і фіксуються поза плазми. Вимірювані ДПВІ параметри плазми включають щільність, температуру електронів, електричний і магнітний потенціали. На малому токамацi ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5×10¹⁸ м ⁻³, Te = 120 еВ) ДПВІ складається з 20 кеВ інжектора Xe+ (або Cs+ ) пучка і мультиколекторного детектора (МКД) вторинних Хе²⁺ (або Cs²⁺) іонів, які виходять з плазми уздовж траєкторії первинного пучка. Описуються зміни і поліпшення детекторной системи ДПВІ на токамацi ISTTOK. Можливості нової детекторної системи ілюструються недавніми результатами досліджень МГД-активності і поляризації плазми. Розглядаються також розробка багатоканального мультищілинного 90o циліндричного аналізатора енергії для вимірювань потенціалу плазми та його флуктуацій і новий підхід використання ДПВІ для контролю вертикального положення плазми в режимі реального часу
first_indexed 2025-11-24T02:21:37Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-115467
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-11-24T02:21:37Z
publishDate 2016
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
2017-04-05T06:46:24Z
2017-04-05T06:46:24Z
2016
Recent developments in the ISTTOK heavy ion beam diagnostic / I.S. Nedzelskiy, A. Malaquias, R.B. Henriques, R. Sharma // Вопросы атомной науки и техники. — 2016. — № 6. — С. 297-301. — Бібліогр.: 9 назв. — англ.
1562-6016
PACS: 52.55.Fa, 52.70.-m
https://nasplib.isofts.kiev.ua/handle/123456789/115467
The heavy ion beam diagnostic (HIBD) presents a powerful tool for investigations of hot plasmas in thermonuclear devices with magnetic confinement. When injected into the plasma, the primary probing beam of singly charged positive ions is ionized to a doubly charged state by impact with the plasma electrons and separated from the primaries due to the confining magnetic field of the plasma device. The resulting secondary ions are collected outside the plasma. The plasma parameters that can be measured by the HIBD are: the plasma electron density and temperature, and the electric and magnetic potentials. On the small tokamak ISTTOK (R = 0.46 m, a = 0.085 m, B = 0.5 T, Ip = 4…6 kA, = 5 × 10¹⁸ m ⁻³ , Te = 120 eV), the HIBD is based on a 20 keV Xe⁺ (or Cs⁺ ) beam injector and a multiple cell array detector (MCAD) collecting a fan of secondary Xe²⁺ (or Cs²⁺) ions emerging from the plasma along the primary beam trajectory. This paper describes the recent developments and improvements in the ISTTOK HIBD secondary beam detection. The capabilities of new detection system are illustrated by recent results of ISTTOK plasma MHD activity and electrode biasing studies. The on going developments of the multichannel multi-slit 90o cylindrical energy analyzer for the plasma potential and its fluctuations measurements and a novel approach of the HIBD use in real-time vertical plasma position control are also considered.
Диагностика пучком тяжёлых ионов (ДПТИ) является мощным инструментом в исследованиях горячей плазмы в термоядерных установках с магнитным удержанием. Инжектируемый в плазму первичный пучок однозарядных положительных ионов ионизируется в двухзарядное состояние в столкновениях с электронами плазмы. В магнитном поле плазменной установки результирующие вторичные ионы отделяются от первичного пучка и детектируются вне плазмы. Измеряемые ДПТИ параметры плазмы включают плотность, температуру электронов, электрический и магнитный потенциалы. На малом токамаке ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5 × 10¹⁸ м ⁻³, Te = 120 эВ) ДПТИ состоит из 20 кэВ инжектора Xe ⁺ (или Cs⁺) пучка и мультиколлекторного детектора (МКД) вторичных Хе²⁺ (или Cs²⁺ионов, выходящих из плазмы вдоль траектории первичного пучка. Описываются изменения и улучшения детекторной системы ДПТИ на токамаке ISTTOK. Возможности новой детекторной системы иллюстрируются недавними результатами исследований МГД-активности и поляризации плазмы. Рассматриваются также разработка многоканального мультищелевого 90o цилиндрического анализатора энергии для измерений потенциала плазмы и его флуктуаций и новый подход использования ДПТИ для контроля вертикального положения плазмы в режиме реального времени.
Діагностика пучком важких іонів (ДПВІ) є потужним інструментом у дослідженнях гарячої плазми в термоядерних установках з магнітним утриманням. Iнжектований в плазму первинний пучок однозарядних позитивних іонів іонізується в двозарядний стан у зіткненнях з електронами плазми. У магнітному полі плазмової установки результуючі вторинні іони відокремлюються від первинного пучка і фіксуються поза плазми. Вимірювані ДПВІ параметри плазми включають щільність, температуру електронів, електричний і магнітний потенціали. На малому токамацi ISTTOK (R = 0,46 м, а = 0,085 м, В = 0,5 Тл, Ip = 4…6 кА, = 5×10¹⁸ м ⁻³, Te = 120 еВ) ДПВІ складається з 20 кеВ інжектора Xe+ (або Cs+ ) пучка і мультиколекторного детектора (МКД) вторинних Хе²⁺ (або Cs²⁺) іонів, які виходять з плазми уздовж траєкторії первинного пучка. Описуються зміни і поліпшення детекторной системи ДПВІ на токамацi ISTTOK. Можливості нової детекторної системи ілюструються недавніми результатами досліджень МГД-активності і поляризації плазми. Розглядаються також розробка багатоканального мультищілинного 90o циліндричного аналізатора енергії для вимірювань потенціалу плазми та його флуктуацій і новий підхід використання ДПВІ для контролю вертикального положення плазми в режимі реального часу
IPFN activities received financial support from
 ”Fundação para a Ciência e Tecnologia” through project
 UID/FIS/50010/2013.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Plasma diagnostics
Recent developments in the ISTTOK heavy ion beam diagnostic
Современное состояние диагностики плазмы пучка тяжёлых ионов на токамаке ISTTOK
Сучасний стан діагностики плазми пучка важких іонів на токамацi ISTTOK
Article
published earlier
spellingShingle Recent developments in the ISTTOK heavy ion beam diagnostic
Nedzelskiy, I.S.
Malaquias, A.
Henriques, R.B.
Sharma, R.
Plasma diagnostics
title Recent developments in the ISTTOK heavy ion beam diagnostic
title_alt Современное состояние диагностики плазмы пучка тяжёлых ионов на токамаке ISTTOK
Сучасний стан діагностики плазми пучка важких іонів на токамацi ISTTOK
title_full Recent developments in the ISTTOK heavy ion beam diagnostic
title_fullStr Recent developments in the ISTTOK heavy ion beam diagnostic
title_full_unstemmed Recent developments in the ISTTOK heavy ion beam diagnostic
title_short Recent developments in the ISTTOK heavy ion beam diagnostic
title_sort recent developments in the isttok heavy ion beam diagnostic
topic Plasma diagnostics
topic_facet Plasma diagnostics
url https://nasplib.isofts.kiev.ua/handle/123456789/115467
work_keys_str_mv AT nedzelskiyis recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT malaquiasa recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT henriquesrb recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT sharmar recentdevelopmentsintheisttokheavyionbeamdiagnostic
AT nedzelskiyis sovremennoesostoâniediagnostikiplazmypučkatâželyhionovnatokamakeisttok
AT malaquiasa sovremennoesostoâniediagnostikiplazmypučkatâželyhionovnatokamakeisttok
AT henriquesrb sovremennoesostoâniediagnostikiplazmypučkatâželyhionovnatokamakeisttok
AT sharmar sovremennoesostoâniediagnostikiplazmypučkatâželyhionovnatokamakeisttok
AT nedzelskiyis sučasniistandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT malaquiasa sučasniistandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT henriquesrb sučasniistandíagnostikiplazmipučkavažkihíonívnatokamaciisttok
AT sharmar sučasniistandíagnostikiplazmipučkavažkihíonívnatokamaciisttok