Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts
It is known that the most widely used method to control internal strains is the
 optical polarization method. However, the sources of polarized radiation are the most
 problem issue of this method. There are some difficulties in using this method when
 testing large-scale opt...
Saved in:
| Published in: | Semiconductor Physics Quantum Electronics & Optoelectronics |
|---|---|
| Date: | 2013 |
| Main Authors: | , |
| Format: | Article |
| Language: | English |
| Published: |
Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України
2013
|
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/117736 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Use of radiation from PC screen for non-destructive controlling
 the internal strains in transparent parts / V.P. Maslov, N.V. Kachur // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2013. — Т. 16, № 3. — С. 297-299. — Бібліогр.: 9 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862734710888726528 |
|---|---|
| author | Maslov, V.P. Kachur, N.V. |
| author_facet | Maslov, V.P. Kachur, N.V. |
| citation_txt | Use of radiation from PC screen for non-destructive controlling
 the internal strains in transparent parts / V.P. Maslov, N.V. Kachur // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2013. — Т. 16, № 3. — С. 297-299. — Бібліогр.: 9 назв. — англ. |
| collection | DSpace DC |
| container_title | Semiconductor Physics Quantum Electronics & Optoelectronics |
| description | It is known that the most widely used method to control internal strains is the
optical polarization method. However, the sources of polarized radiation are the most
problem issue of this method. There are some difficulties in using this method when
testing large-scale optical parts, diameters of which exceed 500 mm. To choose an
optical source suitable for solving these tasks, we have analyzed the design of liquidcrystal
screens and ascertained the possibility to use their polarized radiation in tests of
internal strains in optical parts of large dimensions. Adduced below are the results of
investigations of internal strains in parts of sapphire and organic glass.
|
| first_indexed | 2025-12-07T19:45:03Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-117736 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| issn | 1560-8034 |
| language | English |
| last_indexed | 2025-12-07T19:45:03Z |
| publishDate | 2013 |
| publisher | Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України |
| record_format | dspace |
| spelling | Maslov, V.P. Kachur, N.V. 2017-05-26T14:10:36Z 2017-05-26T14:10:36Z 2013 Use of radiation from PC screen for non-destructive controlling
 the internal strains in transparent parts / V.P. Maslov, N.V. Kachur // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2013. — Т. 16, № 3. — С. 297-299. — Бібліогр.: 9 назв. — англ. 1560-8034 PACS 42.79.Ci https://nasplib.isofts.kiev.ua/handle/123456789/117736 It is known that the most widely used method to control internal strains is the
 optical polarization method. However, the sources of polarized radiation are the most
 problem issue of this method. There are some difficulties in using this method when
 testing large-scale optical parts, diameters of which exceed 500 mm. To choose an
 optical source suitable for solving these tasks, we have analyzed the design of liquidcrystal
 screens and ascertained the possibility to use their polarized radiation in tests of
 internal strains in optical parts of large dimensions. Adduced below are the results of
 investigations of internal strains in parts of sapphire and organic glass. en Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України Semiconductor Physics Quantum Electronics & Optoelectronics Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts Article published earlier |
| spellingShingle | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts Maslov, V.P. Kachur, N.V. |
| title | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts |
| title_full | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts |
| title_fullStr | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts |
| title_full_unstemmed | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts |
| title_short | Use of radiation from PC screen for non-destructive controlling the internal strains in transparent parts |
| title_sort | use of radiation from pc screen for non-destructive controlling the internal strains in transparent parts |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/117736 |
| work_keys_str_mv | AT maslovvp useofradiationfrompcscreenfornondestructivecontrollingtheinternalstrainsintransparentparts AT kachurnv useofradiationfrompcscreenfornondestructivecontrollingtheinternalstrainsintransparentparts |