Portable three-wavelength standard for energy unit of pulse laser radiation
New instrument for applications in metrological measurements of laser pulse energy is presented. Due to its parameters, it can be used as a standard for energy unit of pulse laser radiation. The instrument consists of a control unit, three different sources of laser radiation, two detectors of optic...
Gespeichert in:
| Veröffentlicht in: | Semiconductor Physics Quantum Electronics & Optoelectronics |
|---|---|
| Datum: | 2004 |
| Hauptverfasser: | , , , |
| Format: | Artikel |
| Sprache: | Englisch |
| Veröffentlicht: |
Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України
2004
|
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/118177 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Portable three-wavelength standard for energy unit of pulse laser radiation / J. Owsik, A. Zarwalska, Ja. Janucki, V.B. Samoylov // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2004. — Т. 7, № 2. — С. 202-206. — Бібліогр.: 8 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862740087771496448 |
|---|---|
| author | Owsik, J. Zarwalska, A. Janucki, Ja. Samoylov, V.B. |
| author_facet | Owsik, J. Zarwalska, A. Janucki, Ja. Samoylov, V.B. |
| citation_txt | Portable three-wavelength standard for energy unit of pulse laser radiation / J. Owsik, A. Zarwalska, Ja. Janucki, V.B. Samoylov // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2004. — Т. 7, № 2. — С. 202-206. — Бібліогр.: 8 назв. — англ. |
| collection | DSpace DC |
| container_title | Semiconductor Physics Quantum Electronics & Optoelectronics |
| description | New instrument for applications in metrological measurements of laser pulse energy is presented. Due to its parameters, it can be used as a standard for energy unit of pulse laser radiation. The instrument consists of a control unit, three different sources of laser radiation, two detectors of optical signal, and a laptop. The whole system can be easily transported enabling one to perform measurements in situ, at customers, and not only in laboratory conditions. A method of measurements used in the standard operation is described. Main characteristics of the standard are shown. Methods enabling calculations of measurement uncertainties during laser energy meter calibration by means of our standard are also presented.
|
| first_indexed | 2025-12-07T20:12:33Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-118177 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| issn | 1560-8034 |
| language | English |
| last_indexed | 2025-12-07T20:12:33Z |
| publishDate | 2004 |
| publisher | Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України |
| record_format | dspace |
| spelling | Owsik, J. Zarwalska, A. Janucki, Ja. Samoylov, V.B. 2017-05-29T05:38:28Z 2017-05-29T05:38:28Z 2004 Portable three-wavelength standard for energy unit of pulse laser radiation / J. Owsik, A. Zarwalska, Ja. Janucki, V.B. Samoylov // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2004. — Т. 7, № 2. — С. 202-206. — Бібліогр.: 8 назв. — англ. 1560-8034 PACS: 06.20.Fn, 07.60.-j https://nasplib.isofts.kiev.ua/handle/123456789/118177 New instrument for applications in metrological measurements of laser pulse energy is presented. Due to its parameters, it can be used as a standard for energy unit of pulse laser radiation. The instrument consists of a control unit, three different sources of laser radiation, two detectors of optical signal, and a laptop. The whole system can be easily transported enabling one to perform measurements in situ, at customers, and not only in laboratory conditions. A method of measurements used in the standard operation is described. Main characteristics of the standard are shown. Methods enabling calculations of measurement uncertainties during laser energy meter calibration by means of our standard are also presented. en Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України Semiconductor Physics Quantum Electronics & Optoelectronics Portable three-wavelength standard for energy unit of pulse laser radiation Article published earlier |
| spellingShingle | Portable three-wavelength standard for energy unit of pulse laser radiation Owsik, J. Zarwalska, A. Janucki, Ja. Samoylov, V.B. |
| title | Portable three-wavelength standard for energy unit of pulse laser radiation |
| title_full | Portable three-wavelength standard for energy unit of pulse laser radiation |
| title_fullStr | Portable three-wavelength standard for energy unit of pulse laser radiation |
| title_full_unstemmed | Portable three-wavelength standard for energy unit of pulse laser radiation |
| title_short | Portable three-wavelength standard for energy unit of pulse laser radiation |
| title_sort | portable three-wavelength standard for energy unit of pulse laser radiation |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/118177 |
| work_keys_str_mv | AT owsikj portablethreewavelengthstandardforenergyunitofpulselaserradiation AT zarwalskaa portablethreewavelengthstandardforenergyunitofpulselaserradiation AT januckija portablethreewavelengthstandardforenergyunitofpulselaserradiation AT samoylovvb portablethreewavelengthstandardforenergyunitofpulselaserradiation |