Effect of the structure of polarimeter characteristic matrix on light polarization measurements
In the paper, we carried out the comparative analysis of three polarimeters
 among the most usable their variants: (i) Stokes polarimeter based on phenomenological
 definition of Stokes parameters; (ii) Stokes polarimeter based on the method of four
 intensities; (iii) Stokes...
Saved in:
| Published in: | Semiconductor Physics Quantum Electronics & Optoelectronics |
|---|---|
| Date: | 2009 |
| Main Authors: | , , , |
| Format: | Article |
| Language: | English |
| Published: |
Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України
2009
|
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/118872 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Effect of the structure of polarimeter characteristic matrix
 on light polarization measurements / S.N. Savenkov, Ye.A. Oberemok, O.S. Klimov, О.I. Barchuk // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2009. — Т. 12, № 3. — С.264-271. — Бібліогр.: 26 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862623768801705984 |
|---|---|
| author | Savenkov, S.N. Oberemok, Ye.A. Klimov, O.S. Barchuk, О.I. |
| author_facet | Savenkov, S.N. Oberemok, Ye.A. Klimov, O.S. Barchuk, О.I. |
| citation_txt | Effect of the structure of polarimeter characteristic matrix
 on light polarization measurements / S.N. Savenkov, Ye.A. Oberemok, O.S. Klimov, О.I. Barchuk // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2009. — Т. 12, № 3. — С.264-271. — Бібліогр.: 26 назв. — англ. |
| collection | DSpace DC |
| container_title | Semiconductor Physics Quantum Electronics & Optoelectronics |
| description | In the paper, we carried out the comparative analysis of three polarimeters
among the most usable their variants: (i) Stokes polarimeter based on phenomenological
definition of Stokes parameters; (ii) Stokes polarimeter based on the method of four
intensities; (iii) Stokes dynamic polarimeter. We show that, since the accuracy in
determination of individual Stokes parameter is different for different types of
polarimeters, and, therewith, it depends on polarization of input light. All that strongly
motivates the choice of type of polarimeter to provide minimum errors in determination
of polarization parameters (ellipticity angle ε, azimuth β, and degree of polarization P).
|
| first_indexed | 2025-12-07T13:30:55Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-118872 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| issn | 1560-8034 |
| language | English |
| last_indexed | 2025-12-07T13:30:55Z |
| publishDate | 2009 |
| publisher | Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України |
| record_format | dspace |
| spelling | Savenkov, S.N. Oberemok, Ye.A. Klimov, O.S. Barchuk, О.I. 2017-05-31T19:46:09Z 2017-05-31T19:46:09Z 2009 Effect of the structure of polarimeter characteristic matrix
 on light polarization measurements / S.N. Savenkov, Ye.A. Oberemok, O.S. Klimov, О.I. Barchuk // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2009. — Т. 12, № 3. — С.264-271. — Бібліогр.: 26 назв. — англ. 1560-8034 PACS 07.60.Fs https://nasplib.isofts.kiev.ua/handle/123456789/118872 In the paper, we carried out the comparative analysis of three polarimeters
 among the most usable their variants: (i) Stokes polarimeter based on phenomenological
 definition of Stokes parameters; (ii) Stokes polarimeter based on the method of four
 intensities; (iii) Stokes dynamic polarimeter. We show that, since the accuracy in
 determination of individual Stokes parameter is different for different types of
 polarimeters, and, therewith, it depends on polarization of input light. All that strongly
 motivates the choice of type of polarimeter to provide minimum errors in determination
 of polarization parameters (ellipticity angle ε, azimuth β, and degree of polarization P). en Інститут фізики напівпровідників імені В.Є. Лашкарьова НАН України Semiconductor Physics Quantum Electronics & Optoelectronics Effect of the structure of polarimeter characteristic matrix on light polarization measurements Article published earlier |
| spellingShingle | Effect of the structure of polarimeter characteristic matrix on light polarization measurements Savenkov, S.N. Oberemok, Ye.A. Klimov, O.S. Barchuk, О.I. |
| title | Effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| title_full | Effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| title_fullStr | Effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| title_full_unstemmed | Effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| title_short | Effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| title_sort | effect of the structure of polarimeter characteristic matrix on light polarization measurements |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/118872 |
| work_keys_str_mv | AT savenkovsn effectofthestructureofpolarimetercharacteristicmatrixonlightpolarizationmeasurements AT oberemokyea effectofthestructureofpolarimetercharacteristicmatrixonlightpolarizationmeasurements AT klimovos effectofthestructureofpolarimetercharacteristicmatrixonlightpolarizationmeasurements AT barchukoi effectofthestructureofpolarimetercharacteristicmatrixonlightpolarizationmeasurements |