Digital X-ray imaging using matrix detectors and composite screens
In the paper it has been shown the possibility to use large area dispersed scintillators based on ZnSe:Al scintillation screens having a maximum luminescence in photoabsorption of zinc selenide instead of X-ray film for defectoscopy of metal products. Experimental data on influence of X-ray absorpti...
Saved in:
| Published in: | Functional Materials |
|---|---|
| Date: | 2014 |
| Main Author: | |
| Format: | Article |
| Language: | English |
| Published: |
НТК «Інститут монокристалів» НАН України
2014
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/120366 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Digital X-ray imaging using matrix detectors and composite screens / E.F. Voronkin // Functional Materials. — 2014. — Т. 21, № 1. — С. 112-118. — Бібліогр.: 10 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-120366 |
|---|---|
| record_format |
dspace |
| spelling |
Voronkin, E.F. 2017-06-12T06:27:49Z 2017-06-12T06:27:49Z 2014 Digital X-ray imaging using matrix detectors and composite screens / E.F. Voronkin // Functional Materials. — 2014. — Т. 21, № 1. — С. 112-118. — Бібліогр.: 10 назв. — англ. 1027-5495 DOI: dx.doi.org/10.15407/fm21.01.112 https://nasplib.isofts.kiev.ua/handle/123456789/120366 In the paper it has been shown the possibility to use large area dispersed scintillators based on ZnSe:Al scintillation screens having a maximum luminescence in photoabsorption of zinc selenide instead of X-ray film for defectoscopy of metal products. Experimental data on influence of X-ray absorption by the samples using scintillation screens based on zinc selenide chalcogenide scintillator and ERS-S-2A on the thickness of the sample at an acceleration voltage in kV are reported. Prospects of using the zinc selenide composite screens in imaging of biological objects are shown, which proves the possibility of using these screens in tomographic medical systems. en НТК «Інститут монокристалів» НАН України Functional Materials Devices and instruments Digital X-ray imaging using matrix detectors and composite screens Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
Digital X-ray imaging using matrix detectors and composite screens |
| spellingShingle |
Digital X-ray imaging using matrix detectors and composite screens Voronkin, E.F. Devices and instruments |
| title_short |
Digital X-ray imaging using matrix detectors and composite screens |
| title_full |
Digital X-ray imaging using matrix detectors and composite screens |
| title_fullStr |
Digital X-ray imaging using matrix detectors and composite screens |
| title_full_unstemmed |
Digital X-ray imaging using matrix detectors and composite screens |
| title_sort |
digital x-ray imaging using matrix detectors and composite screens |
| author |
Voronkin, E.F. |
| author_facet |
Voronkin, E.F. |
| topic |
Devices and instruments |
| topic_facet |
Devices and instruments |
| publishDate |
2014 |
| language |
English |
| container_title |
Functional Materials |
| publisher |
НТК «Інститут монокристалів» НАН України |
| format |
Article |
| description |
In the paper it has been shown the possibility to use large area dispersed scintillators based on ZnSe:Al scintillation screens having a maximum luminescence in photoabsorption of zinc selenide instead of X-ray film for defectoscopy of metal products. Experimental data on influence of X-ray absorption by the samples using scintillation screens based on zinc selenide chalcogenide scintillator and ERS-S-2A on the thickness of the sample at an acceleration voltage in kV are reported. Prospects of using the zinc selenide composite screens in imaging of biological objects are shown, which proves the possibility of using these screens in tomographic medical systems.
|
| issn |
1027-5495 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/120366 |
| citation_txt |
Digital X-ray imaging using matrix detectors and composite screens / E.F. Voronkin // Functional Materials. — 2014. — Т. 21, № 1. — С. 112-118. — Бібліогр.: 10 назв. — англ. |
| work_keys_str_mv |
AT voronkinef digitalxrayimagingusingmatrixdetectorsandcompositescreens |
| first_indexed |
2025-12-02T11:55:02Z |
| last_indexed |
2025-12-02T11:55:02Z |
| _version_ |
1850862437931155456 |