Mean kinetic energy and final state effects in liquid hydrogens from inelastic neutron scattering

We have measured, using the TOSCA spectrometer at ISIS, the neutron scattering spectrum of liquid para-hydrogen ( T = 19.3 K and n = 25.4 nm⁻³ ) and liquid ortho-deuterium ( T = 21.3 K and n = 25.2 nm⁻³ ). From the high-energy region of the spectrum, namely 40 meV < ~ω < 1 eV, where the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Condensed Matter Physics
Datum:2003
Hauptverfasser: Corradi, G., Colognesi, D., Celli, M., Zoppi, M.
Format: Artikel
Sprache:English
Veröffentlicht: Інститут фізики конденсованих систем НАН України 2003
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/120749
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Mean kinetic energy and final state effects in liquid hydrogens from inelastic neutron scattering / G. Corradi, D. Colognesi, M. Celli, M. Zoppi // Condensed Matter Physics. — 2003. — Т. 6, № 3(35). — С. 499-521. — Бібліогр.: 76 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:We have measured, using the TOSCA spectrometer at ISIS, the neutron scattering spectrum of liquid para-hydrogen ( T = 19.3 K and n = 25.4 nm⁻³ ) and liquid ortho-deuterium ( T = 21.3 K and n = 25.2 nm⁻³ ). From the high-energy region of the spectrum, namely 40 meV < ~ω < 1 eV, where the incoherent approximation for the center-of-mass motion applies, we have been able to extract the translational mean kinetic energy, which, as expected, turns out to be rather different from the classical values. However, significant deviations from the impulse approximation have been detected and the inclusion of some correction terms (accounting for the so-called final state effects) had to be accomplished in order to accurately describe the experimental spectra. The comparison of the present mean kinetic energy values with the available experimental and simulated data in the literature is quite good and confirms the excellent performances of TOSCA in the spectroscopic analysis of the condensed phases of liquid hydrogens. Використовуючи спектрометр TOSCA в ISIS нами було проведено вимірювання спектрів нейтронного розсіяння рідкого пара-водню (T = 19.3 K і n = 25.4 nm⁻³ ) і рідкого орто-дейтерію (T = 21.3 K і n = 25.2 nm⁻³ ). З високоенергетичної області спектру 40 meV < ~ω < 1 eV, де застосовується некогерентне наближення для руху центра мас, маємо можливість отримати трансляційну середню кінетичну енергію, значення якої, як ми і сподівалися, відрізняється від класичних значень. Проте, було відзначено сильні відхилення від імпульсного наближення і тому певні поправочні доданки (врахування т.зв. ефектів кінцевого стану) повинні бути взяті до розгляду для точного опису експериментальних спектрів. Порівняння наявних даних по середній кінетичній енергії з значеннями експериментальними чи з моделювань, доступними в літературі, є зовсім добрим і підтверджує високу якість процедури спектрального аналізу на спектрометрі TOSCA для конденсованих фаз рідких воднів.
ISSN:1607-324X