Application of electrodialytic pilot plant for fluoride removal

Removal of fluorine from water was investigated by electrodialysis method. In order to check the efficacy of ED unit, parameters like applied potential, pH; initial fluoride concentrations and flow rates were varied. Significant results were obtained with concentrations of less than 10 ppm. Results...

Повний опис

Збережено в:
Бібліографічні деталі
Опубліковано в: :Химия и технология воды
Дата:2011
Автори: Rangappa S. Keri, Kallappa M. Hosamani, Harisha R. Seetharama Reddy, Sanna Kotrappanavar Nataraj, Tejraj M. Aminabhavi
Формат: Стаття
Мова:English
Опубліковано: Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України 2011
Теми:
Онлайн доступ:https://nasplib.isofts.kiev.ua/handle/123456789/130658
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Application of electrodialytic pilot plant for fluoride removal / Rangappa S. Keri, Kallappa M. Hosamani, Harisha R. Seetharama Reddy, Sanna Kotrappanavar Nataraj, Tejraj M. Aminabhavi // Химия и технология воды. — 2011. — Т. 33, № 5. — С. 496-508. — Бібліогр.: 21 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-130658
record_format dspace
spelling Rangappa S. Keri
Kallappa M. Hosamani
Harisha R. Seetharama Reddy
Sanna Kotrappanavar Nataraj
Tejraj M. Aminabhavi
2018-02-18T17:09:21Z
2018-02-18T17:09:21Z
2011
Application of electrodialytic pilot plant for fluoride removal / Rangappa S. Keri, Kallappa M. Hosamani, Harisha R. Seetharama Reddy, Sanna Kotrappanavar Nataraj, Tejraj M. Aminabhavi // Химия и технология воды. — 2011. — Т. 33, № 5. — С. 496-508. — Бібліогр.: 21 назв. — англ.
0204-3556
https://nasplib.isofts.kiev.ua/handle/123456789/130658
628.161:546.16
Removal of fluorine from water was investigated by electrodialysis method. In order to check the efficacy of ED unit, parameters like applied potential, pH; initial fluoride concentrations and flow rates were varied. Significant results were obtained with concentrations of less than 10 ppm. Results were satisfactory in meeting the maximum contaminate level (MCL) of 0.01 ppm for fluoride. Effect of working parameters on energy consumption was investigated using ion-exchange membranes. Results of this study are useful for designing and operating different capacities of ED plants for recovering different ions. The ED plant was found to be satisfactory to produce a good quality drinking water from the simulated mixture by removing the unwanted ions.
Исследовано удаление фтора из воды методом электродиализа. Для проверки эффективности электродиализной установки варьировали приложенную разность потенциалов, начальную концентрацию фторида и скорость потока. Важные результаты были получены при начальной концентрации фторида <10 мг/дм3. С использованием ионообменных мембран исследовано влияние рабочих параметров на энергопотребление. Результаты данной работы будут полезны для разработки и планирования производительности электродиализной установки при выделении различных ионов. Электродиализная установка оказалась эффективной для получения питьевой воды хорошего качества из модельных растворов путем удаления нежелательных ионов.
Досліджено видалення фтору з води методом електродіалізу. Для перевірки ефективності електродіалізної установки варіювали прикладену різницю потенціалів, початкову концентра цію фторидута швидкість потоку. Важливі результати були отримані при початковій концентрації фториду <10 мг/дм3. З використанням іонообмінних мембран досліджено вплив робочих параметрів на енергоспоживання. Результати цієї роботи будуть корисні длярозробки та планування продуктивності електродіалізної установки при виділенні різних іонів.Електродіалізна установка виявилася ефективною для отримання питної води хорошої якості з модельних розчинів шляхом видалення - небажаних іонів
This research work is financially supported by the Department of Science & Technology (DST), New Delhi - 110 016. (Ref. No SR/S1/OC-08/2005 dated 05-09-2005).
en
Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
Химия и технология воды
Технология водоподготовки и деминерализация вод
Application of electrodialytic pilot plant for fluoride removal
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Application of electrodialytic pilot plant for fluoride removal
spellingShingle Application of electrodialytic pilot plant for fluoride removal
Rangappa S. Keri
Kallappa M. Hosamani
Harisha R. Seetharama Reddy
Sanna Kotrappanavar Nataraj
Tejraj M. Aminabhavi
Технология водоподготовки и деминерализация вод
title_short Application of electrodialytic pilot plant for fluoride removal
title_full Application of electrodialytic pilot plant for fluoride removal
title_fullStr Application of electrodialytic pilot plant for fluoride removal
title_full_unstemmed Application of electrodialytic pilot plant for fluoride removal
title_sort application of electrodialytic pilot plant for fluoride removal
author Rangappa S. Keri
Kallappa M. Hosamani
Harisha R. Seetharama Reddy
Sanna Kotrappanavar Nataraj
Tejraj M. Aminabhavi
author_facet Rangappa S. Keri
Kallappa M. Hosamani
Harisha R. Seetharama Reddy
Sanna Kotrappanavar Nataraj
Tejraj M. Aminabhavi
topic Технология водоподготовки и деминерализация вод
topic_facet Технология водоподготовки и деминерализация вод
publishDate 2011
language English
container_title Химия и технология воды
publisher Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
format Article
description Removal of fluorine from water was investigated by electrodialysis method. In order to check the efficacy of ED unit, parameters like applied potential, pH; initial fluoride concentrations and flow rates were varied. Significant results were obtained with concentrations of less than 10 ppm. Results were satisfactory in meeting the maximum contaminate level (MCL) of 0.01 ppm for fluoride. Effect of working parameters on energy consumption was investigated using ion-exchange membranes. Results of this study are useful for designing and operating different capacities of ED plants for recovering different ions. The ED plant was found to be satisfactory to produce a good quality drinking water from the simulated mixture by removing the unwanted ions. Исследовано удаление фтора из воды методом электродиализа. Для проверки эффективности электродиализной установки варьировали приложенную разность потенциалов, начальную концентрацию фторида и скорость потока. Важные результаты были получены при начальной концентрации фторида <10 мг/дм3. С использованием ионообменных мембран исследовано влияние рабочих параметров на энергопотребление. Результаты данной работы будут полезны для разработки и планирования производительности электродиализной установки при выделении различных ионов. Электродиализная установка оказалась эффективной для получения питьевой воды хорошего качества из модельных растворов путем удаления нежелательных ионов. Досліджено видалення фтору з води методом електродіалізу. Для перевірки ефективності електродіалізної установки варіювали прикладену різницю потенціалів, початкову концентра цію фторидута швидкість потоку. Важливі результати були отримані при початковій концентрації фториду <10 мг/дм3. З використанням іонообмінних мембран досліджено вплив робочих параметрів на енергоспоживання. Результати цієї роботи будуть корисні длярозробки та планування продуктивності електродіалізної установки при виділенні різних іонів.Електродіалізна установка виявилася ефективною для отримання питної води хорошої якості з модельних розчинів шляхом видалення - небажаних іонів
issn 0204-3556
url https://nasplib.isofts.kiev.ua/handle/123456789/130658
citation_txt Application of electrodialytic pilot plant for fluoride removal / Rangappa S. Keri, Kallappa M. Hosamani, Harisha R. Seetharama Reddy, Sanna Kotrappanavar Nataraj, Tejraj M. Aminabhavi // Химия и технология воды. — 2011. — Т. 33, № 5. — С. 496-508. — Бібліогр.: 21 назв. — англ.
work_keys_str_mv AT rangappaskeri applicationofelectrodialyticpilotplantforfluorideremoval
AT kallappamhosamani applicationofelectrodialyticpilotplantforfluorideremoval
AT harisharseetharamareddy applicationofelectrodialyticpilotplantforfluorideremoval
AT sannakotrappanavarnataraj applicationofelectrodialyticpilotplantforfluorideremoval
AT tejrajmaminabhavi applicationofelectrodialyticpilotplantforfluorideremoval
first_indexed 2025-12-07T21:03:34Z
last_indexed 2025-12-07T21:03:34Z
_version_ 1850884923710242816