Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital
The investigated of the potable water treatment room and the sanitary facilities of patient boxes was held. The potable water treatment room had three collection points (ball valves), while in the sanitary facilities potable water was collected from the tap, shower, and the flush tank. A swab was ta...
Gespeichert in:
| Veröffentlicht in: | Химия и технология воды |
|---|---|
| Datum: | 2014 |
| Hauptverfasser: | , , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
2014
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/131043 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital / O. Holy, I. Matouskova, E. Juraskova // Химия и технология воды.— 2014.— Т. 36, № 5.— С. 458-466.— Бібліогр.: 25 назв.— англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-131043 |
|---|---|
| record_format |
dspace |
| spelling |
Holy, O. Matouskova, I. Juraskova, E. 2018-03-11T14:43:49Z 2018-03-11T14:43:49Z 2014 Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital / O. Holy, I. Matouskova, E. Juraskova // Химия и технология воды.— 2014.— Т. 36, № 5.— С. 458-466.— Бібліогр.: 25 назв.— англ. 0204-3556 https://nasplib.isofts.kiev.ua/handle/123456789/131043 The investigated of the potable water treatment room and the sanitary facilities of patient boxes was held. The potable water treatment room had three collection points (ball valves), while in the sanitary facilities potable water was collected from the tap, shower, and the flush tank. A swab was taken from the inside wall of the toilet tank. The samples and swabs of the flush tank water were Legionella pneumophila sg 1 and sg 6A positive. Disinfection of flush tanks with chlorine agents was recommended. We thank the medical and nursing staff of the Bone Marrow Transplant Units at the Olomouc University Hospital for their cooperation. Project supported by grant project nr. 801100021/39 - Surveillance of Infectious Complications in Hemato-Oncological Patients. en Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України Химия и технология воды Биологические методы очистки воды Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital |
| spellingShingle |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital Holy, O. Matouskova, I. Juraskova, E. Биологические методы очистки воды |
| title_short |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital |
| title_full |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital |
| title_fullStr |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital |
| title_full_unstemmed |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital |
| title_sort |
risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a czech university hospital |
| author |
Holy, O. Matouskova, I. Juraskova, E. |
| author_facet |
Holy, O. Matouskova, I. Juraskova, E. |
| topic |
Биологические методы очистки воды |
| topic_facet |
Биологические методы очистки воды |
| publishDate |
2014 |
| language |
English |
| container_title |
Химия и технология воды |
| publisher |
Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України |
| format |
Article |
| description |
The investigated of the potable water treatment room and the sanitary facilities of patient boxes was held. The potable water treatment room had three collection points (ball valves), while in the sanitary facilities potable water was collected from the tap, shower, and the flush tank. A swab was taken from the inside wall of the toilet tank. The samples and swabs of the flush tank water were Legionella pneumophila sg 1 and sg 6A positive. Disinfection of flush tanks with chlorine agents was recommended.
We thank the medical and nursing staff of the Bone Marrow Transplant Units at the Olomouc University Hospital for their cooperation. Project supported by grant project nr. 801100021/39 - Surveillance of Infectious Complications in Hemato-Oncological Patients.
|
| issn |
0204-3556 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/131043 |
| citation_txt |
Risk of hospital-acquired legionellosis from microbial contamination of potable water at a bone marrow transplantunit in a Czech university hospital / O. Holy, I. Matouskova, E. Juraskova // Химия и технология воды.— 2014.— Т. 36, № 5.— С. 458-466.— Бібліогр.: 25 назв.— англ. |
| work_keys_str_mv |
AT holyo riskofhospitalacquiredlegionellosisfrommicrobialcontaminationofpotablewateratabonemarrowtransplantunitinaczechuniversityhospital AT matouskovai riskofhospitalacquiredlegionellosisfrommicrobialcontaminationofpotablewateratabonemarrowtransplantunitinaczechuniversityhospital AT juraskovae riskofhospitalacquiredlegionellosisfrommicrobialcontaminationofpotablewateratabonemarrowtransplantunitinaczechuniversityhospital |
| first_indexed |
2025-12-07T20:15:01Z |
| last_indexed |
2025-12-07T20:15:01Z |
| _version_ |
1850881868844498944 |