On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography

As market proposal of various scintillators with different characteristics is rapidly increasing, it becomes more and more difficult to assess them from the viewpoint of the effects of this or that scintillator property upon parameters of digital X-ray radiography systems. Therefore, optimum choice...

Full description

Saved in:
Bibliographic Details
Published in:Functional Materials
Date:2004
Main Authors: Ryzhikov, V.D., Kozin, D.N.
Format: Article
Language:English
Published: НТК «Інститут монокристалів» НАН України 2004
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/135258
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography / V.D. Ryzhikov, D.N. Kozin // Functional Materials. — 2004. — Т. 11, № 1. — С. 205-209. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-135258
record_format dspace
spelling Ryzhikov, V.D.
Kozin, D.N.
2018-06-14T17:25:22Z
2018-06-14T17:25:22Z
2004
On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography / V.D. Ryzhikov, D.N. Kozin // Functional Materials. — 2004. — Т. 11, № 1. — С. 205-209. — Бібліогр.: 4 назв. — англ.
1027-5495
https://nasplib.isofts.kiev.ua/handle/123456789/135258
As market proposal of various scintillators with different characteristics is rapidly increasing, it becomes more and more difficult to assess them from the viewpoint of the effects of this or that scintillator property upon parameters of digital X-ray radiography systems. Therefore, optimum choice of scintillators for "scintillator-photodiode" (S-PD) type detectors is a very important aspect in the development and design of new radio -graphic systems. We propose a simple procedure for making this choice, which uses linear matrices of S-PD detectors. It allows evaluation of changes in the relative sensitivity of a radiographic system with variation of the movement speed of the inspected object and the radiation energy on the basis of amplitude-time characteristics of scintillators (decay time and afterglow, light output). Amplitude-time characteristics are presented for scintillat ors ZnSe(Te), Csl(TI), CdWO4. On the basis of these data, it is proposed to use ZnSe(Te) in the 20-100 keV range at object movement speed up to 10 cm/s, Csl(TI) — 90—500 keV up to 10 cm/s, CdWO4 150 keV at the speeds up to 500 cm/s.
В связи с увеличением количества предложении на рынке сцинтилляторов с различными характеристиками, трудно оценить их по влиянию тоИ или иноИ характеристики сцинтиллятора на параметры цифровоИ рентгенографической системы. Поэтому актуален подбор сцинтиллятора для детекторов типа сцинтиллятор-фотодиод (СЦ-ФД) при проектировании и создании рентгенографических систем. Нами предлагается простая методика выбора сцинтилляторов для цифровоИ радиографии, использующих линеИные матрицы детекторов типа СЦ-ФД. Она позволяет на основе амплитудно-временных характеристик сцинтиллятора (временные зависимости высвечивания и послесвечения, световыход) оценивать изменение относительноИ чувствительности радиографическоИ системы в целом при изменении скорости перемещения объекта и энергии ионизирующего излучения. Приводятся амплитудно-временные характеристики сцинтилляторов ZnSe(Te), Csl(TI), CdWO4. На основании этих данных предлагается использовать ZnSe(Te) в диапазоне 20-100 кэВ при скорости объекта не более 10 см/с, Csl(TI) — 90-500 кэВ до 10 см/с, CdWO4 150 кэВ при скорости до 500 см/с.
У зв’язку з підвищєною кількістю пропозиціИ на ринку сцинтиляторів з різними характеристиками, важко оцінити їх за впливом тієї чі іншої характеристики сцинтилятору на параметри цифрової рентгенографічної системи. Тому підбір сцинтилятора до детектора типу сцинтилятор-фотодіод (СЦ-ФД) при проектуванні та створенні рент-генографичних систем є актуальним. Нами пропонується проста методика вибору сцинтиляторів до цифрової радіографії, що використовують лініИну матрицю детекторів типу СЦ-ФД. Вона дозволяє на підставі амплітудно-часової характеристики сцинтилятора (часова залежність висвітлення та післясвітіння, світловихід) оцінювати зміну відносної чутливості радіографічної системи у цілому при зміні швидкості переміщення об’єкту та енергії іонізуючого випромінення. Наводяться амплітудно-часові характеристики сцинтиляторів ZnSe(Te), Csl(TI), CdWO4. На підставі цих даних пропонується застосовувати ZnSe(Te) в діапазоні 20-100 кеВ при швидкості об’єкту не більш ніж 10 см/с, Csl(TI) — 90-500 кеВ до 10 см/с, CdWO4 150 кеВ при швидкості до 500 см/с.
en
НТК «Інститут монокристалів» НАН України
Functional Materials
On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
Вибір сцинтилятора до детекторів типу сцинтилятор-фотодіод до цифрової радіграфії
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
spellingShingle On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
Ryzhikov, V.D.
Kozin, D.N.
title_short On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
title_full On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
title_fullStr On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
title_full_unstemmed On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
title_sort on the choice of scintillators for "scintillator-photodiode" detectors for digital radiography
author Ryzhikov, V.D.
Kozin, D.N.
author_facet Ryzhikov, V.D.
Kozin, D.N.
publishDate 2004
language English
container_title Functional Materials
publisher НТК «Інститут монокристалів» НАН України
format Article
title_alt Вибір сцинтилятора до детекторів типу сцинтилятор-фотодіод до цифрової радіграфії
description As market proposal of various scintillators with different characteristics is rapidly increasing, it becomes more and more difficult to assess them from the viewpoint of the effects of this or that scintillator property upon parameters of digital X-ray radiography systems. Therefore, optimum choice of scintillators for "scintillator-photodiode" (S-PD) type detectors is a very important aspect in the development and design of new radio -graphic systems. We propose a simple procedure for making this choice, which uses linear matrices of S-PD detectors. It allows evaluation of changes in the relative sensitivity of a radiographic system with variation of the movement speed of the inspected object and the radiation energy on the basis of amplitude-time characteristics of scintillators (decay time and afterglow, light output). Amplitude-time characteristics are presented for scintillat ors ZnSe(Te), Csl(TI), CdWO4. On the basis of these data, it is proposed to use ZnSe(Te) in the 20-100 keV range at object movement speed up to 10 cm/s, Csl(TI) — 90—500 keV up to 10 cm/s, CdWO4 150 keV at the speeds up to 500 cm/s. В связи с увеличением количества предложении на рынке сцинтилляторов с различными характеристиками, трудно оценить их по влиянию тоИ или иноИ характеристики сцинтиллятора на параметры цифровоИ рентгенографической системы. Поэтому актуален подбор сцинтиллятора для детекторов типа сцинтиллятор-фотодиод (СЦ-ФД) при проектировании и создании рентгенографических систем. Нами предлагается простая методика выбора сцинтилляторов для цифровоИ радиографии, использующих линеИные матрицы детекторов типа СЦ-ФД. Она позволяет на основе амплитудно-временных характеристик сцинтиллятора (временные зависимости высвечивания и послесвечения, световыход) оценивать изменение относительноИ чувствительности радиографическоИ системы в целом при изменении скорости перемещения объекта и энергии ионизирующего излучения. Приводятся амплитудно-временные характеристики сцинтилляторов ZnSe(Te), Csl(TI), CdWO4. На основании этих данных предлагается использовать ZnSe(Te) в диапазоне 20-100 кэВ при скорости объекта не более 10 см/с, Csl(TI) — 90-500 кэВ до 10 см/с, CdWO4 150 кэВ при скорости до 500 см/с. У зв’язку з підвищєною кількістю пропозиціИ на ринку сцинтиляторів з різними характеристиками, важко оцінити їх за впливом тієї чі іншої характеристики сцинтилятору на параметри цифрової рентгенографічної системи. Тому підбір сцинтилятора до детектора типу сцинтилятор-фотодіод (СЦ-ФД) при проектуванні та створенні рент-генографичних систем є актуальним. Нами пропонується проста методика вибору сцинтиляторів до цифрової радіографії, що використовують лініИну матрицю детекторів типу СЦ-ФД. Вона дозволяє на підставі амплітудно-часової характеристики сцинтилятора (часова залежність висвітлення та післясвітіння, світловихід) оцінювати зміну відносної чутливості радіографічної системи у цілому при зміні швидкості переміщення об’єкту та енергії іонізуючого випромінення. Наводяться амплітудно-часові характеристики сцинтиляторів ZnSe(Te), Csl(TI), CdWO4. На підставі цих даних пропонується застосовувати ZnSe(Te) в діапазоні 20-100 кеВ при швидкості об’єкту не більш ніж 10 см/с, Csl(TI) — 90-500 кеВ до 10 см/с, CdWO4 150 кеВ при швидкості до 500 см/с.
issn 1027-5495
url https://nasplib.isofts.kiev.ua/handle/123456789/135258
citation_txt On the choice of scintillators for "scintillator-photodiode" detectors for digital radiography / V.D. Ryzhikov, D.N. Kozin // Functional Materials. — 2004. — Т. 11, № 1. — С. 205-209. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT ryzhikovvd onthechoiceofscintillatorsforscintillatorphotodiodedetectorsfordigitalradiography
AT kozindn onthechoiceofscintillatorsforscintillatorphotodiodedetectorsfordigitalradiography
AT ryzhikovvd vibírscintilâtoradodetektorívtipuscintilâtorfotodíoddocifrovoíradígrafíí
AT kozindn vibírscintilâtoradodetektorívtipuscintilâtorfotodíoddocifrovoíradígrafíí
first_indexed 2025-12-07T21:01:45Z
last_indexed 2025-12-07T21:01:45Z
_version_ 1850884809659777024