Light collection peculiarities in X-ray scintillation detectors

The X-ray energy that can be detected using Nal(TI) scintillators is rather low (5 to 60 keV), thus, it is especially important to achieve the maximum light collection. In this work, the factors favoring enhanced light collection in such detectors have been studied. To that end, the light collection...

Full description

Saved in:
Bibliographic Details
Published in:Functional Materials
Date:2008
Main Authors: Gorbacheva, T.E., Tarasov, V.A., Vidayj, Yu.T., Ananenko, A.A., Gavrylyuk, V.P.
Format: Article
Language:English
Published: НТК «Інститут монокристалів» НАН України 2008
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/137221
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Light collection peculiarities in X-ray scintillation detectors / T.E. Gorbacheva, V.A. Tarasov, Yu.T. Vidayj, A.A. Ananenko, V.P. Gavrylyuk // Functional Materials. — 2008. — Т. 15, № 1. — С. 97-101. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-137221
record_format dspace
spelling Gorbacheva, T.E.
Tarasov, V.A.
Vidayj, Yu.T.
Ananenko, A.A.
Gavrylyuk, V.P.
2018-06-17T09:04:17Z
2018-06-17T09:04:17Z
2008
Light collection peculiarities in X-ray scintillation detectors / T.E. Gorbacheva, V.A. Tarasov, Yu.T. Vidayj, A.A. Ananenko, V.P. Gavrylyuk // Functional Materials. — 2008. — Т. 15, № 1. — С. 97-101. — Бібліогр.: 4 назв. — англ.
1027-5495
https://nasplib.isofts.kiev.ua/handle/123456789/137221
The X-ray energy that can be detected using Nal(TI) scintillators is rather low (5 to 60 keV), thus, it is especially important to achieve the maximum light collection. In this work, the factors favoring enhanced light collection in such detectors have been studied. To that end, the light collection process has been simulated and studied in experiments using various technology and design features of the detector manufacturing. The experimental results have been shown to confirm the calculation data obtained using the simulation.
en
НТК «Інститут монокристалів» НАН України
Functional Materials
Modeling and simulation
Light collection peculiarities in X-ray scintillation detectors
Особливості світлозбору у детекторах рентгенівського випромінювання
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Light collection peculiarities in X-ray scintillation detectors
spellingShingle Light collection peculiarities in X-ray scintillation detectors
Gorbacheva, T.E.
Tarasov, V.A.
Vidayj, Yu.T.
Ananenko, A.A.
Gavrylyuk, V.P.
Modeling and simulation
title_short Light collection peculiarities in X-ray scintillation detectors
title_full Light collection peculiarities in X-ray scintillation detectors
title_fullStr Light collection peculiarities in X-ray scintillation detectors
title_full_unstemmed Light collection peculiarities in X-ray scintillation detectors
title_sort light collection peculiarities in x-ray scintillation detectors
author Gorbacheva, T.E.
Tarasov, V.A.
Vidayj, Yu.T.
Ananenko, A.A.
Gavrylyuk, V.P.
author_facet Gorbacheva, T.E.
Tarasov, V.A.
Vidayj, Yu.T.
Ananenko, A.A.
Gavrylyuk, V.P.
topic Modeling and simulation
topic_facet Modeling and simulation
publishDate 2008
language English
container_title Functional Materials
publisher НТК «Інститут монокристалів» НАН України
format Article
title_alt Особливості світлозбору у детекторах рентгенівського випромінювання
description The X-ray energy that can be detected using Nal(TI) scintillators is rather low (5 to 60 keV), thus, it is especially important to achieve the maximum light collection. In this work, the factors favoring enhanced light collection in such detectors have been studied. To that end, the light collection process has been simulated and studied in experiments using various technology and design features of the detector manufacturing. The experimental results have been shown to confirm the calculation data obtained using the simulation.
issn 1027-5495
url https://nasplib.isofts.kiev.ua/handle/123456789/137221
citation_txt Light collection peculiarities in X-ray scintillation detectors / T.E. Gorbacheva, V.A. Tarasov, Yu.T. Vidayj, A.A. Ananenko, V.P. Gavrylyuk // Functional Materials. — 2008. — Т. 15, № 1. — С. 97-101. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT gorbachevate lightcollectionpeculiaritiesinxrayscintillationdetectors
AT tarasovva lightcollectionpeculiaritiesinxrayscintillationdetectors
AT vidayjyut lightcollectionpeculiaritiesinxrayscintillationdetectors
AT ananenkoaa lightcollectionpeculiaritiesinxrayscintillationdetectors
AT gavrylyukvp lightcollectionpeculiaritiesinxrayscintillationdetectors
AT gorbachevate osoblivostísvítlozboruudetektorahrentgenívsʹkogovipromínûvannâ
AT tarasovva osoblivostísvítlozboruudetektorahrentgenívsʹkogovipromínûvannâ
AT vidayjyut osoblivostísvítlozboruudetektorahrentgenívsʹkogovipromínûvannâ
AT ananenkoaa osoblivostísvítlozboruudetektorahrentgenívsʹkogovipromínûvannâ
AT gavrylyukvp osoblivostísvítlozboruudetektorahrentgenívsʹkogovipromínûvannâ
first_indexed 2025-12-07T17:17:37Z
last_indexed 2025-12-07T17:17:37Z
_version_ 1850870708616298496