Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator
Theoretical investigations have made it possible to derive an algorithm of 3-dimensional tomographic reconstruction for a cylindrical gamma-ray camera with a pin-hole type collimator. The optimum number of the pin-hole collimators has been found providing the image formation on the whole surface of...
Gespeichert in:
| Veröffentlicht in: | Functional Materials |
|---|---|
| Datum: | 2009 |
| Hauptverfasser: | , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
НТК «Інститут монокристалів» НАН України
2009
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/137739 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator // A.V. Dyomin, A.P. Skibin // Functional Materials. — 2009. — Т. 16, № 2. — С. 206-210. — Бібліогр.: 11 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-137739 |
|---|---|
| record_format |
dspace |
| spelling |
Dyomin, A.V. Skibin, A.P. 2018-06-17T15:45:49Z 2018-06-17T15:45:49Z 2009 Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator // A.V. Dyomin, A.P. Skibin // Functional Materials. — 2009. — Т. 16, № 2. — С. 206-210. — Бібліогр.: 11 назв. — англ. 1027-5495 https://nasplib.isofts.kiev.ua/handle/123456789/137739 Theoretical investigations have made it possible to derive an algorithm of 3-dimensional tomographic reconstruction for a cylindrical gamma-ray camera with a pin-hole type collimator. The optimum number of the pin-hole collimators has been found providing the image formation on the whole surface of the cylindrical detector. Formulas have been derived correlating the tomographic projections in the planar and cylindrical geometry. A precision tomographic system has been designed and constructed basing on an annular scintillation detector and a Multi Pin-hole collimator. The space resolution of the system amounts 1 mm. Виконані теоретичні дослідження дозволили створити алгоритм тривимірної томографічної реконструкції для циліндричної гамма-камери з коліматором типу pin-hole. Визначено оптимальну кількість pin-hole коліматорів для формування зображення на всій поверхні циліндричного детектора. Виведено формули, які пов'язують томографічні проекції у площинній та циліндричній геометрії. Спроектовано та виготовлено прецизійну томографічну систему на основі кільцевого сцинтиляційного детектора та multi-pin-hole коліматора. Просторове розріmення прецизійної системи становить 1 мм. Проведенные теоретические исследования позволили создать алгоритм трёхмерной томографической реконструкции для цилиндрической гамма-камеры с коллиматором типа Pin-hole. Найдено оптимальное количество pin-hole коллиматоров для формирования изображения на всей плоскости цилиндрического детектора. Выведены формулы, связывающие томографические проекции в плоской и цилиндрической геометрии. Спроектирована и изготовлена прецизионная томографическая система на базе кольцевого сцинтилляционного детектора и Multi Pin-hole коллиматора. Пространственное разрешение прецизионной системы составляет 1 мм. en НТК «Інститут монокристалів» НАН України Functional Materials Technology Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator Прецизійна томографічна система на основі кільцевого сцинтиляційного детектора та multi-pin-hole коліматора Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator |
| spellingShingle |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator Dyomin, A.V. Skibin, A.P. Technology |
| title_short |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator |
| title_full |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator |
| title_fullStr |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator |
| title_full_unstemmed |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator |
| title_sort |
precision tomoghaphic system based on annular scintillation detector and multi pin-hole collimator |
| author |
Dyomin, A.V. Skibin, A.P. |
| author_facet |
Dyomin, A.V. Skibin, A.P. |
| topic |
Technology |
| topic_facet |
Technology |
| publishDate |
2009 |
| language |
English |
| container_title |
Functional Materials |
| publisher |
НТК «Інститут монокристалів» НАН України |
| format |
Article |
| title_alt |
Прецизійна томографічна система на основі кільцевого сцинтиляційного детектора та multi-pin-hole коліматора |
| description |
Theoretical investigations have made it possible to derive an algorithm of 3-dimensional tomographic reconstruction for a cylindrical gamma-ray camera with a pin-hole type collimator. The optimum number of the pin-hole collimators has been found providing the image formation on the whole surface of the cylindrical detector. Formulas have been derived correlating the tomographic projections in the planar and cylindrical geometry. A precision tomographic system has been designed and constructed basing on an annular scintillation detector and a Multi Pin-hole collimator. The space resolution of the system amounts 1 mm.
Виконані теоретичні дослідження дозволили створити алгоритм тривимірної томографічної реконструкції для циліндричної гамма-камери з коліматором типу pin-hole. Визначено оптимальну кількість pin-hole коліматорів для формування зображення на всій поверхні циліндричного детектора. Виведено формули, які пов'язують томографічні проекції у площинній та циліндричній геометрії. Спроектовано та виготовлено прецизійну томографічну систему на основі кільцевого сцинтиляційного детектора та multi-pin-hole коліматора. Просторове розріmення прецизійної системи становить 1 мм.
Проведенные теоретические исследования позволили создать алгоритм трёхмерной томографической реконструкции для цилиндрической гамма-камеры с коллиматором типа Pin-hole. Найдено оптимальное количество pin-hole коллиматоров для формирования изображения на всей плоскости цилиндрического детектора. Выведены формулы, связывающие томографические проекции в плоской и цилиндрической геометрии. Спроектирована и изготовлена прецизионная томографическая система на базе кольцевого сцинтилляционного детектора и Multi Pin-hole коллиматора. Пространственное разрешение прецизионной системы составляет 1 мм.
|
| issn |
1027-5495 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/137739 |
| citation_txt |
Precision tomoghaphic system based on annular scintillation detector and Multi Pin-hole collimator // A.V. Dyomin, A.P. Skibin // Functional Materials. — 2009. — Т. 16, № 2. — С. 206-210. — Бібліогр.: 11 назв. — англ. |
| work_keys_str_mv |
AT dyominav precisiontomoghaphicsystembasedonannularscintillationdetectorandmultipinholecollimator AT skibinap precisiontomoghaphicsystembasedonannularscintillationdetectorandmultipinholecollimator AT dyominav precizíinatomografíčnasistemanaosnovíkílʹcevogoscintilâcíinogodetektoratamultipinholekolímatora AT skibinap precizíinatomografíčnasistemanaosnovíkílʹcevogoscintilâcíinogodetektoratamultipinholekolímatora |
| first_indexed |
2025-12-07T19:01:29Z |
| last_indexed |
2025-12-07T19:01:29Z |
| _version_ |
1850877242918305792 |