Portable radiation monitoring system on the base of CdWO₄ scintillator
A portable high-sensitivity monitor for the detection of radioactive materials is developed and manufactured on the base of CdW0₄ scintillation crystal. The monitor has an independent power supply which provides continuous operation at least during 120 hours. Розроблено і виготовлено портативний вис...
Gespeichert in:
| Veröffentlicht in: | Functional Materials |
|---|---|
| Datum: | 2009 |
| Hauptverfasser: | , , , , , , , , , , , , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
НТК «Інститут монокристалів» НАН України
2009
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/138931 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Portable radiation monitoring system on the base of CdWO₄ scintillator // M.B. Kosmyna, B.P. Nazarenko, V.M. Puzikov, A.N. Shekhovtsov, B.V. Grinyov, Yu.A. Borodenko, Ye.M. Selegenev, V.D. Ryzhikov, L.A. Piven, V.A. Tarasov, Yu.S. Kozmin, V.V. Belogub, A.V. Didenko // Functional Materials. — 2009. — Т. 16, № 4. — С. 505-507. — Бібліогр.: 5 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-138931 |
|---|---|
| record_format |
dspace |
| spelling |
Kosmyna, M.B. Nazarenko, B.P. Puzikov, V.M. Shekhovtsov, A.N. Grinyov, B.V. Borodenko, Yu.A. Selegenev, Ye.M. Ryzhikov, V.D. Piven, L.A. Tarasov, V.A. Kozmin, Yu.S. Belogub, V.V. Didenko, A.V. 2018-06-19T17:19:41Z 2018-06-19T17:19:41Z 2009 Portable radiation monitoring system on the base of CdWO₄ scintillator // M.B. Kosmyna, B.P. Nazarenko, V.M. Puzikov, A.N. Shekhovtsov, B.V. Grinyov, Yu.A. Borodenko, Ye.M. Selegenev, V.D. Ryzhikov, L.A. Piven, V.A. Tarasov, Yu.S. Kozmin, V.V. Belogub, A.V. Didenko // Functional Materials. — 2009. — Т. 16, № 4. — С. 505-507. — Бібліогр.: 5 назв. — англ. 1027-5495 https://nasplib.isofts.kiev.ua/handle/123456789/138931 A portable high-sensitivity monitor for the detection of radioactive materials is developed and manufactured on the base of CdW0₄ scintillation crystal. The monitor has an independent power supply which provides continuous operation at least during 120 hours. Розроблено і виготовлено портативний високочутливий портал для виявлення радіоактивних матеріалів на базі сцинтиляційного кристала CdW0₄. Портал має власний блок живлення, який забезпечує його безперервну роботу протягом 120 годин. Разработан и изготовлен портативный высокочувствительный портал для обнаружения радиоактивных материалов на базе сцинтилляционного кристалла CdWO₄. Портал оснащен собственным источником питания, который обеспечивает его непрерывную работу в течение 120 часов. en НТК «Інститут монокристалів» НАН України Functional Materials Technology Portable radiation monitoring system on the base of CdWO₄ scintillator Портативний радіаційний монітор на основі сцинтилятора CdW0₄ Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
Portable radiation monitoring system on the base of CdWO₄ scintillator |
| spellingShingle |
Portable radiation monitoring system on the base of CdWO₄ scintillator Kosmyna, M.B. Nazarenko, B.P. Puzikov, V.M. Shekhovtsov, A.N. Grinyov, B.V. Borodenko, Yu.A. Selegenev, Ye.M. Ryzhikov, V.D. Piven, L.A. Tarasov, V.A. Kozmin, Yu.S. Belogub, V.V. Didenko, A.V. Technology |
| title_short |
Portable radiation monitoring system on the base of CdWO₄ scintillator |
| title_full |
Portable radiation monitoring system on the base of CdWO₄ scintillator |
| title_fullStr |
Portable radiation monitoring system on the base of CdWO₄ scintillator |
| title_full_unstemmed |
Portable radiation monitoring system on the base of CdWO₄ scintillator |
| title_sort |
portable radiation monitoring system on the base of cdwo₄ scintillator |
| author |
Kosmyna, M.B. Nazarenko, B.P. Puzikov, V.M. Shekhovtsov, A.N. Grinyov, B.V. Borodenko, Yu.A. Selegenev, Ye.M. Ryzhikov, V.D. Piven, L.A. Tarasov, V.A. Kozmin, Yu.S. Belogub, V.V. Didenko, A.V. |
| author_facet |
Kosmyna, M.B. Nazarenko, B.P. Puzikov, V.M. Shekhovtsov, A.N. Grinyov, B.V. Borodenko, Yu.A. Selegenev, Ye.M. Ryzhikov, V.D. Piven, L.A. Tarasov, V.A. Kozmin, Yu.S. Belogub, V.V. Didenko, A.V. |
| topic |
Technology |
| topic_facet |
Technology |
| publishDate |
2009 |
| language |
English |
| container_title |
Functional Materials |
| publisher |
НТК «Інститут монокристалів» НАН України |
| format |
Article |
| title_alt |
Портативний радіаційний монітор на основі сцинтилятора CdW0₄ |
| description |
A portable high-sensitivity monitor for the detection of radioactive materials is developed and manufactured on the base of CdW0₄ scintillation crystal. The monitor has an independent power supply which provides continuous operation at least during 120 hours.
Розроблено і виготовлено портативний високочутливий портал для виявлення радіоактивних матеріалів на базі сцинтиляційного кристала CdW0₄. Портал має власний блок живлення, який забезпечує його безперервну роботу протягом 120 годин.
Разработан и изготовлен портативный высокочувствительный портал для обнаружения радиоактивных материалов на базе сцинтилляционного кристалла CdWO₄. Портал оснащен собственным источником питания, который обеспечивает его непрерывную работу в течение 120 часов.
|
| issn |
1027-5495 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/138931 |
| citation_txt |
Portable radiation monitoring system on the base of CdWO₄ scintillator // M.B. Kosmyna, B.P. Nazarenko, V.M. Puzikov, A.N. Shekhovtsov, B.V. Grinyov, Yu.A. Borodenko, Ye.M. Selegenev, V.D. Ryzhikov, L.A. Piven, V.A. Tarasov, Yu.S. Kozmin, V.V. Belogub, A.V. Didenko // Functional Materials. — 2009. — Т. 16, № 4. — С. 505-507. — Бібліогр.: 5 назв. — англ. |
| work_keys_str_mv |
AT kosmynamb portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT nazarenkobp portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT puzikovvm portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT shekhovtsovan portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT grinyovbv portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT borodenkoyua portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT selegenevyem portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT ryzhikovvd portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT pivenla portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT tarasovva portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT kozminyus portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT belogubvv portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT didenkoav portableradiationmonitoringsystemonthebaseofcdwo4scintillator AT kosmynamb portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT nazarenkobp portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT puzikovvm portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT shekhovtsovan portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT grinyovbv portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT borodenkoyua portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT selegenevyem portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT ryzhikovvd portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT pivenla portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT tarasovva portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT kozminyus portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT belogubvv portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 AT didenkoav portativniiradíacíiniimonítornaosnovíscintilâtoracdw04 |
| first_indexed |
2025-12-07T17:01:16Z |
| last_indexed |
2025-12-07T17:01:16Z |
| _version_ |
1850869680028254208 |