Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes

A small-sized gamma-detection block of scintillator-photodiodetem is reported. The block operates in the 0.05-3.0 meV energy range and the dose rate range from 10⁻⁶ to 10³ R/h and more. The detection block operates in a combined counting-current mode with spectrometry functions. Transition from the...

Full description

Saved in:
Bibliographic Details
Published in:Functional Materials
Date:2004
Main Authors: Nekrasov, V.V., Belogub, V.V., Selegenev, E.M., Grynyov, B.V., Borodenko, Yu.A.
Format: Article
Language:English
Published: НТК «Інститут монокристалів» НАН України 2004
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/139306
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes / V.V. Nekrasov, V.V. Belogub , E.M. Selegenev, B.V. Grynyov, Yu.A. Borodenko // Functional Materials. — 2004. — Т. 11, № 2. — С. 420-425. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-139306
record_format dspace
spelling Nekrasov, V.V.
Belogub, V.V.
Selegenev, E.M.
Grynyov, B.V.
Borodenko, Yu.A.
2018-06-20T04:57:03Z
2018-06-20T04:57:03Z
2004
Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes / V.V. Nekrasov, V.V. Belogub , E.M. Selegenev, B.V. Grynyov, Yu.A. Borodenko // Functional Materials. — 2004. — Т. 11, № 2. — С. 420-425. — Бібліогр.: 4 назв. — англ.
1027-5495
https://nasplib.isofts.kiev.ua/handle/123456789/139306
A small-sized gamma-detection block of scintillator-photodiodetem is reported. The block operates in the 0.05-3.0 meV energy range and the dose rate range from 10⁻⁶ to 10³ R/h and more. The detection block operates in a combined counting-current mode with spectrometry functions. Transition from the counting mode to the current mode and back is carried out automatically. The detection block is designed for use in azimuthal detectin g complexes of surveyor robots, in multifunctional dosimeters, direction-finding dosimeters, etc.
Разработан малогабаритный блок детектирования у -излучения системы сцинтиллятор-фотодиод, работающий в диапазоне энергий 0,05-3,0 меВ и диапазоне мощностей доз от 10⁻⁶ до 10³ Р/ч и более. Блок детектирования имеет совмещенный счетно-токовый режим с функцией спектрометрии. Переход со счетного режима на токовый и обратно происходит автоматически. Блок детектирования предназначен для использования в азимутально-обнаружительном комплексе робота-разведчика, многофункциональном дозиметре-пеленгаторе и др.
Розроблено малогабаритний блок детектування у-випромінювання системи сцинтилятор-фотодіод, що працює у діапазоні енергій 0,05-3,0 MеВ і діапазоні потужностей доз від 10⁻⁶ до 10³ і більш Р/год. Блок детектування має суміщений рахунково-струмовий режим з функцією спектрометрії. Перехід з рахункового режиму на струмовий і назад проходить автоматично. Блок детектування призначено для використання у азимутально-виявляючому комплексі робота-розвідник, багатофункціональному дозиметрі, дозиметрі-пеленгаторі та ін.
en
НТК «Інститут монокристалів» НАН України
Functional Materials
News of technology
Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
Розробка блока детектування системи сцинтилятор-фотодіод сполученого режиму роботи (лічильно-токовий) для азимутально-виявного комплексу
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
spellingShingle Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
Nekrasov, V.V.
Belogub, V.V.
Selegenev, E.M.
Grynyov, B.V.
Borodenko, Yu.A.
News of technology
title_short Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
title_full Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
title_fullStr Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
title_full_unstemmed Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
title_sort development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes
author Nekrasov, V.V.
Belogub, V.V.
Selegenev, E.M.
Grynyov, B.V.
Borodenko, Yu.A.
author_facet Nekrasov, V.V.
Belogub, V.V.
Selegenev, E.M.
Grynyov, B.V.
Borodenko, Yu.A.
topic News of technology
topic_facet News of technology
publishDate 2004
language English
container_title Functional Materials
publisher НТК «Інститут монокристалів» НАН України
format Article
title_alt Розробка блока детектування системи сцинтилятор-фотодіод сполученого режиму роботи (лічильно-токовий) для азимутально-виявного комплексу
description A small-sized gamma-detection block of scintillator-photodiodetem is reported. The block operates in the 0.05-3.0 meV energy range and the dose rate range from 10⁻⁶ to 10³ R/h and more. The detection block operates in a combined counting-current mode with spectrometry functions. Transition from the counting mode to the current mode and back is carried out automatically. The detection block is designed for use in azimuthal detectin g complexes of surveyor robots, in multifunctional dosimeters, direction-finding dosimeters, etc. Разработан малогабаритный блок детектирования у -излучения системы сцинтиллятор-фотодиод, работающий в диапазоне энергий 0,05-3,0 меВ и диапазоне мощностей доз от 10⁻⁶ до 10³ Р/ч и более. Блок детектирования имеет совмещенный счетно-токовый режим с функцией спектрометрии. Переход со счетного режима на токовый и обратно происходит автоматически. Блок детектирования предназначен для использования в азимутально-обнаружительном комплексе робота-разведчика, многофункциональном дозиметре-пеленгаторе и др. Розроблено малогабаритний блок детектування у-випромінювання системи сцинтилятор-фотодіод, що працює у діапазоні енергій 0,05-3,0 MеВ і діапазоні потужностей доз від 10⁻⁶ до 10³ і більш Р/год. Блок детектування має суміщений рахунково-струмовий режим з функцією спектрометрії. Перехід з рахункового режиму на струмовий і назад проходить автоматично. Блок детектування призначено для використання у азимутально-виявляючому комплексі робота-розвідник, багатофункціональному дозиметрі, дозиметрі-пеленгаторі та ін.
issn 1027-5495
url https://nasplib.isofts.kiev.ua/handle/123456789/139306
fulltext
citation_txt Development of a detection block of a combined mode scintillator-photodiode system (counting-current) for azimuthal detecting complexes / V.V. Nekrasov, V.V. Belogub , E.M. Selegenev, B.V. Grynyov, Yu.A. Borodenko // Functional Materials. — 2004. — Т. 11, № 2. — С. 420-425. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT nekrasovvv developmentofadetectionblockofacombinedmodescintillatorphotodiodesystemcountingcurrentforazimuthaldetectingcomplexes
AT belogubvv developmentofadetectionblockofacombinedmodescintillatorphotodiodesystemcountingcurrentforazimuthaldetectingcomplexes
AT selegenevem developmentofadetectionblockofacombinedmodescintillatorphotodiodesystemcountingcurrentforazimuthaldetectingcomplexes
AT grynyovbv developmentofadetectionblockofacombinedmodescintillatorphotodiodesystemcountingcurrentforazimuthaldetectingcomplexes
AT borodenkoyua developmentofadetectionblockofacombinedmodescintillatorphotodiodesystemcountingcurrentforazimuthaldetectingcomplexes
AT nekrasovvv rozrobkablokadetektuvannâsistemiscintilâtorfotodíodspolučenogorežimurobotilíčilʹnotokoviidlâazimutalʹnoviâvnogokompleksu
AT belogubvv rozrobkablokadetektuvannâsistemiscintilâtorfotodíodspolučenogorežimurobotilíčilʹnotokoviidlâazimutalʹnoviâvnogokompleksu
AT selegenevem rozrobkablokadetektuvannâsistemiscintilâtorfotodíodspolučenogorežimurobotilíčilʹnotokoviidlâazimutalʹnoviâvnogokompleksu
AT grynyovbv rozrobkablokadetektuvannâsistemiscintilâtorfotodíodspolučenogorežimurobotilíčilʹnotokoviidlâazimutalʹnoviâvnogokompleksu
AT borodenkoyua rozrobkablokadetektuvannâsistemiscintilâtorfotodíodspolučenogorežimurobotilíčilʹnotokoviidlâazimutalʹnoviâvnogokompleksu
first_indexed 2025-11-26T14:28:12Z
last_indexed 2025-11-26T14:28:12Z
_version_ 1850624557917929472