Problem with output relays used in microprocessor-based protection devices: what to do?

It is the author’s second publication on nonconformance of parameters of subminiature output relays used in microprocessor-based protective devices to actual operation conditions and standards. The article suggests adjustment of the standards and presents specific engineering solutions to this probl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Електротехніка і електромеханіка
Datum:2007
1. Verfasser: Gurevich, V.I.
Format: Artikel
Sprache:English
Veröffentlicht: Інститут технічних проблем магнетизму НАН України 2007
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/142934
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Problem with output relays used in microprocessor-based protection devices: what to do? / V.I. Gurevich // Електротехніка і електромеханіка. — 2007. — № 6. — С. 24-29. — Бібліогр.: 3 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-142934
record_format dspace
spelling Gurevich, V.I.
2018-10-19T19:36:05Z
2018-10-19T19:36:05Z
2007
Problem with output relays used in microprocessor-based protection devices: what to do? / V.I. Gurevich // Електротехніка і електромеханіка. — 2007. — № 6. — С. 24-29. — Бібліогр.: 3 назв. — англ.
2074-272X
https://nasplib.isofts.kiev.ua/handle/123456789/142934
621.316+004.315
It is the author’s second publication on nonconformance of parameters of subminiature output relays used in microprocessor-based protective devices to actual operation conditions and standards. The article suggests adjustment of the standards and presents specific engineering solutions to this problem.
Друга публікація автора на тему про невідповідність параметрів субмініатюрних вихідних реле мікропроцесорних пристроїв релейного захисту реальним умовам експлуатації і стандартам, що діють. У даній статті пропонуються заходи по уточненню стандартів, а також приводяться конкретні технічні рішення цієї проблеми.
Вторая публикация автора на тему о несоответствии параметров субминиатюрных выходных реле микропроцессорных устройств релейной защиты реальным условиям эксплуатации и действующим стандартам. В данной статье предлагаются меры по уточнению стандартов, а также приводятся конкретные технические решения этой проблемы.
en
Інститут технічних проблем магнетизму НАН України
Електротехніка і електромеханіка
Електричні машини та апарати
Problem with output relays used in microprocessor-based protection devices: what to do?
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Problem with output relays used in microprocessor-based protection devices: what to do?
spellingShingle Problem with output relays used in microprocessor-based protection devices: what to do?
Gurevich, V.I.
Електричні машини та апарати
title_short Problem with output relays used in microprocessor-based protection devices: what to do?
title_full Problem with output relays used in microprocessor-based protection devices: what to do?
title_fullStr Problem with output relays used in microprocessor-based protection devices: what to do?
title_full_unstemmed Problem with output relays used in microprocessor-based protection devices: what to do?
title_sort problem with output relays used in microprocessor-based protection devices: what to do?
author Gurevich, V.I.
author_facet Gurevich, V.I.
topic Електричні машини та апарати
topic_facet Електричні машини та апарати
publishDate 2007
language English
container_title Електротехніка і електромеханіка
publisher Інститут технічних проблем магнетизму НАН України
format Article
description It is the author’s second publication on nonconformance of parameters of subminiature output relays used in microprocessor-based protective devices to actual operation conditions and standards. The article suggests adjustment of the standards and presents specific engineering solutions to this problem. Друга публікація автора на тему про невідповідність параметрів субмініатюрних вихідних реле мікропроцесорних пристроїв релейного захисту реальним умовам експлуатації і стандартам, що діють. У даній статті пропонуються заходи по уточненню стандартів, а також приводяться конкретні технічні рішення цієї проблеми. Вторая публикация автора на тему о несоответствии параметров субминиатюрных выходных реле микропроцессорных устройств релейной защиты реальным условиям эксплуатации и действующим стандартам. В данной статье предлагаются меры по уточнению стандартов, а также приводятся конкретные технические решения этой проблемы.
issn 2074-272X
url https://nasplib.isofts.kiev.ua/handle/123456789/142934
citation_txt Problem with output relays used in microprocessor-based protection devices: what to do? / V.I. Gurevich // Електротехніка і електромеханіка. — 2007. — № 6. — С. 24-29. — Бібліогр.: 3 назв. — англ.
work_keys_str_mv AT gurevichvi problemwithoutputrelaysusedinmicroprocessorbasedprotectiondeviceswhattodo
first_indexed 2025-11-30T23:09:40Z
last_indexed 2025-11-30T23:09:40Z
_version_ 1850858761470607360