A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches

This article presents the powers control of a variable speed wind turbine based on a doubly fed induction generator (DFIG) because
 of their advantages in terms of economy and control. The considered system consists of a DFIG whose stator is connected directly to
 the electrical netw...

Full description

Saved in:
Bibliographic Details
Published in:Електротехніка і електромеханіка
Date:2018
Main Authors: Benkahla, M., Taleb, R., Boudjema, Z.
Format: Article
Language:English
Published: Інститут технічних проблем магнетизму НАН України 2018
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/147950
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches / M. Benkahla, R. Taleb, Z. Boudjema // Електротехніка і електромеханіка. — 2018. — № 4. — С. 11-19. — Бібліогр.: 34 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862742393181175808
author Benkahla, M.
Taleb, R.
Boudjema, Z.
author_facet Benkahla, M.
Taleb, R.
Boudjema, Z.
citation_txt A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches / M. Benkahla, R. Taleb, Z. Boudjema // Електротехніка і електромеханіка. — 2018. — № 4. — С. 11-19. — Бібліогр.: 34 назв. — англ.
collection DSpace DC
container_title Електротехніка і електромеханіка
description This article presents the powers control of a variable speed wind turbine based on a doubly fed induction generator (DFIG) because
 of their advantages in terms of economy and control. The considered system consists of a DFIG whose stator is connected directly to
 the electrical network and its rotor is supplied by a 19-level inverter with less number of switches for minimize the harmonics
 absorbed by the DFIG, reducing switching frequency, high power electronic applications because of their ability to generate a very
 good quality of waveforms, and their low voltage stress across the power devices. In order to control independently active and reactive
 powers provided by the stator side of the DFIG to the grid and ensure high performance and a better execution, three types of robust
 controllers have been studied and compared in terms of power reference tracking, response to sudden speed variations, sensitivity to
 perturbations and robustness against machine parameters variations В статье описывается управление мощностью ветряной турбины переменной скорости на основе асинхронного
 генератора двойного питания ввиду их преимуществ с точки зрения экономичности и управления. Рассматриваемая
 система состоит из асинхронного генератора двойного питания, статор которого подключен непосредственно к
 электрической сети, а его ротор питается от 19-уровневого инвертора с меньшим количеством коммутаторов для
 минимизации гармоник, поглощаемых генератором, уменьшая частоту переключения, и устройств силовой электроники
 вследствие их способности генерировать высокое качество сигналов и низкого уровня напряжения на них. Чтобы
 независимо управлять активной и реактивной мощностью, подаваемой стороной статора указанного генератора в сеть,
 и обеспечивать высокую производительность и лучшее конструктивное исполнение, изучены и сопоставлены три типа
 робастных контроллеров с точки зрения отслеживания мощности, реакции на внезапное изменение скорости,
 чувствительности к возмущениям и устойчивости к изменениям параметров машины
first_indexed 2025-12-07T20:24:47Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-147950
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 2074-272X
language English
last_indexed 2025-12-07T20:24:47Z
publishDate 2018
publisher Інститут технічних проблем магнетизму НАН України
record_format dspace
spelling Benkahla, M.
Taleb, R.
Boudjema, Z.
2019-02-16T12:10:36Z
2019-02-16T12:10:36Z
2018
A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches / M. Benkahla, R. Taleb, Z. Boudjema // Електротехніка і електромеханіка. — 2018. — № 4. — С. 11-19. — Бібліогр.: 34 назв. — англ.
2074-272X
DOI: https://doi.org/10.20998/2074-272X.2018.4.02
https://nasplib.isofts.kiev.ua/handle/123456789/147950
621.3.07
This article presents the powers control of a variable speed wind turbine based on a doubly fed induction generator (DFIG) because
 of their advantages in terms of economy and control. The considered system consists of a DFIG whose stator is connected directly to
 the electrical network and its rotor is supplied by a 19-level inverter with less number of switches for minimize the harmonics
 absorbed by the DFIG, reducing switching frequency, high power electronic applications because of their ability to generate a very
 good quality of waveforms, and their low voltage stress across the power devices. In order to control independently active and reactive
 powers provided by the stator side of the DFIG to the grid and ensure high performance and a better execution, three types of robust
 controllers have been studied and compared in terms of power reference tracking, response to sudden speed variations, sensitivity to
 perturbations and robustness against machine parameters variations
В статье описывается управление мощностью ветряной турбины переменной скорости на основе асинхронного
 генератора двойного питания ввиду их преимуществ с точки зрения экономичности и управления. Рассматриваемая
 система состоит из асинхронного генератора двойного питания, статор которого подключен непосредственно к
 электрической сети, а его ротор питается от 19-уровневого инвертора с меньшим количеством коммутаторов для
 минимизации гармоник, поглощаемых генератором, уменьшая частоту переключения, и устройств силовой электроники
 вследствие их способности генерировать высокое качество сигналов и низкого уровня напряжения на них. Чтобы
 независимо управлять активной и реактивной мощностью, подаваемой стороной статора указанного генератора в сеть,
 и обеспечивать высокую производительность и лучшее конструктивное исполнение, изучены и сопоставлены три типа
 робастных контроллеров с точки зрения отслеживания мощности, реакции на внезапное изменение скорости,
 чувствительности к возмущениям и устойчивости к изменениям параметров машины
en
Інститут технічних проблем магнетизму НАН України
Електротехніка і електромеханіка
Електротехнічні комплекси та системи. Силова електроніка
A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
Article
published earlier
spellingShingle A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
Benkahla, M.
Taleb, R.
Boudjema, Z.
Електротехнічні комплекси та системи. Силова електроніка
title A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
title_full A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
title_fullStr A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
title_full_unstemmed A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
title_short A new robust control using adaptive fuzzy sliding mode control for a DFIG supplied by a 19-level inverter with less number of switches
title_sort new robust control using adaptive fuzzy sliding mode control for a dfig supplied by a 19-level inverter with less number of switches
topic Електротехнічні комплекси та системи. Силова електроніка
topic_facet Електротехнічні комплекси та системи. Силова електроніка
url https://nasplib.isofts.kiev.ua/handle/123456789/147950
work_keys_str_mv AT benkahlam anewrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches
AT talebr anewrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches
AT boudjemaz anewrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches
AT benkahlam newrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches
AT talebr newrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches
AT boudjemaz newrobustcontrolusingadaptivefuzzyslidingmodecontrolforadfigsuppliedbya19levelinverterwithlessnumberofswitches