Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery

Eighty-eight patients suffering from temporal lobe epilepsy (TLE) underwent epilepsy-related
 surgery monitored by preoperative long-term video EEG (VEEG) and intraoperative ECoG.
 The patterns, location, and spatial distribution of epileptiform discharges recorded by VEEG
 a...

Full description

Saved in:
Bibliographic Details
Published in:Нейрофизиология
Date:2015
Main Authors: Xiang, J., Jiang, Yu.
Format: Article
Language:English
Published: Інститут фізіології ім. О.О. Богомольця НАН України 2015
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/148185
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery / J. Xiang, Yu. Jiang // Нейрофизиология. — 2015. — Т. 47, № 2. — С. 188-193. — Бібліогр.: 19 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862656944811016192
author Xiang, J.
Jiang, Yu.
author_facet Xiang, J.
Jiang, Yu.
citation_txt Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery / J. Xiang, Yu. Jiang // Нейрофизиология. — 2015. — Т. 47, № 2. — С. 188-193. — Бібліогр.: 19 назв. — англ.
collection DSpace DC
container_title Нейрофизиология
description Eighty-eight patients suffering from temporal lobe epilepsy (TLE) underwent epilepsy-related
 surgery monitored by preoperative long-term video EEG (VEEG) and intraoperative ECoG.
 The patterns, location, and spatial distribution of epileptiform discharges recorded by VEEG
 and ECoG were analyzed and compared. In 56 patients, frequent focal epileptiform discharges
 were recorded by VEEG at one side of the temporal lobe and identified in the temporal lobe
 and interior frontal gyrus by ECoG. Epileptiform discharges were recorded by VEEG at both
 sides of the temporal lobe in 20 patients and by all recording electrodes at one side of the
 temporal lobe in 12 patients. In these patients, epileptiform discharges were identified by
 ECoG in the left sylvian gyrus of the temporal lobe and in the inferior and middle frontal
 gyri. Spatial distributions of epileptiform discharges were adequately identified by ECoG in
 52 (59%) patients, with a consistency of > 80% in 24 (27%) patients, and with a consistency
 of 60-80% in 12 (14%) patients, compared with that estimated by VEEG. Patients remained
 seizure-free in 72 (81.8%) cases; their state was improved significantly in 12 (13.6%) cases
 and remained unimproved in 4 (4.5%) cases. Our data suggest that ECoG possesses certain
 advantages over VEEG in accurate localization of the epileptogenic foci and, thus, is important
 for surgical treatment of TLE. У перебігу хірургічного лікування 88 пацієнтів з темпоральною епілепсією (ТЕ) використовували тривалу преопераційну відеоелектроенцефалографію (ВЕЕГ) та інтраоперативну
 електрокортикографію (ЕКоГ). Аналізували патерни, локалізацію і просторовий розподіл епілептиформних розрядів,
 та порівнювали результати використання ВЕЕГ та ЕКоГ.
 Фокальні епілептиформні розряди, що виникали з великою
 частотою, були зареєстровані за допомогою ВЕЕГ у 56 пацієнтів унілатерально в темпоральній частці кори, а ЕКоГ
 дозволяла ідентифікувати такі розряди в темпоральній частці та нижній фронтальній звивині. Подібні розряди відводилися від обох темпоральних часток у 20 пацієнтів та всіма
 електродами унілатерально від однієї темпоральної частки у
 12 пацієнтів. У цих пацієнтів епілептиформні розлади ідентифікувалися за допомогою ЕКоГ у лівій сільвієвій звивині темпоральної частки та в нижній і середній фронтальних
 звивинах. Просторовий розподіл епілептиформних розрядів був адекватно ідентифікований за допомогою ЕКоГ у 52
 (59 %) пацієнтів; співпадіння з даними ВЕЕГ складало більше 80 % у 24 (27 %) пацієнтів і було в межах 60–80 % у 12
 (14 %). Судоми були усунуті у 72 (81.8 %) пацієнтів; стан
 хворих був істотно поліпшений у 12 (13.6 %) випадках і не
 змінювався у чотирьох (4.5 %) випадках. Наші дані свідчать
 про помітні переваги ЕКоГ над ВЕЕГ в аспекті можливості визначення точної локалізації епілептогенних фокусів, і,
 таким чином, її застосування є доцільним при хірургічному
 лікуванні ТЕ.
first_indexed 2025-12-02T05:41:19Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-148185
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 0028-2561
language English
last_indexed 2025-12-02T05:41:19Z
publishDate 2015
publisher Інститут фізіології ім. О.О. Богомольця НАН України
record_format dspace
spelling Xiang, J.
Jiang, Yu.
2019-02-17T16:34:53Z
2019-02-17T16:34:53Z
2015
Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery / J. Xiang, Yu. Jiang // Нейрофизиология. — 2015. — Т. 47, № 2. — С. 188-193. — Бібліогр.: 19 назв. — англ.
0028-2561
https://nasplib.isofts.kiev.ua/handle/123456789/148185
612.014:616.853
Eighty-eight patients suffering from temporal lobe epilepsy (TLE) underwent epilepsy-related
 surgery monitored by preoperative long-term video EEG (VEEG) and intraoperative ECoG.
 The patterns, location, and spatial distribution of epileptiform discharges recorded by VEEG
 and ECoG were analyzed and compared. In 56 patients, frequent focal epileptiform discharges
 were recorded by VEEG at one side of the temporal lobe and identified in the temporal lobe
 and interior frontal gyrus by ECoG. Epileptiform discharges were recorded by VEEG at both
 sides of the temporal lobe in 20 patients and by all recording electrodes at one side of the
 temporal lobe in 12 patients. In these patients, epileptiform discharges were identified by
 ECoG in the left sylvian gyrus of the temporal lobe and in the inferior and middle frontal
 gyri. Spatial distributions of epileptiform discharges were adequately identified by ECoG in
 52 (59%) patients, with a consistency of > 80% in 24 (27%) patients, and with a consistency
 of 60-80% in 12 (14%) patients, compared with that estimated by VEEG. Patients remained
 seizure-free in 72 (81.8%) cases; their state was improved significantly in 12 (13.6%) cases
 and remained unimproved in 4 (4.5%) cases. Our data suggest that ECoG possesses certain
 advantages over VEEG in accurate localization of the epileptogenic foci and, thus, is important
 for surgical treatment of TLE.
У перебігу хірургічного лікування 88 пацієнтів з темпоральною епілепсією (ТЕ) використовували тривалу преопераційну відеоелектроенцефалографію (ВЕЕГ) та інтраоперативну
 електрокортикографію (ЕКоГ). Аналізували патерни, локалізацію і просторовий розподіл епілептиформних розрядів,
 та порівнювали результати використання ВЕЕГ та ЕКоГ.
 Фокальні епілептиформні розряди, що виникали з великою
 частотою, були зареєстровані за допомогою ВЕЕГ у 56 пацієнтів унілатерально в темпоральній частці кори, а ЕКоГ
 дозволяла ідентифікувати такі розряди в темпоральній частці та нижній фронтальній звивині. Подібні розряди відводилися від обох темпоральних часток у 20 пацієнтів та всіма
 електродами унілатерально від однієї темпоральної частки у
 12 пацієнтів. У цих пацієнтів епілептиформні розлади ідентифікувалися за допомогою ЕКоГ у лівій сільвієвій звивині темпоральної частки та в нижній і середній фронтальних
 звивинах. Просторовий розподіл епілептиформних розрядів був адекватно ідентифікований за допомогою ЕКоГ у 52
 (59 %) пацієнтів; співпадіння з даними ВЕЕГ складало більше 80 % у 24 (27 %) пацієнтів і було в межах 60–80 % у 12
 (14 %). Судоми були усунуті у 72 (81.8 %) пацієнтів; стан
 хворих був істотно поліпшений у 12 (13.6 %) випадках і не
 змінювався у чотирьох (4.5 %) випадках. Наші дані свідчать
 про помітні переваги ЕКоГ над ВЕЕГ в аспекті можливості визначення точної локалізації епілептогенних фокусів, і,
 таким чином, її застосування є доцільним при хірургічному
 лікуванні ТЕ.
en
Інститут фізіології ім. О.О. Богомольця НАН України
Нейрофизиология
Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
Застосування тривалої відеоелектроенцефалографіі та електрокортикографії в хірургічному лікуванні темпоральної епілепсії
Article
published earlier
spellingShingle Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
Xiang, J.
Jiang, Yu.
title Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
title_alt Застосування тривалої відеоелектроенцефалографіі та електрокортикографії в хірургічному лікуванні темпоральної епілепсії
title_full Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
title_fullStr Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
title_full_unstemmed Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
title_short Long-Term Video Electroencephalography and Electrocorticography in Temporal Lobe Epilepsy-Related Surgery
title_sort long-term video electroencephalography and electrocorticography in temporal lobe epilepsy-related surgery
url https://nasplib.isofts.kiev.ua/handle/123456789/148185
work_keys_str_mv AT xiangj longtermvideoelectroencephalographyandelectrocorticographyintemporallobeepilepsyrelatedsurgery
AT jiangyu longtermvideoelectroencephalographyandelectrocorticographyintemporallobeepilepsyrelatedsurgery
AT xiangj zastosuvannâtrivaloívídeoelektroencefalografíítaelektrokortikografíívhírurgíčnomulíkuvannítemporalʹnoíepílepsíí
AT jiangyu zastosuvannâtrivaloívídeoelektroencefalografíítaelektrokortikografíívhírurgíčnomulíkuvannítemporalʹnoíepílepsíí