Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root

There are limited data on structural and functional changes in motor endplates and
 muscle fibers in the target muscle following amputation of the 7th cervical nerve root, a
 transplantation-related procedure in surgical treatment in the case of avulsions of the brachial
 ple...

Повний опис

Збережено в:
Бібліографічні деталі
Опубліковано в: :Нейрофизиология
Дата:2014
Автори: Zhu, Y., Xu, L., Xu, J.G., Gu, Y.D.
Формат: Стаття
Мова:Англійська
Опубліковано: Інститут фізіології ім. О.О. Богомольця НАН України 2014
Онлайн доступ:https://nasplib.isofts.kiev.ua/handle/123456789/148260
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root / Z. Jiang, Y. Zhu, L. Xu, J.G. Xu, Y.D. Gu // Нейрофизиология. — 2014. — Т. 46, № 1. — С. 63-69. — Бібліогр.: 41 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862745986263154688
author Zhu, Y.
Xu, L.
Xu, J.G.
Gu, Y.D.
author_facet Zhu, Y.
Xu, L.
Xu, J.G.
Gu, Y.D.
citation_txt Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root / Z. Jiang, Y. Zhu, L. Xu, J.G. Xu, Y.D. Gu // Нейрофизиология. — 2014. — Т. 46, № 1. — С. 63-69. — Бібліогр.: 41 назв. — англ.
collection DSpace DC
container_title Нейрофизиология
description There are limited data on structural and functional changes in motor endplates and
 muscle fibers in the target muscle following amputation of the 7th cervical nerve root, a
 transplantation-related procedure in surgical treatment in the case of avulsions of the brachial
 plexus roots. We examined functional changes in these structures using stimulated singlefiber electromyography (sSF-EMG) in an animal model. Unilateral amputation of the 7th
 cervical nerve root was performed in 36 male rats, and the m. triceps brachii muscle was
 tested by sSF-EMG at different time points. We observed significant differences in the jitter
 (mean consecutive difference, MCD, of the latencies between adjacent muscle fibers) at postamputation weeks 1, 2, 4, and 6. The post-operation fiber density (FD) values within the
 zone of effective stimulation also gradually increased. At post-amputation weeks 8 and 12,
 the jitter values returned to normal levels, whereas FD values continued to rise. Our results
 indicate that the post-amputation compensatory processes in the target muscles of the 7th
 cervical nerve root are completed at 9-12 weeks after amputation. Дані щодо структурних та функціональних змін у моторних
 кінцевих пластинках та м’язових волокнах м’яза-цілі після ампутації сьомого шийного нервового корінця (процедури в рамках трансплантаційного хірургічного лікування
 наслідків відриву корінців брахіального сплетіння) поки
 що обмежені. Ми досліджували функціональні зміни в згаданих структурах, використовуючи методику стимуляційної „одноволоконної” електроміографії в умовах експериментальної моделі на тваринах. Унілатеральну ампутацію
 сьомого цервікального нервового корінця було виконано на
 36 щурах-самцях, і триголові м’язи плеча тестувалися за допомогою згаданої ЕМГ-методики в різні часові інтервали.
 Ми виявили істотні відмінності середніх варіацій („дрижання”, jitter, різниць між послідовними величинами) латентних періодів, характерних для прилеглих одне до одного
 м’язових волокон, у перший, другий, четвертий та шостий
 тижні після операційного періоду. В цей час щільність волокон у зоні ефективної стимуляції також поступово зростала.
 На восьмий–12-й тижні післяопераційного періоду значення варіацій („дрижання”) поверталися до нормальних, тоді
 як значення щільності активованих волокон продовжували
 зростати. Наші результати свідчать про те, що післяампутаційні компенсаторні процеси в м’язах-цілях волокон нервового корінця С7 завершуються через дев’ять–12 тижнів після ампутації останнього.
first_indexed 2025-12-07T20:43:59Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-148260
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 0028-2561
language English
last_indexed 2025-12-07T20:43:59Z
publishDate 2014
publisher Інститут фізіології ім. О.О. Богомольця НАН України
record_format dspace
spelling Zhu, Y.
Xu, L.
Xu, J.G.
Gu, Y.D.
2019-02-17T19:05:11Z
2019-02-17T19:05:11Z
2014
Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root / Z. Jiang, Y. Zhu, L. Xu, J.G. Xu, Y.D. Gu // Нейрофизиология. — 2014. — Т. 46, № 1. — С. 63-69. — Бібліогр.: 41 назв. — англ.
0028-2561
https://nasplib.isofts.kiev.ua/handle/123456789/148260
612.743+612.815.2
There are limited data on structural and functional changes in motor endplates and
 muscle fibers in the target muscle following amputation of the 7th cervical nerve root, a
 transplantation-related procedure in surgical treatment in the case of avulsions of the brachial
 plexus roots. We examined functional changes in these structures using stimulated singlefiber electromyography (sSF-EMG) in an animal model. Unilateral amputation of the 7th
 cervical nerve root was performed in 36 male rats, and the m. triceps brachii muscle was
 tested by sSF-EMG at different time points. We observed significant differences in the jitter
 (mean consecutive difference, MCD, of the latencies between adjacent muscle fibers) at postamputation weeks 1, 2, 4, and 6. The post-operation fiber density (FD) values within the
 zone of effective stimulation also gradually increased. At post-amputation weeks 8 and 12,
 the jitter values returned to normal levels, whereas FD values continued to rise. Our results
 indicate that the post-amputation compensatory processes in the target muscles of the 7th
 cervical nerve root are completed at 9-12 weeks after amputation.
Дані щодо структурних та функціональних змін у моторних
 кінцевих пластинках та м’язових волокнах м’яза-цілі після ампутації сьомого шийного нервового корінця (процедури в рамках трансплантаційного хірургічного лікування
 наслідків відриву корінців брахіального сплетіння) поки
 що обмежені. Ми досліджували функціональні зміни в згаданих структурах, використовуючи методику стимуляційної „одноволоконної” електроміографії в умовах експериментальної моделі на тваринах. Унілатеральну ампутацію
 сьомого цервікального нервового корінця було виконано на
 36 щурах-самцях, і триголові м’язи плеча тестувалися за допомогою згаданої ЕМГ-методики в різні часові інтервали.
 Ми виявили істотні відмінності середніх варіацій („дрижання”, jitter, різниць між послідовними величинами) латентних періодів, характерних для прилеглих одне до одного
 м’язових волокон, у перший, другий, четвертий та шостий
 тижні після операційного періоду. В цей час щільність волокон у зоні ефективної стимуляції також поступово зростала.
 На восьмий–12-й тижні післяопераційного періоду значення варіацій („дрижання”) поверталися до нормальних, тоді
 як значення щільності активованих волокон продовжували
 зростати. Наші результати свідчать про те, що післяампутаційні компенсаторні процеси в м’язах-цілях волокон нервового корінця С7 завершуються через дев’ять–12 тижнів після ампутації останнього.
en
Інститут фізіології ім. О.О. Богомольця НАН України
Нейрофизиология
Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
Функціональні зміни в моторних кінцевих пластинках м’яза-цілі після ампутації нервового корінця С7
Article
published earlier
spellingShingle Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
Zhu, Y.
Xu, L.
Xu, J.G.
Gu, Y.D.
title Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
title_alt Функціональні зміни в моторних кінцевих пластинках м’яза-цілі після ампутації нервового корінця С7
title_full Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
title_fullStr Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
title_full_unstemmed Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
title_short Functional changes in motor endplates of the target muscle after amputation of the C7 nerve root
title_sort functional changes in motor endplates of the target muscle after amputation of the c7 nerve root
url https://nasplib.isofts.kiev.ua/handle/123456789/148260
work_keys_str_mv AT zhuy functionalchangesinmotorendplatesofthetargetmuscleafteramputationofthec7nerveroot
AT xul functionalchangesinmotorendplatesofthetargetmuscleafteramputationofthec7nerveroot
AT xujg functionalchangesinmotorendplatesofthetargetmuscleafteramputationofthec7nerveroot
AT guyd functionalchangesinmotorendplatesofthetargetmuscleafteramputationofthec7nerveroot
AT zhuy funkcíonalʹnízmínivmotornihkíncevihplastinkahmâzacílípíslâamputacíínervovogokoríncâs7
AT xul funkcíonalʹnízmínivmotornihkíncevihplastinkahmâzacílípíslâamputacíínervovogokoríncâs7
AT xujg funkcíonalʹnízmínivmotornihkíncevihplastinkahmâzacílípíslâamputacíínervovogokoríncâs7
AT guyd funkcíonalʹnízmínivmotornihkíncevihplastinkahmâzacílípíslâamputacíínervovogokoríncâs7