Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme

The article is the continuation of the theme highlighted in the previous article with same title. The new article evaluates the results of digital protective relays (DPR) testing for immunity to the E1 component of High-altitude Electromagnetic Pulse (HEMP) and to Intentional Electromagnetic Interf...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Електротехніка і електромеханіка
Datum:2015
1. Verfasser: Gurevich, V.
Format: Artikel
Sprache:English
Veröffentlicht: Інститут технічних проблем магнетизму НАН України 2015
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/149394
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme / V. Gurevich // Електротехніка і електромеханіка. — 2015. — № 6. — С. 66–69. — Бібліогр.: 7 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-149394
record_format dspace
spelling Gurevich, V.
2019-02-21T13:28:26Z
2019-02-21T13:28:26Z
2015
Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme / V. Gurevich // Електротехніка і електромеханіка. — 2015. — № 6. — С. 66–69. — Бібліогр.: 7 назв. — англ.
2074-272X
DOI: https://doi.org/10.20998/2074-272X.2015.6.12
https://nasplib.isofts.kiev.ua/handle/123456789/149394
316
The article is the continuation of the theme highlighted in the previous article with same title. The new article evaluates the results of digital protective relays (DPR) testing for immunity to the E1 component of High-altitude Electromagnetic Pulse (HEMP) and to Intentional Electromagnetic Interferences (IEMI) impacts, conducted by some independent American organizations; discusses the features of relay protection devices as well as clarifies and supplements the procedure for testing these devices. Due to methodology errors during the DPR tests conducted by mentioned organizations earlier, they cannot be considered as satisfactory and their results as meaningful. At the moment there are no reliable data on the level of DPR immunity to IDEI, which suggests that the test should be conducted further.
Статья является продолжением темы, рассмотренной в предыдущей статье с таким же названием. В новой статье оцениваются результаты испытаний микропроцессорных устройств релейной защиты (МУРЗ) на устойчивость к компоненту E1 электромагнитного импульса высотного ядерного взрыва (ЭМИ ЯВ) и к преднамеренным дистанционным электромагнитным воздействиям (ПДДВ), приводимые некоторыми независимыми американскими организациями; обсуждаются особенности методики их испытаний. Показано, что из-за ошибок в методологии испытаний, результаты, полученные упомянутыми выше организациями нельзя считать достоверными. В настоящее время нет никаких надежных данных об уровне устойчивости МУРЗ к ПДДВ, что указывает на необходимость проведения дополнительных испытаний.
en
Інститут технічних проблем магнетизму НАН України
Електротехніка і електромеханіка
Дискусії
Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
spellingShingle Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
Gurevich, V.
Дискусії
title_short Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
title_full Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
title_fullStr Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
title_full_unstemmed Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme
title_sort problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. continuation of the theme
author Gurevich, V.
author_facet Gurevich, V.
topic Дискусії
topic_facet Дискусії
publishDate 2015
language English
container_title Електротехніка і електромеханіка
publisher Інститут технічних проблем магнетизму НАН України
format Article
description The article is the continuation of the theme highlighted in the previous article with same title. The new article evaluates the results of digital protective relays (DPR) testing for immunity to the E1 component of High-altitude Electromagnetic Pulse (HEMP) and to Intentional Electromagnetic Interferences (IEMI) impacts, conducted by some independent American organizations; discusses the features of relay protection devices as well as clarifies and supplements the procedure for testing these devices. Due to methodology errors during the DPR tests conducted by mentioned organizations earlier, they cannot be considered as satisfactory and their results as meaningful. At the moment there are no reliable data on the level of DPR immunity to IDEI, which suggests that the test should be conducted further. Статья является продолжением темы, рассмотренной в предыдущей статье с таким же названием. В новой статье оцениваются результаты испытаний микропроцессорных устройств релейной защиты (МУРЗ) на устойчивость к компоненту E1 электромагнитного импульса высотного ядерного взрыва (ЭМИ ЯВ) и к преднамеренным дистанционным электромагнитным воздействиям (ПДДВ), приводимые некоторыми независимыми американскими организациями; обсуждаются особенности методики их испытаний. Показано, что из-за ошибок в методологии испытаний, результаты, полученные упомянутыми выше организациями нельзя считать достоверными. В настоящее время нет никаких надежных данных об уровне устойчивости МУРЗ к ПДДВ, что указывает на необходимость проведения дополнительных испытаний.
issn 2074-272X
url https://nasplib.isofts.kiev.ua/handle/123456789/149394
citation_txt Problems in testing digital protective relay for immunity to intentional destructive electromagnetic impacts. Continuation of the theme / V. Gurevich // Електротехніка і електромеханіка. — 2015. — № 6. — С. 66–69. — Бібліогр.: 7 назв. — англ.
work_keys_str_mv AT gurevichv problemsintestingdigitalprotectiverelayforimmunitytointentionaldestructiveelectromagneticimpactscontinuationofthetheme
first_indexed 2025-12-07T15:45:08Z
last_indexed 2025-12-07T15:45:08Z
_version_ 1850864890177126400