Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes
Hermia’s models for cross flow filtration were used to investigate the fouling mechanisms of mullite-alumina ceramic membranes in treatment of oily wastewaters in a hybrid microfiltration-powdered activated carbon process (MF-PAC). Results show that cake filtration model can be applied for predictio...
Saved in:
| Published in: | Химия и технология воды |
|---|---|
| Date: | 2016 |
| Main Authors: | , |
| Format: | Article |
| Language: | English |
| Published: |
Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України
2016
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/160801 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes / Mohsen Abbasi, Aboozar Taheri // Химия и технология воды. — 2016. — Т. 38, № 3. — С. 311-323. — Бібліогр.: 18 назв. — рос. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862544313367396352 |
|---|---|
| author | Mohsen Abbasi Aboozar Taheri |
| author_facet | Mohsen Abbasi Aboozar Taheri |
| citation_txt | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes / Mohsen Abbasi, Aboozar Taheri // Химия и технология воды. — 2016. — Т. 38, № 3. — С. 311-323. — Бібліогр.: 18 назв. — рос. |
| collection | DSpace DC |
| container_title | Химия и технология воды |
| description | Hermia’s models for cross flow filtration were used to investigate the fouling mechanisms of mullite-alumina ceramic membranes in treatment of oily wastewaters in a hybrid microfiltration-powdered activated carbon process (MF-PAC). Results show that cake filtration model can be applied for prediction of permeation flux decline for MF and MF-PAC process up to 400 ppm PAC. The complete pore blocking model and the intermediate pore blocking model can predict permeation flux decline with time for MF-PAC with 800 and 1200 ppm PAC respectively. Average error for prediction of permeation flux with cake filtration model is 2.19% for MF process and 2.16; 2.06 and 1.31% for MF-PAC process with 100; 200 and 400 ppm PAC respectively. Also for MF-PAC process with 800 and 1200 ppm PAC, average error for prediction of permeation flux with complete pore blocking model and intermediate pore blocking model was 6.11 and 6% respectively.
|
| first_indexed | 2025-11-25T00:00:19Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-160801 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| issn | 0204-3556 |
| language | English |
| last_indexed | 2025-11-25T00:00:19Z |
| publishDate | 2016 |
| publisher | Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України |
| record_format | dspace |
| spelling | Mohsen Abbasi Aboozar Taheri 2019-11-19T18:16:57Z 2019-11-19T18:16:57Z 2016 Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes / Mohsen Abbasi, Aboozar Taheri // Химия и технология воды. — 2016. — Т. 38, № 3. — С. 311-323. — Бібліогр.: 18 назв. — рос. 0204-3556 https://nasplib.isofts.kiev.ua/handle/123456789/160801 Hermia’s models for cross flow filtration were used to investigate the fouling mechanisms of mullite-alumina ceramic membranes in treatment of oily wastewaters in a hybrid microfiltration-powdered activated carbon process (MF-PAC). Results show that cake filtration model can be applied for prediction of permeation flux decline for MF and MF-PAC process up to 400 ppm PAC. The complete pore blocking model and the intermediate pore blocking model can predict permeation flux decline with time for MF-PAC with 800 and 1200 ppm PAC respectively. Average error for prediction of permeation flux with cake filtration model is 2.19% for MF process and 2.16; 2.06 and 1.31% for MF-PAC process with 100; 200 and 400 ppm PAC respectively. Also for MF-PAC process with 800 and 1200 ppm PAC, average error for prediction of permeation flux with complete pore blocking model and intermediate pore blocking model was 6.11 and 6% respectively. en Інститут колоїдної хімії та хімії води ім. А.В. Думанського НАН України Химия и технология воды Технология водоподготовки и деминерализация вод Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes Article published earlier |
| spellingShingle | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes Mohsen Abbasi Aboozar Taheri Технология водоподготовки и деминерализация вод |
| title | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes |
| title_full | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes |
| title_fullStr | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes |
| title_full_unstemmed | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes |
| title_short | Selecting model for treatmentof oily wastewater by MF-PAC hybrid process using mullite-alumina ceramic membranes |
| title_sort | selecting model for treatmentof oily wastewater by mf-pac hybrid process using mullite-alumina ceramic membranes |
| topic | Технология водоподготовки и деминерализация вод |
| topic_facet | Технология водоподготовки и деминерализация вод |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/160801 |
| work_keys_str_mv | AT mohsenabbasi selectingmodelfortreatmentofoilywastewaterbymfpachybridprocessusingmullitealuminaceramicmembranes AT aboozartaheri selectingmodelfortreatmentofoilywastewaterbymfpachybridprocessusingmullitealuminaceramicmembranes |