Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator

Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft X-ray emission have been designed for the Uragan-2M stellarator. The power of soft X-ray filtered by different filters has been calculated numerically in order to optimize applicability of two foils temper...

Full description

Saved in:
Bibliographic Details
Date:2010
Main Author: Dreval, M.B.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2010
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/17444
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator / M.B. Dreval // Вопросы атомной науки и техники. — 2010. — № 6. — С. 11-13. — Бібліогр.: 8 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862633347270836224
author Dreval, M.B.
author_facet Dreval, M.B.
citation_txt Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator / M.B. Dreval // Вопросы атомной науки и техники. — 2010. — № 6. — С. 11-13. — Бібліогр.: 8 назв. — англ.
collection DSpace DC
description Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft X-ray emission have been designed for the Uragan-2M stellarator. The power of soft X-ray filtered by different filters has been calculated numerically in order to optimize applicability of two foils temperature measurement technique. In the initial operation, a Be foil with a thickness of 10 μm and Al filter of 3 μm have been chosen to test signal strength and to test two foils temperature measurement technique. SXR photodiodes photocurrent amplifiers with bandwidth up to 5MHz have been designed for signal amplification. Digitizers with 12 bit resolution and sampling rate up to 8 MS/s have been tested for SXR data acquisition. Два миниатюрных датчика для измерения временного поведения и пространственного распределения излучения мягкого рентгена были спроектированы для стелларатора Ураган-2М. Мощность мягкого рентгена, проходящего через различные фильтры, была рассчитана численно с целью оптимизации применимости техники измерения температуры плазмы, базирующейся на двух фольгах. В начальных экспериментах для тестирования величины сигнала мягкого рентгена и проверки техники двух фольг были выбраны 10 мкм-бериллиевая и 3 мкм-алюминиевая фольги. Были разработаны усилители фототока фотодиода мягкого рентгена с частотной полосой до 5 МГц. Аналогово-цифровые преобразователи с разрешением 12 бит и частотой оцифровки до 8 МГц были протестированы для их применения в диагностике мягкого рентгена. Два мініатюрних датчики для виміру тимчасового поводження й просторового розподілу випромінювання м'якого рентгена були спроектовані для стелларатора Ураган-2М. Потужність м'якого рентгена, що проходить через різні фільтри, була розрахована чисельно з метою оптимізації застосовності техніки виміру температури плазми, базованої на двох фольгах. У початкових експериментах для тестування величини сигналу м'якого рентгена й перевірки техніки двох фольг було обрано 10 мкм-берилієву і 3 мкм-алюмінієву фольги. Було розроблено підсилювачі фотоструму фотодіода м'якого рентгена із частотною смугою до 5 МГц. Аналогово-цифрові перетворювачі з розділенням 12 біт і частотою оцифровки до 8 МГц були протестовані для
 їхнього застосування в діагностиці м'якого рентгена.
first_indexed 2025-11-30T14:17:50Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-17444
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-11-30T14:17:50Z
publishDate 2010
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Dreval, M.B.
2011-02-26T18:41:58Z
2011-02-26T18:41:58Z
2010
Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator / M.B. Dreval // Вопросы атомной науки и техники. — 2010. — № 6. — С. 11-13. — Бібліогр.: 8 назв. — англ.
1562-6016
https://nasplib.isofts.kiev.ua/handle/123456789/17444
Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft X-ray emission have been designed for the Uragan-2M stellarator. The power of soft X-ray filtered by different filters has been calculated numerically in order to optimize applicability of two foils temperature measurement technique. In the initial operation, a Be foil with a thickness of 10 μm and Al filter of 3 μm have been chosen to test signal strength and to test two foils temperature measurement technique. SXR photodiodes photocurrent amplifiers with bandwidth up to 5MHz have been designed for signal amplification. Digitizers with 12 bit resolution and sampling rate up to 8 MS/s have been tested for SXR data acquisition.
Два миниатюрных датчика для измерения временного поведения и пространственного распределения излучения мягкого рентгена были спроектированы для стелларатора Ураган-2М. Мощность мягкого рентгена, проходящего через различные фильтры, была рассчитана численно с целью оптимизации применимости техники измерения температуры плазмы, базирующейся на двух фольгах. В начальных экспериментах для тестирования величины сигнала мягкого рентгена и проверки техники двух фольг были выбраны 10 мкм-бериллиевая и 3 мкм-алюминиевая фольги. Были разработаны усилители фототока фотодиода мягкого рентгена с частотной полосой до 5 МГц. Аналогово-цифровые преобразователи с разрешением 12 бит и частотой оцифровки до 8 МГц были протестированы для их применения в диагностике мягкого рентгена.
Два мініатюрних датчики для виміру тимчасового поводження й просторового розподілу випромінювання м'якого рентгена були спроектовані для стелларатора Ураган-2М. Потужність м'якого рентгена, що проходить через різні фільтри, була розрахована чисельно з метою оптимізації застосовності техніки виміру температури плазми, базованої на двох фольгах. У початкових експериментах для тестування величини сигналу м'якого рентгена й перевірки техніки двох фольг було обрано 10 мкм-берилієву і 3 мкм-алюмінієву фольги. Було розроблено підсилювачі фотоструму фотодіода м'якого рентгена із частотною смугою до 5 МГц. Аналогово-цифрові перетворювачі з розділенням 12 біт і частотою оцифровки до 8 МГц були протестовані для
 їхнього застосування в діагностиці м'якого рентгена.
This work is supported by the STSU project 4216.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Магнитное удержание
Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
Разработка многохордового набора детекторов мягкого рентгена для стелларатора Ураган-2М
Розробка багатохордового набору детекторів м'якого рентгена для стелларатора Ураган-2М
Article
published earlier
spellingShingle Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
Dreval, M.B.
Магнитное удержание
title Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
title_alt Разработка многохордового набора детекторов мягкого рентгена для стелларатора Ураган-2М
Розробка багатохордового набору детекторів м'якого рентгена для стелларатора Ураган-2М
title_full Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
title_fullStr Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
title_full_unstemmed Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
title_short Design of multichord soft x-ray detection arrays for the Uragan-2M stellarator
title_sort design of multichord soft x-ray detection arrays for the uragan-2m stellarator
topic Магнитное удержание
topic_facet Магнитное удержание
url https://nasplib.isofts.kiev.ua/handle/123456789/17444
work_keys_str_mv AT drevalmb designofmultichordsoftxraydetectionarraysfortheuragan2mstellarator
AT drevalmb razrabotkamnogohordovogonaboradetektorovmâgkogorentgenadlâstellaratorauragan2m
AT drevalmb rozrobkabagatohordovogonaborudetektorívmâkogorentgenadlâstellaratorauragan2m