Recent studies of the ion emission from high-current PF-1000 experiments

The paper describes diagnostics of fast ion beams emitted from a large PF-1000 facility operated at 21…27 kV, 290…480 kJ. Those beams were measured with pinhole cameras and PM-355 nuclear track detectors, placed at different angles to the discharge axis. The measurements showed a complex spatial str...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2010
Hauptverfasser: Skladnik-Sadowska, E., Sadowski, M.J., Czaus, K., Malinowski, K., Kwiatkowski, R., Zebrowski, J., Karpinski, L., Paduch, M., Scholz, M., Garkusha, I.E.
Format: Artikel
Sprache:Englisch
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2010
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/17503
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Recent studies of the ion emission from high-current PF-1000 experiments / E. Skladnik-Sadowska, M.J. Sadowski, K. Czaus, K. Malinowski, R. Kwiatkowski, J. Zebrowski, L. Karpinski, M. Paduch, M. Scholz, I.E. Garkusha // Вопросы атомной науки и техники. — 2010. — № 6. — С. 199-201. — Бібліогр.: 5 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862697793174372352
author Skladnik-Sadowska, E.
Sadowski, M.J.
Czaus, K.
Malinowski, K.
Kwiatkowski, R.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I.E.
author_facet Skladnik-Sadowska, E.
Sadowski, M.J.
Czaus, K.
Malinowski, K.
Kwiatkowski, R.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I.E.
citation_txt Recent studies of the ion emission from high-current PF-1000 experiments / E. Skladnik-Sadowska, M.J. Sadowski, K. Czaus, K. Malinowski, R. Kwiatkowski, J. Zebrowski, L. Karpinski, M. Paduch, M. Scholz, I.E. Garkusha // Вопросы атомной науки и техники. — 2010. — № 6. — С. 199-201. — Бібліогр.: 5 назв. — англ.
collection DSpace DC
description The paper describes diagnostics of fast ion beams emitted from a large PF-1000 facility operated at 21…27 kV, 290…480 kJ. Those beams were measured with pinhole cameras and PM-355 nuclear track detectors, placed at different angles to the discharge axis. The measurements showed a complex spatial structure of the fast ion beams. Measurements behind an axial channel in the inner electrode have shown that some ion beams are emitted also in the upstream direction. The ion energy spectra were measured with a miniature Thomson-type spectrometer. Time-resolved measurements of ions were performed with miniature scintillation detectors placed behind a pinhole.
first_indexed 2025-12-07T16:31:03Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-17503
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-12-07T16:31:03Z
publishDate 2010
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Skladnik-Sadowska, E.
Sadowski, M.J.
Czaus, K.
Malinowski, K.
Kwiatkowski, R.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I.E.
2011-02-26T23:20:36Z
2011-02-26T23:20:36Z
2010
Recent studies of the ion emission from high-current PF-1000 experiments / E. Skladnik-Sadowska, M.J. Sadowski, K. Czaus, K. Malinowski, R. Kwiatkowski, J. Zebrowski, L. Karpinski, M. Paduch, M. Scholz, I.E. Garkusha // Вопросы атомной науки и техники. — 2010. — № 6. — С. 199-201. — Бібліогр.: 5 назв. — англ.
1562-6016
https://nasplib.isofts.kiev.ua/handle/123456789/17503
The paper describes diagnostics of fast ion beams emitted from a large PF-1000 facility operated at 21…27 kV, 290…480 kJ. Those beams were measured with pinhole cameras and PM-355 nuclear track detectors, placed at different angles to the discharge axis. The measurements showed a complex spatial structure of the fast ion beams. Measurements behind an axial channel in the inner electrode have shown that some ion beams are emitted also in the upstream direction. The ion energy spectra were measured with a miniature Thomson-type spectrometer. Time-resolved measurements of ions were performed with miniature scintillation detectors placed behind a pinhole.
This work was realized in a frame of the Agreement about Scientific Collaboration between Poland and Ukraine. It was supported by a grant (No. 584/N-Ukraina/2009/0) from the Ministry of Science and Higher Education, Poland.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Диагностика плазмы
Recent studies of the ion emission from high-current PF-1000 experiments
Новейшие результаты экспериментов по исследованию ионных пучков, эмитируемых на ПФ-1000
Article
published earlier
spellingShingle Recent studies of the ion emission from high-current PF-1000 experiments
Skladnik-Sadowska, E.
Sadowski, M.J.
Czaus, K.
Malinowski, K.
Kwiatkowski, R.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I.E.
Диагностика плазмы
title Recent studies of the ion emission from high-current PF-1000 experiments
title_alt Новейшие результаты экспериментов по исследованию ионных пучков, эмитируемых на ПФ-1000
title_full Recent studies of the ion emission from high-current PF-1000 experiments
title_fullStr Recent studies of the ion emission from high-current PF-1000 experiments
title_full_unstemmed Recent studies of the ion emission from high-current PF-1000 experiments
title_short Recent studies of the ion emission from high-current PF-1000 experiments
title_sort recent studies of the ion emission from high-current pf-1000 experiments
topic Диагностика плазмы
topic_facet Диагностика плазмы
url https://nasplib.isofts.kiev.ua/handle/123456789/17503
work_keys_str_mv AT skladniksadowskae recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT sadowskimj recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT czausk recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT malinowskik recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT kwiatkowskir recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT zebrowskij recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT karpinskil recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT paduchm recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT scholzm recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT garkushaie recentstudiesoftheionemissionfromhighcurrentpf1000experiments
AT skladniksadowskae noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT sadowskimj noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT czausk noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT malinowskik noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT kwiatkowskir noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT zebrowskij noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT karpinskil noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT paduchm noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT scholzm noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000
AT garkushaie noveišierezulʹtatyéksperimentovpoissledovaniûionnyhpučkovémitiruemyhnapf1000