X-ray line spectrometry in experiments with the aluminium Z-pinch

X-ray line spectrometry with temporal resolution was developed for registration of [He]- and [H]-like aluminium ions spectrum. It was chosen a scheme with scintillator converting X-ray spectrum into the visible image, which was transferred through the flexible optical fiber to the entrance slit of t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2010
Hauptverfasser: Anan’ev, S.S., Dan’ko, S.A., Kalinin, Yu.G., Ye Fan, Qin Yi, Jiang Shuqing, Xue Feibiao, Li Zhenghong, Yang Jianlun, Xu Rongkun
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2010
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/17505
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:X-ray line spectrometry in experiments with the aluminium Z-pinch / S.S. Anan’ev, S.A. Dan’ko, Yu.G. Kalinin, Fan Ye, Yi Qin, Shuqing Jiang, Feibiao Xue, Zhenghong Li, Jianlun Yang, Rongkun Xu // Вопросы атомной науки и техники. — 2010. — № 6. — С. 205-207. — Бібліогр.: 11 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:X-ray line spectrometry with temporal resolution was developed for registration of [He]- and [H]-like aluminium ions spectrum. It was chosen a scheme with scintillator converting X-ray spectrum into the visible image, which was transferred through the flexible optical fiber to the entrance slit of the streak camera. In Z-pinch experiment on the high current S-300 generator the aluminium line spectrum was registered with nanosecond time resolution. The simultaneous appearance of [He]- and [H]-like aluminium ions radiation was observed, that is the evidence of high electron temperature existence in the plasma for a long time before the main part of the load mass comes to the axis. The noticeably changing of radiating plasma parameters was found after the computer treatment of line spectra: the electron concentration is varied in five times ((3…14)×10^19 cm^-3), electron temperature in three times (0.3…1 keV), ion temperature in five times (20…100 keV), – during 50 ns. The great difference between the electron and ion temperature holds during all radiation time and demonstrates the ineffective energy transfer from the kinetic energy of ions to electron.