Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping
A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power ac...
Gespeichert in:
| Veröffentlicht in: | Физика низких температур |
|---|---|
| Datum: | 1997 |
| Hauptverfasser: | , , , , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України
1997
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/175577 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-175577 |
|---|---|
| record_format |
dspace |
| spelling |
Batey, G.J. White, J.P. Duncan, W.D. Simpson, A.F. Mikheev, V.A. 2021-02-01T18:55:20Z 2021-02-01T18:55:20Z 1997 Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ. 0132-6414 PACS: 07.20.Мс https://nasplib.isofts.kiev.ua/handle/123456789/175577 A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power achieved is 40 at 100 mK. The DR is fitted with 6-mm line-of-sight access down to the mixing chamber. A distinguishing feature of this refrigerator is the absence of a conventional gas-handling system, which makes it easy to transport in a small car and quickly commission in a new laboratory within a few hours. The authors are very grateful to Alvin Adams and Terry Janaway for their incredible efforts and skills during the construction and testing of this refrigerator. en Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України Физика низких температур Техника свеpхнизких темпеpатуp Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping |
| spellingShingle |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping Batey, G.J. White, J.P. Duncan, W.D. Simpson, A.F. Mikheev, V.A. Техника свеpхнизких темпеpатуp |
| title_short |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping |
| title_full |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping |
| title_fullStr |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping |
| title_full_unstemmed |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping |
| title_sort |
ultralow temperatures in a transport vessel: a dilution refrigerator to achieve 30 mk by continuous adsorption pumping |
| author |
Batey, G.J. White, J.P. Duncan, W.D. Simpson, A.F. Mikheev, V.A. |
| author_facet |
Batey, G.J. White, J.P. Duncan, W.D. Simpson, A.F. Mikheev, V.A. |
| topic |
Техника свеpхнизких темпеpатуp |
| topic_facet |
Техника свеpхнизких темпеpатуp |
| publishDate |
1997 |
| language |
English |
| container_title |
Физика низких температур |
| publisher |
Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України |
| format |
Article |
| description |
A novel design of dilution refrigerator (DR) is described for continuous operation inside a transport dewar with a neck diameter more than 51 mm. The time required for cooling the mixing chamber from room temperature to 30 mK is 3.5–4.5 h. Warming up to 300 K requires 0.5–1.0 h. The cooling power achieved is 40 at 100 mK. The DR is fitted with 6-mm line-of-sight access down to the mixing chamber. A distinguishing feature of this refrigerator is the absence of a conventional gas-handling system, which makes it easy to transport in a small car and quickly commission in a new laboratory within a few hours.
|
| issn |
0132-6414 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/175577 |
| fulltext |
|
| citation_txt |
Ultralow temperatures in a transport vessel: A dilution refrigerator to achieve 30 mK by continuous adsorption pumping / G.J. Batey, J.P. White, W.D. Duncan, A.F. Simpson and V.A. Mikheev // Физика низких температур. — 1997. — Т. 23, № 5-6. — С. 655-658. — Бібліогр.: 11 назв. — англ. |
| work_keys_str_mv |
AT bateygj ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping AT whitejp ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping AT duncanwd ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping AT simpsonaf ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping AT mikheevva ultralowtemperaturesinatransportvesseladilutionrefrigeratortoachieve30mkbycontinuousadsorptionpumping |
| first_indexed |
2025-11-25T23:10:34Z |
| last_indexed |
2025-11-25T23:10:34Z |
| _version_ |
1850579147029479424 |