Ionometric Method for Determination of Concentrations of Microelements in Research of Digital Medicine
The purpose of the paper is to develop an algorithm for processing data measuring alkali and alkaline earth metal concentrations by a new electrochemical method of chronoionometry, based on the use of the principles of direct potentiometry and ion-selective electrodes on the inversion chronopotentio...
Gespeichert in:
| Veröffentlicht in: | Cybernetics and computer engineering |
|---|---|
| Datum: | 2020 |
| Hauptverfasser: | , , , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
Міжнародний науково-навчальний центр інформаційних технологій і систем НАН України та МОН України
2020
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/179368 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Ionometric Method for Determination of Concentrations of Microelements in Research of Digital Medicine / I.V. Surovtsev, P.Yu. Velykyi, V.M. Galimova, M.V. Sarkisova // Cybernetics and computer engineering. — 2020. — № 4 (202). — С. 25-43. — Бібліогр.: 37 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| Zusammenfassung: | The purpose of the paper is to develop an algorithm for processing data measuring alkali and alkaline earth metal concentrations by a new electrochemical method of chronoionometry, based on the use of the principles of direct potentiometry and ion-selective electrodes on the inversion chronopotentiometry device. Results. The method of chronoionometry was developed and testing was performed on the device of stripping chronopotentiometry "Analyzer SCP" for determining the concentrations of potassium, sodium and calcium in model aqueous solutions. Analytical system "Analyzer SCP" includes five electrochemical research methods: the method of stripping chronopotentiometry (SCP); pulse method SCP (PSCP); differential pulse method SCP (DPSCP); oxidative pulse method SCP (OPSCP); chronoionometric method (CHI). The algorithm for processing concentration measurement data by chronoionometry makes it possible to select specific potential measurements and not take into account unstable values. Measurements are performed by the method of multiple standard additives to ensure controllability of the analysis results.
Мета статті — розробити алгоритм оброблення даних вимірювання концентрацій лужних та лужноземельних металів новим електрохімічним методом хроноіонометрії, основаним на використанні принципів прямої потенціометрії та іон-селективних електродів на приладі інверсійної хронопотенціометрії. Результати. Розроблено метод хроноіонометрії та проведено тестування на приладі інверсійної хронопотенціометрії «Аналізатор ІХП» визначення концентрацій калію, натрію та кальцію в модельних водних розчинах.
|
|---|---|