Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV

The main advantages of using silicon semiconductor detectors in dosimetry in comparison with traditional detectors are considered. The shortcomings are analyzed and possible methods for their elimination are proposed. One of the proposed methods makes it possible to increase the efficiency of detect...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2020
Hauptverfasser: Dubina, V.N., Maslov, N.I., Shlyahov, I.N.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2020
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/194575
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV / V.N. Dubina, N.I. Maslov, I.N. Shlyahov // Problems of atomic science and tecnology. — 2020. — № 5. — С. 105-110. — Бібліогр.: 9 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-194575
record_format dspace
spelling Dubina, V.N.
Maslov, N.I.
Shlyahov, I.N.
2023-11-27T14:43:13Z
2023-11-27T14:43:13Z
2020
Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV / V.N. Dubina, N.I. Maslov, I.N. Shlyahov // Problems of atomic science and tecnology. — 2020. — № 5. — С. 105-110. — Бібліогр.: 9 назв. — англ.
1562-6016
PACS: 03.65.Pm, 03.65.Ge, 61.80.Mk
https://nasplib.isofts.kiev.ua/handle/123456789/194575
The main advantages of using silicon semiconductor detectors in dosimetry in comparison with traditional detectors are considered. The shortcomings are analyzed and possible methods for their elimination are proposed. One of the proposed methods makes it possible to increase the efficiency of detecting gamma quantum in the energy range 0.1…10MeV. The requirements are formulated to optimize the design of detectors operating in a wide range of dose rates and gamma radiation energies by computer simulation. Mathematical calculations and computer simulations determine the dosimeter design, materials and thicknesses γ–converter. The mechanisms of modeling the absorbed dose in air and ambient dose in silicon detectors with a thickness of 300 μm, sizes (5×5)mm² and (1.8×1.8)mm², in the range of incident γ–ray energies from 5keV to 10 MeV are presented.
Розглянуто основні переваги застосування кремнієвих напівпровідникових детекторів у задачах дозиметрії в порівнянні з традиційними детекторами. Проаналізовано недоліки та запропоновані можливі методи їх усунення. Один із запропонованих методів дозволяє збільшити ефективність реєстрації гамма-квантів у діапазоні енергій 0,1…10 МэВ. Сформульовано вимоги, необхідні для оптимізації конструкції детекторів, які працюють у широкому діапазоні потужностей доз і енергії гамма–випромінювання, методом комп’ютерного моделювання. Проведені математичні розрахунки і комп’ютерне моделювання визначають конструкцію дозиметра, матеріали і товщину γ–конвертера. Наводяться механізми моделювання поглиненої дози в повітрі і амбієнтної дози в кремнієвих детекторах товщиною від 300 мкм, розмірами (5×5)мм² и (1,8×1,8)мм², у діапазоні енергій падаючого γ–випромінювання від 5 кеВ до 10 МеВ.
Рассмотрены основные преимущества применения кремниевых полупроводниковых детекторов в задачах дозиметрии по сравнению с традиционными детекторами. Проанализированы недостатки и предложены возможные методы их устранения. Один из предложенных методов позволяет увеличить эффективность регистрации гамма-квантов в диапазоне энергий 0,1…10 МэВ. Сформулированы требования, необходимые для оптимизации конструкции детекторов, работающих в широком диапазоне мощностей доз и энергии гамма–излучения, методом компьютерного моделирования. Проведенные математические расчеты и компьютерное моделирование определяют конструкцию дозиметра, материалы и толщину γ–конвертера. Приводятся механизмы моделирования поглощенной дозы в воздухе и амбиентной дозы в кремниевых детекторах толщиной от 300 мкм, размерами (5×5)мм² и (1,8×1,8)мм², в диапазоне энергий падающего γ–излучения от 5 кэВ до 10 МэВ.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Computing and modelling systems
Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
Моделювання відгуку планарного кремнієвого детектора при вимірюванні потужності експозиційної дози у діапазоні енергій від 5 кеВ до 10 МеВ
Моделирование отклика планарного кремниевого детектора при измерении мощности экспозиционной дозы в диапазоне энергий от 5 кэВ до 10 МэВ
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
spellingShingle Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
Dubina, V.N.
Maslov, N.I.
Shlyahov, I.N.
Computing and modelling systems
title_short Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
title_full Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
title_fullStr Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
title_full_unstemmed Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV
title_sort modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 kev to 10mev
author Dubina, V.N.
Maslov, N.I.
Shlyahov, I.N.
author_facet Dubina, V.N.
Maslov, N.I.
Shlyahov, I.N.
topic Computing and modelling systems
topic_facet Computing and modelling systems
publishDate 2020
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Моделювання відгуку планарного кремнієвого детектора при вимірюванні потужності експозиційної дози у діапазоні енергій від 5 кеВ до 10 МеВ
Моделирование отклика планарного кремниевого детектора при измерении мощности экспозиционной дозы в диапазоне энергий от 5 кэВ до 10 МэВ
description The main advantages of using silicon semiconductor detectors in dosimetry in comparison with traditional detectors are considered. The shortcomings are analyzed and possible methods for their elimination are proposed. One of the proposed methods makes it possible to increase the efficiency of detecting gamma quantum in the energy range 0.1…10MeV. The requirements are formulated to optimize the design of detectors operating in a wide range of dose rates and gamma radiation energies by computer simulation. Mathematical calculations and computer simulations determine the dosimeter design, materials and thicknesses γ–converter. The mechanisms of modeling the absorbed dose in air and ambient dose in silicon detectors with a thickness of 300 μm, sizes (5×5)mm² and (1.8×1.8)mm², in the range of incident γ–ray energies from 5keV to 10 MeV are presented. Розглянуто основні переваги застосування кремнієвих напівпровідникових детекторів у задачах дозиметрії в порівнянні з традиційними детекторами. Проаналізовано недоліки та запропоновані можливі методи їх усунення. Один із запропонованих методів дозволяє збільшити ефективність реєстрації гамма-квантів у діапазоні енергій 0,1…10 МэВ. Сформульовано вимоги, необхідні для оптимізації конструкції детекторів, які працюють у широкому діапазоні потужностей доз і енергії гамма–випромінювання, методом комп’ютерного моделювання. Проведені математичні розрахунки і комп’ютерне моделювання визначають конструкцію дозиметра, матеріали і товщину γ–конвертера. Наводяться механізми моделювання поглиненої дози в повітрі і амбієнтної дози в кремнієвих детекторах товщиною від 300 мкм, розмірами (5×5)мм² и (1,8×1,8)мм², у діапазоні енергій падаючого γ–випромінювання від 5 кеВ до 10 МеВ. Рассмотрены основные преимущества применения кремниевых полупроводниковых детекторов в задачах дозиметрии по сравнению с традиционными детекторами. Проанализированы недостатки и предложены возможные методы их устранения. Один из предложенных методов позволяет увеличить эффективность регистрации гамма-квантов в диапазоне энергий 0,1…10 МэВ. Сформулированы требования, необходимые для оптимизации конструкции детекторов, работающих в широком диапазоне мощностей доз и энергии гамма–излучения, методом компьютерного моделирования. Проведенные математические расчеты и компьютерное моделирование определяют конструкцию дозиметра, материалы и толщину γ–конвертера. Приводятся механизмы моделирования поглощенной дозы в воздухе и амбиентной дозы в кремниевых детекторах толщиной от 300 мкм, размерами (5×5)мм² и (1,8×1,8)мм², в диапазоне энергий падающего γ–излучения от 5 кэВ до 10 МэВ.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/194575
citation_txt Modeling the response of a planar silicon detector when measuring the exposure dose rate in the energy range from 5 keV to 10MeV / V.N. Dubina, N.I. Maslov, I.N. Shlyahov // Problems of atomic science and tecnology. — 2020. — № 5. — С. 105-110. — Бібліогр.: 9 назв. — англ.
work_keys_str_mv AT dubinavn modelingtheresponseofaplanarsilicondetectorwhenmeasuringtheexposuredoserateintheenergyrangefrom5kevto10mev
AT maslovni modelingtheresponseofaplanarsilicondetectorwhenmeasuringtheexposuredoserateintheenergyrangefrom5kevto10mev
AT shlyahovin modelingtheresponseofaplanarsilicondetectorwhenmeasuringtheexposuredoserateintheenergyrangefrom5kevto10mev
AT dubinavn modelûvannâvídgukuplanarnogokremníêvogodetektoraprivimírûvannípotužnostíekspozicíinoídoziudíapazoníenergíivíd5kevdo10mev
AT maslovni modelûvannâvídgukuplanarnogokremníêvogodetektoraprivimírûvannípotužnostíekspozicíinoídoziudíapazoníenergíivíd5kevdo10mev
AT shlyahovin modelûvannâvídgukuplanarnogokremníêvogodetektoraprivimírûvannípotužnostíekspozicíinoídoziudíapazoníenergíivíd5kevdo10mev
AT dubinavn modelirovanieotklikaplanarnogokremnievogodetektorapriizmereniimoŝnostiékspozicionnoidozyvdiapazoneénergiiot5kévdo10mév
AT maslovni modelirovanieotklikaplanarnogokremnievogodetektorapriizmereniimoŝnostiékspozicionnoidozyvdiapazoneénergiiot5kévdo10mév
AT shlyahovin modelirovanieotklikaplanarnogokremnievogodetektorapriizmereniimoŝnostiékspozicionnoidozyvdiapazoneénergiiot5kévdo10mév
first_indexed 2025-12-01T00:40:28Z
last_indexed 2025-12-01T00:40:28Z
_version_ 1850858898019319808