Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable

The research of the distribution of the absorbed dose along the perimeter and length of the polymer protective sheath on the basis of a halogen-free composition depending on the technological dose of radiation exposure of shipboard cable samples was performed. It has been established that irregulari...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2019
Main Authors: Bezprozvannych, G.V., Mirchuk, I.A.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2019
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/195211
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable / G.V. Bezprozvannych, I.A. Mirchuk // Problems of atomic science and technology. — 2019. — № 5. — С. 44-48. — Бібліогр.: 15 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-195211
record_format dspace
spelling Bezprozvannych, G.V.
Mirchuk, I.A.
2023-12-03T15:27:32Z
2023-12-03T15:27:32Z
2019
Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable / G.V. Bezprozvannych, I.A. Mirchuk // Problems of atomic science and technology. — 2019. — № 5. — С. 44-48. — Бібліогр.: 15 назв. — англ.
1562-6016
https://nasplib.isofts.kiev.ua/handle/123456789/195211
553 (621.319)
The research of the distribution of the absorbed dose along the perimeter and length of the polymer protective sheath on the basis of a halogen-free composition depending on the technological dose of radiation exposure of shipboard cable samples was performed. It has been established that irregularity of irradiation around the cable perimeter can reach 20…30% with a technological dose in the range of 1.25…0.5. The irradiation along the cable is more uniform and does not exceed 5% at a technological dose in the range of 1.25…0.567. With a reduction in the technological dose, the irregularity of radiation around the perimeter and length of the cable increases. It is established that with an average absorbed dose of 210 kGy, the protective polymer shell does not meet the requirements of the standard for relative elongation at break. Optimal and physical-mechanical characteristics of the polymer shell made of halogen-free material are provided under irradiation in the range of the absorbed dose of 160 to 170 kGy.
Проведено дослідження розподілу поглиненої дози по периметру і довжині полімерної захисної оболонки на основі безгалогенного матеріалу в залежності від технологічної дози опромінення зразків суднових кабелів. Встановлено, що нерівномірність опромінення по периметру кабелю може досягати 20…30% при технологічній дозі в діапазоні 1,25…0,5. Опромінення вздовж кабелю є більш рівномірним і не перевищує 5% при технологічній дозі в інтервалі значень 1,25…0,567. При менших значеннях технологічної дози збільшується нерівномірність випромінювання по периметру і довжині кабелю. Встановлено, що при середній поглиненій дозі 210 кГр захисна полімерна оболонка не відповідає вимогам щодо відносного подовження при розриві. Оптимальні фізико-механічні характеристики полімерної оболонки з безгалогенного матеріалу забезпечуються при опроміненні в діапазоні поглиненої дози 160…170 кГр.
Выполнено исследование распределения поглощенной дозы по периметру и длине полимерной защитной оболочки на основе безгалогенной композиции в зависимости от технологической дозы радиационного облучения образцов судового кабеля. Установлено, что неравномерность облучения по периметру кабеля может достигать 20…30% при технологической дозе в диапазоне 1,25…0,5. Облучение кабеля по длине более равномерное и не превышает 5% при технологической дозе в интервале значений 1,25…0,567. При меньших значениях технологической дозы неравномерность облучения по периметру и длине кабеля увеличивается. Установлено, что при средней поглощенной дозе 210 кГр защитная полимерная оболочка не соответствует требованиям по относительному удлинению при разрыве. Оптимальные физико-механические характеристики полимерной оболочки из безгалогенного материала обеспечиваются при облучении в диапазоне поглощенной дозы 160…170 кГр.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Physics of radiation damages and effects in solids
Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
Розподіл поглиненої дози по периметру і довжині полімерної захисної оболонки при радіаційному опроміненні суднового кабелю
Распределение поглощенной дозы по периметру и длине полимерной защитной оболочки при радиационном облучении судового кабеля
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
spellingShingle Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
Bezprozvannych, G.V.
Mirchuk, I.A.
Physics of radiation damages and effects in solids
title_short Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
title_full Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
title_fullStr Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
title_full_unstemmed Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
title_sort distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable
author Bezprozvannych, G.V.
Mirchuk, I.A.
author_facet Bezprozvannych, G.V.
Mirchuk, I.A.
topic Physics of radiation damages and effects in solids
topic_facet Physics of radiation damages and effects in solids
publishDate 2019
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Розподіл поглиненої дози по периметру і довжині полімерної захисної оболонки при радіаційному опроміненні суднового кабелю
Распределение поглощенной дозы по периметру и длине полимерной защитной оболочки при радиационном облучении судового кабеля
description The research of the distribution of the absorbed dose along the perimeter and length of the polymer protective sheath on the basis of a halogen-free composition depending on the technological dose of radiation exposure of shipboard cable samples was performed. It has been established that irregularity of irradiation around the cable perimeter can reach 20…30% with a technological dose in the range of 1.25…0.5. The irradiation along the cable is more uniform and does not exceed 5% at a technological dose in the range of 1.25…0.567. With a reduction in the technological dose, the irregularity of radiation around the perimeter and length of the cable increases. It is established that with an average absorbed dose of 210 kGy, the protective polymer shell does not meet the requirements of the standard for relative elongation at break. Optimal and physical-mechanical characteristics of the polymer shell made of halogen-free material are provided under irradiation in the range of the absorbed dose of 160 to 170 kGy. Проведено дослідження розподілу поглиненої дози по периметру і довжині полімерної захисної оболонки на основі безгалогенного матеріалу в залежності від технологічної дози опромінення зразків суднових кабелів. Встановлено, що нерівномірність опромінення по периметру кабелю може досягати 20…30% при технологічній дозі в діапазоні 1,25…0,5. Опромінення вздовж кабелю є більш рівномірним і не перевищує 5% при технологічній дозі в інтервалі значень 1,25…0,567. При менших значеннях технологічної дози збільшується нерівномірність випромінювання по периметру і довжині кабелю. Встановлено, що при середній поглиненій дозі 210 кГр захисна полімерна оболонка не відповідає вимогам щодо відносного подовження при розриві. Оптимальні фізико-механічні характеристики полімерної оболонки з безгалогенного матеріалу забезпечуються при опроміненні в діапазоні поглиненої дози 160…170 кГр. Выполнено исследование распределения поглощенной дозы по периметру и длине полимерной защитной оболочки на основе безгалогенной композиции в зависимости от технологической дозы радиационного облучения образцов судового кабеля. Установлено, что неравномерность облучения по периметру кабеля может достигать 20…30% при технологической дозе в диапазоне 1,25…0,5. Облучение кабеля по длине более равномерное и не превышает 5% при технологической дозе в интервале значений 1,25…0,567. При меньших значениях технологической дозы неравномерность облучения по периметру и длине кабеля увеличивается. Установлено, что при средней поглощенной дозе 210 кГр защитная полимерная оболочка не соответствует требованиям по относительному удлинению при разрыве. Оптимальные физико-механические характеристики полимерной оболочки из безгалогенного материала обеспечиваются при облучении в диапазоне поглощенной дозы 160…170 кГр.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/195211
citation_txt Distribution of absorbed dose by the perimeter and the length of the polymeric protective sheath at radiacinous irradiation of the ship cable / G.V. Bezprozvannych, I.A. Mirchuk // Problems of atomic science and technology. — 2019. — № 5. — С. 44-48. — Бібліогр.: 15 назв. — англ.
work_keys_str_mv AT bezprozvannychgv distributionofabsorbeddosebytheperimeterandthelengthofthepolymericprotectivesheathatradiacinousirradiationoftheshipcable
AT mirchukia distributionofabsorbeddosebytheperimeterandthelengthofthepolymericprotectivesheathatradiacinousirradiationoftheshipcable
AT bezprozvannychgv rozpodílpoglinenoídozipoperimetruídovžinípolímernoízahisnoíobolonkipriradíacíinomuopromínennísudnovogokabelû
AT mirchukia rozpodílpoglinenoídozipoperimetruídovžinípolímernoízahisnoíobolonkipriradíacíinomuopromínennísudnovogokabelû
AT bezprozvannychgv raspredeleniepogloŝennoidozypoperimetruidlinepolimernoizaŝitnoioboločkipriradiacionnomoblučeniisudovogokabelâ
AT mirchukia raspredeleniepogloŝennoidozypoperimetruidlinepolimernoizaŝitnoioboločkipriradiacionnomoblučeniisudovogokabelâ
first_indexed 2025-11-30T11:50:40Z
last_indexed 2025-11-30T11:50:40Z
_version_ 1850857531570651136