Contribution of drift and diffusion to water capacity deionization

Drift and diffusion of ions in a cavity having the shape of oblate ellipsoid of revolution are considered. The obtained approximate relationship, between the time of drift and diffusion filling of deep cavity with ions, contains the applied voltage and the ratio of cavity size to the distance betwee...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2021
Hauptverfasser: Kudin, D.V., Ostroushko, V.M., Pashchenko, A.V., Rodionov, S.V., Yegorov, M.O., Zavada, L.M.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2021
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/195418
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Contribution of drift and diffusion to water capacity deionization / D.V. Kudin, V.M. Ostroushko, A.V. Pashchenko, S.V. Rodionov, M.O. Yegorov, L.M. Zavada // Problems of Atomic Science and Technology. — 2021. — № 4. — С. 162-165. — Бібліогр.: 7 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-195418
record_format dspace
spelling Kudin, D.V.
Ostroushko, V.M.
Pashchenko, A.V.
Rodionov, S.V.
Yegorov, M.O.
Zavada, L.M.
2023-12-05T10:05:11Z
2023-12-05T10:05:11Z
2021
Contribution of drift and diffusion to water capacity deionization / D.V. Kudin, V.M. Ostroushko, A.V. Pashchenko, S.V. Rodionov, M.O. Yegorov, L.M. Zavada // Problems of Atomic Science and Technology. — 2021. — № 4. — С. 162-165. — Бібліогр.: 7 назв. — англ.
1562-6016
PACS: 82.47.Uv
DOI: https://doi.org/10.46813/2021-134-162
https://nasplib.isofts.kiev.ua/handle/123456789/195418
Drift and diffusion of ions in a cavity having the shape of oblate ellipsoid of revolution are considered. The obtained approximate relationship, between the time of drift and diffusion filling of deep cavity with ions, contains the applied voltage and the ratio of cavity size to the distance between electrodes. It shows that in the performed experiments with the device for water capacitive deionization the filling of electrodes by ions was carried out, mainly, due to diffusion.
Розглянуто дрейф та дифузію іонів у порожнині, яка має форму сплюснутого еліпсоїду обертання. Отримане наближене співвідношення між часом дрейфового та дифузійного заповнення глибокої порожнини іонами містить докладену напругу та відношення розмірів порожнини до відстані між електродами та вказує, що у виконаних експериментах з пристроєм для ємнісної деіонізації води заповнення електродів іонами здійснювалося, переважно, через дифузію.
Рассмотрены дрейф и диффузия ионов в полости, которая имеет форму сплюснутого эллипсоида вращения. Полученное приближенное соотношение, между временами дрейфового и диффузионного заполнения глубокой полости ионами, содержит приложенное напряжение и отношение размеров полости к расстоянию между электродами и указывает, что в выполненных экспериментах с устройством для емкостной деионизации воды заполнение электродов ионами осуществлялось, в основном, через диффузию.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Gas discharge, plasma-beam discharge, and their applications
Contribution of drift and diffusion to water capacity deionization
Внесок дрейфу та дифузії в ємнісну деіонізацію води
Вклад дрейфа и диффузии в емкостную деионизацию воды
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Contribution of drift and diffusion to water capacity deionization
spellingShingle Contribution of drift and diffusion to water capacity deionization
Kudin, D.V.
Ostroushko, V.M.
Pashchenko, A.V.
Rodionov, S.V.
Yegorov, M.O.
Zavada, L.M.
Gas discharge, plasma-beam discharge, and their applications
title_short Contribution of drift and diffusion to water capacity deionization
title_full Contribution of drift and diffusion to water capacity deionization
title_fullStr Contribution of drift and diffusion to water capacity deionization
title_full_unstemmed Contribution of drift and diffusion to water capacity deionization
title_sort contribution of drift and diffusion to water capacity deionization
author Kudin, D.V.
Ostroushko, V.M.
Pashchenko, A.V.
Rodionov, S.V.
Yegorov, M.O.
Zavada, L.M.
author_facet Kudin, D.V.
Ostroushko, V.M.
Pashchenko, A.V.
Rodionov, S.V.
Yegorov, M.O.
Zavada, L.M.
topic Gas discharge, plasma-beam discharge, and their applications
topic_facet Gas discharge, plasma-beam discharge, and their applications
publishDate 2021
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Внесок дрейфу та дифузії в ємнісну деіонізацію води
Вклад дрейфа и диффузии в емкостную деионизацию воды
description Drift and diffusion of ions in a cavity having the shape of oblate ellipsoid of revolution are considered. The obtained approximate relationship, between the time of drift and diffusion filling of deep cavity with ions, contains the applied voltage and the ratio of cavity size to the distance between electrodes. It shows that in the performed experiments with the device for water capacitive deionization the filling of electrodes by ions was carried out, mainly, due to diffusion. Розглянуто дрейф та дифузію іонів у порожнині, яка має форму сплюснутого еліпсоїду обертання. Отримане наближене співвідношення між часом дрейфового та дифузійного заповнення глибокої порожнини іонами містить докладену напругу та відношення розмірів порожнини до відстані між електродами та вказує, що у виконаних експериментах з пристроєм для ємнісної деіонізації води заповнення електродів іонами здійснювалося, переважно, через дифузію. Рассмотрены дрейф и диффузия ионов в полости, которая имеет форму сплюснутого эллипсоида вращения. Полученное приближенное соотношение, между временами дрейфового и диффузионного заполнения глубокой полости ионами, содержит приложенное напряжение и отношение размеров полости к расстоянию между электродами и указывает, что в выполненных экспериментах с устройством для емкостной деионизации воды заполнение электродов ионами осуществлялось, в основном, через диффузию.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/195418
citation_txt Contribution of drift and diffusion to water capacity deionization / D.V. Kudin, V.M. Ostroushko, A.V. Pashchenko, S.V. Rodionov, M.O. Yegorov, L.M. Zavada // Problems of Atomic Science and Technology. — 2021. — № 4. — С. 162-165. — Бібліогр.: 7 назв. — англ.
work_keys_str_mv AT kudindv contributionofdriftanddiffusiontowatercapacitydeionization
AT ostroushkovm contributionofdriftanddiffusiontowatercapacitydeionization
AT pashchenkoav contributionofdriftanddiffusiontowatercapacitydeionization
AT rodionovsv contributionofdriftanddiffusiontowatercapacitydeionization
AT yegorovmo contributionofdriftanddiffusiontowatercapacitydeionization
AT zavadalm contributionofdriftanddiffusiontowatercapacitydeionization
AT kudindv vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT ostroushkovm vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT pashchenkoav vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT rodionovsv vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT yegorovmo vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT zavadalm vnesokdreifutadifuzíívêmnísnudeíonízacíûvodi
AT kudindv vkladdreifaidiffuziivemkostnuûdeionizaciûvody
AT ostroushkovm vkladdreifaidiffuziivemkostnuûdeionizaciûvody
AT pashchenkoav vkladdreifaidiffuziivemkostnuûdeionizaciûvody
AT rodionovsv vkladdreifaidiffuziivemkostnuûdeionizaciûvody
AT yegorovmo vkladdreifaidiffuziivemkostnuûdeionizaciûvody
AT zavadalm vkladdreifaidiffuziivemkostnuûdeionizaciûvody
first_indexed 2025-12-07T18:55:13Z
last_indexed 2025-12-07T18:55:13Z
_version_ 1850876848646389760