Influence of the magnetic field of the current passing through the anode on a glow discharge in a coaxial system

To study the influence of the magnetic field on the normal low-pressure glow discharge, an electrode coaxial system with a meshy tubular cathode and an internal anode was used. A current was passed through the anode to obtain the azimuthal magnetic field crossed with electric field. Oscillography of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Problems of Atomic Science and Technology
Datum:2022
Hauptverfasser: Melnichenko, M.S., Sydorenko, S.B., Kuzmichev, A.I., Maikut, S.O.
Format: Artikel
Sprache:Englisch
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2022
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/195897
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Influence of the magnetic field of the current passing through the anode on a glow discharge in a coaxial system / M.S. Melnichenko, S.B. Sydorenko, A.I. Kuzmichev, S.O. Maikut // Problems of Atomic Science and Technology. — 2022. — № 6. — С. 107-110. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:To study the influence of the magnetic field on the normal low-pressure glow discharge, an electrode coaxial system with a meshy tubular cathode and an internal anode was used. A current was passed through the anode to obtain the azimuthal magnetic field crossed with electric field. Oscillography of the signals from the electric probe and photodiode, together with video recording, made it possible to establish the movement of the discharge luminous region along the electrodes. When AC current with a frequency of 50 Hz was passed through the anode, the discharge movement was oscillatory – from one end of the system to another. Для дослідження впливу магнітного поля на нормальний тліючий розряд низького тиску використовували коаксіальну систему електродів із сітчастим трубчастим катодом і внутрішнім анодом, через який пропускали струм для отримання азимутального магнітного поля, схрещеного з електричним. Осцилографування сигналів з електричного зонда і фотодіода спільно з відеозйомкою дозволило встановити рух області розрядної зони, що світиться, вздовж електродів. При пропусканні змінного струму частотою 50 Гц через анод рух розряду був коливальним – від одного торця системи до іншого.
ISSN:1562-6016