The use of CCCM for the creation of the high-temperature detectors of the water wapor

A technique for assessing the presence of water vapor in a mixture using high-temperature detectors made of carbon-carbon composite material (CCCM) is proposed. The change in the electrical resistance of CCCM in a mixture containing water vapor at a temperature of 1000 °C is presented. The efficienc...