Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке

Saved in:
Bibliographic Details
Published in:Проблемы криобиологии
Date:2012
Main Authors: Оверко, А.Н., Грошевой, М.И., Чижевский, В.В.
Format: Article
Language:Russian
Published: Інститут проблем кріобіології і кріомедицини НАН України 2012
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/68620
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке / А.Н. Оверко, М.И. Грошевой, В.В. Чижевский // Проблемы криобиологии. — 2012. — Т. 22, № 3. — С. 330. — рос., англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1859898855671201792
author Оверко, А.Н.
Грошевой, М.И.
Чижевский, В.В.
author_facet Оверко, А.Н.
Грошевой, М.И.
Чижевский, В.В.
citation_txt Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке / А.Н. Оверко, М.И. Грошевой, В.В. Чижевский // Проблемы криобиологии. — 2012. — Т. 22, № 3. — С. 330. — рос., англ.
collection DSpace DC
container_title Проблемы криобиологии
first_indexed 2025-12-07T15:56:09Z
format Article
fulltext Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке А.Н. ОВЕРКО, М.И. ГРОШЕВОЙ, В.В. ЧИЖЕВСКИЙ Институт проблем криобиологии и криомедицины НАН Украины, г. Харьков Use of Liquid Nitrogen Level Alarm System to Optimize Conditions of Biological Material Storage at Low Temperature Bank A.N. OVERKO, M.I. GROSHEVOY, V.V. CHIZHEVSKY Institute for Problems of Cryobiology and Cryomedicine of the National Academy of Sciences of Ukraine, Kharkov, Ukraine В низкотемпературном банке (НТБ), наряду с науч- ными задачами относительно замораживания живых объектов, возникают научно-технические задачи прак- тического характера по обеспечению полноценного хра- нения криоконсервированных биообъектов. Для оптимизации условий хранения биологического материала в НТБ используется автоматизированная сис- тема контроля температуры и уровня жидкого азота в криохранилищах – СКК-1. Однако, согласно регламенту работы, при проведении заправки хранилищ банка хладо- носителем, данная система должна отключаться. По- этому целесообразно создать и использовать систему сигнализации азотного уровня (САУ), задачей которой являлось бы отслеживание уровня жидкого азота в крио- хранилищах непосредственно в процессе заправки. Нами разработан САУ, принцип измерения которого основан на отличии эффективности отвода тепла жид- костью и газом. Известно, что при погружении терморе- зистора в жидкий азот его температура быстро сни- жается до –196°С. В то же время при нахождении в парах азота температура датчика повышается, а его сопротив- ление снижается. Прибор состоит из контрольного блока снаружи крио- хранилища и металлической рейки, в которой равномер- но размещены 10 датчиков. Рейка с датчиками установ- лена между внутренней стенкой хранилища и поворот- ным стеллажом. Данный вариант размещения датчиков не мешает при работе с биоматериалом, а также не пов- реждается при заправке. Состояние (пар/жидкость) каждого датчика отобра- жается светодиодом на контрольном блоке, свечение диода указывает на то, что соответствующий датчик на- ходится в жидкости. В результате на контрольном блоке светодиодами отображается наполняемость хранилища с шагом 10% от общей ёмкости хранилища. Внедрение данной системы сигнализации во всех хра- нилищах банка позволит контролировать процесс за- правки криохранилищ жидким азотом, а также облегчит и обезопасит работу оператора. 330 At low temperature bank (LTB) along with scientific tasks as for freezing of living objects there are appeared the R&D tasks of practical character on providing the integral storage of cryopreserved biological objects. To optimize the storage conditions of biological material in the LTB there are used the automated system of tempe- rature and liquid nitrogen level control in SKK-1 cryotanks. However, according to the exploitation protocol when per- forming filling in of the tanks with cooling agent this sys- tem should be turned-off. Therefore it is expedient to create and use the nitrogen level alarm system (NLAS), the task of which would be the tracing the liquid nitrogen level in cryo- tanks directly during the filling. We have designed the NLAS the operating principle of which is based on the difference of efficiency of heat transfer in liquid and gas. It is known that when plunging the thermal resistor into liquid nitrogen its temperature reduces rapidly down to –196°C. At the same time being in nitrogen vapors the gauge temperature increases and its resistance reduces. The device consists of the control block outside the cryotank and metal strip wherein 10 gauges are evenly set. The strip with gauges is adjusted between the inner wall of the depot and revolving shelves. This variant of gauges location does not interfere when working with biological materials as well as is not damaged during filling. The state (vapor/liquid) of each gauge is shown by light diode at the control block, diode lightening means that cor- responding gauge is in liquid. As a result at the control block the fill rate of the tank (each light diode corresponds to the 1/10th of the depot filling capacity) is shown. Introduction of this alarm system in all the tanks of the bank allows the control of the filling process of cryotanks with liquid nitrogen and also will facilitate and make safer the operating person work. problems of cryobiology Vol. 22, 2012, №3 проблемы криобиологии Т. 22, 2012, №3
id nasplib_isofts_kiev_ua-123456789-68620
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 0233-7673
language Russian
last_indexed 2025-12-07T15:56:09Z
publishDate 2012
publisher Інститут проблем кріобіології і кріомедицини НАН України
record_format dspace
spelling Оверко, А.Н.
Грошевой, М.И.
Чижевский, В.В.
2014-09-26T17:48:11Z
2014-09-26T17:48:11Z
2012
Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке / А.Н. Оверко, М.И. Грошевой, В.В. Чижевский // Проблемы криобиологии. — 2012. — Т. 22, № 3. — С. 330. — рос., англ.
0233-7673
https://nasplib.isofts.kiev.ua/handle/123456789/68620
ru
Інститут проблем кріобіології і кріомедицини НАН України
Проблемы криобиологии
Стендовые доклады
Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
Use of Liquid Nitrogen Level Alarm System to Optimize Conditions of Biological Material Storage at Low Temperature Bank
Article
published earlier
spellingShingle Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
Оверко, А.Н.
Грошевой, М.И.
Чижевский, В.В.
Стендовые доклады
title Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
title_alt Use of Liquid Nitrogen Level Alarm System to Optimize Conditions of Biological Material Storage at Low Temperature Bank
title_full Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
title_fullStr Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
title_full_unstemmed Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
title_short Использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
title_sort использование системы сигнализации уровня жидкого азота для оптимизации условий хранения биологического материала в низкотемпературном банке
topic Стендовые доклады
topic_facet Стендовые доклады
url https://nasplib.isofts.kiev.ua/handle/123456789/68620
work_keys_str_mv AT overkoan ispolʹzovaniesistemysignalizaciiurovnâžidkogoazotadlâoptimizaciiusloviihraneniâbiologičeskogomaterialavnizkotemperaturnombanke
AT groševoimi ispolʹzovaniesistemysignalizaciiurovnâžidkogoazotadlâoptimizaciiusloviihraneniâbiologičeskogomaterialavnizkotemperaturnombanke
AT čiževskiivv ispolʹzovaniesistemysignalizaciiurovnâžidkogoazotadlâoptimizaciiusloviihraneniâbiologičeskogomaterialavnizkotemperaturnombanke
AT overkoan useofliquidnitrogenlevelalarmsystemtooptimizeconditionsofbiologicalmaterialstorageatlowtemperaturebank
AT groševoimi useofliquidnitrogenlevelalarmsystemtooptimizeconditionsofbiologicalmaterialstorageatlowtemperaturebank
AT čiževskiivv useofliquidnitrogenlevelalarmsystemtooptimizeconditionsofbiologicalmaterialstorageatlowtemperaturebank